INSTALLATION
TOOLS
INSTRUCTIONS
PARTS
DIMENSIONS
IMPORTANT ADDITIONAL INFORMATION
DESCRIPTION
This macerator is (manufactured in a factory that is quality) certified to ISO 9001. Installed and used correctly, the unit will give consistent and reliable service.
This device is not designed for persons (including children) with limited physical, sensory or mental abilities, or those with minimal experience and knowledge, unless they are monitored and are given the necessary instructions for using the device, with the help of a person responsible for their safety. Monitor children and make sure they do not play with the device.
APPLICATIONS
This appliance is a compact lift pump unit designed for removing wastewater from a horizontal outlet toilet, shower, bidet or washbasin (*: depending on the model). This appliance conforms to EN 12050-3 and the European standards concerning Electrical safety and electromagnetic compatibility..
INSTALLATION
The unit should be accessible for possible service. The fitting and working of your appliance must meet local regulations and the EN 12056-4 standard. To optimize the latest technical developments concerning soundproofing incorporated into this unit, it is important to:
- position the WC pan so that it is not in contact with a partition or wall of the room
- place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient
- fix the discharge pipe correctly, with distances of not more than one meter between the fastenings.
CONNECTION TO THE ELECTRICAL SUPPLY
The electrical installation should be carried out by a qualified person. The unit requires a 220/240V single phase AC 50 Hz supply (UK specification). The power supply circuit of the appliance must be earthed (Class I) and protected by a GFCI high sensitivity (30mA). Warning: Ensure the electricity is turned OFF at the main switchboard before wiring to the connector. All wiring must conform to BS7671, 1992 requirements for electrical installations. Do not connect the unit to a conventional plug and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The wires in the mains lead are colored in accordance with the following code:
- Brown – Live
- Blue – Neutral
- Green/Yellow – Earth
The connection must be used exclusively to power the device. All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. Please do not cut/ shorten the electrical supply cable which can make it very difficult to remove in the event of a service requirement.
COMMISSIONING THE UNIT
Flush the WC checking that all seals and connections are watertight. Check both the discharge pipework from the unit and the other sanitary appliances connections. Check the watertightness of connections to sanitary appliances:
- toilet
- shower bidet
- washbasin(: depending on the model).
MAINTENANCE
WARNING: In the event of prolonged absence it is essential to turn off the water supply to protect the installation against sub-zero temperatures.
CARE OF YOUR UNIT
- In order to remove the scale and clean the macerator and the bowl, use the SANIFLO Cleanser/Descent.
- Disconnect the macerator power supply,
- Pour an amount of cleanser into the pan
- Leave it to stand for 1 or 2 hours,
- Re-connect the macerator power supply,
- Rinse by operating the flushing system twice.
- Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water.
FAULT FINDING / REMEDIES
IN ALL CASES, YOU MUST DISCONNECT THE MACERATOR FROM THE POWER SUPPLY
GUARANTEE
2 years guarantee from its date of purchase subject to correct installation and correct use. Only the disposal of toilet paper, fecal matter, and wastewater will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids, and other chemicals can also cause damage to the unit and will invalidate the guarantee.
UNITED KINGDOM
SANIFLO Ltd.,
- address: Howard House, The Runway South Ruislip Middx., HA4 6 SE
- Tel: +44 208 842 0033
- Fax: +44 208 842 1671