SFA SANIPACK /SANINSIDE Installation Guide

June 5, 2024
SFA

SFA SANIPACK SANINSIDE LOGO

SFA SANIPACK SANINSIDE

PARTS OVERVIEW

SFA SANIPACK SANINSIDE 12

FIXATION PROCEDURE

SFA SANIPACK SANINSIDE 4

SFA SANIPACK SANINSIDE 9

SFA SANIPACK SANINSIDE 10

DESCRIPTION

SFA SANIPACK SANINSIDE1

This macerator is manufactured in a fac-tory which is quality certified to ISO 9001. Installed and used correctly, the unit will give consistent and reliable service.This device is not designed for persons including children with limited physical, sensory or mental abilities, or those with minimal experience and knowledge, unless they are monitored and are given the necessary instructions for using the device, with the help of a person responsible for their safety. Monitor children and make sure they do not play with the device.

APPLICATIONS

This appliance is a compact lift pump unit designed for removing waste water from a horizontal outlet toilet, shower, bidet or washbasin depending on the model. This appliance conforms to EN 12050-3 and the European standards concerning electrical safety and electromagnetic compatibility.

INSTALLATION

SFA SANIPACK SANINSIDE2

The unit should be accessible for possible service. The fitting and working of your appliance must meet local regulations and the EN 12056-4 standard. To optimise the latest technical develop ments concerning soundproofing incorpo- rated into this unit, it is important to contact with a partition or wall of the room surface to ensure that the resilient mounts are fully efficient distances of not more than one metre between the fastenings.

CONNECTION TO THE ELECTRICAL SUPPLY

SFA SANIPACK SANINSIDE 13

The electrical installation should be carried out by a qualified person. The unit requires a 220/240V single phase AC 50 Hz supply (UK specification).
The power supply circuit of the ap-pliance must be earthed Class I and protected by a GFCI high sensitivity 30mA

Warning
Ensure the electri-city is turned OFF at the main switch board before wiring to connector. All wiring must conform to BS7671  connect the unit to a conventional plug and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The wires in the mains lead are coloured in accordance with  the following code

  • Brown  Live.
  • Blue  Neutral.
  • Green/Yellow  Earth.

The connection must be used exclusively to power the device. All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. Please do not cut/shorten the electrical supply cable which can make it very difficult to remove in the event of a service requirement.

COMMISSIONING THE UNIT

Flush the WC checking that all seals, and connections are watertight. Check both the discharge pipework from the unit and the other sanitary appliances connections. Check the watertightness of connections to sanitary appliances toilet, shower, bidet or washbasin  depending on the model.

MAINTENANCE

WARNING
In the event of prolonged absence it is essential to turn off the water supply to protect the installation against sub zero temperatures.

CARE OF YOUR UNIT

In order to remove scale and clean the macerator and the bowl, use the SANIFLO Pour an amount of cleanser into the pan.

  • Leave it to stand for 1 or 2 hours.
  • Re connect the macerator power supply.
  • Rinse by operating the flushing system twice.
  • Carry out the operation once every 3 months on average but the frequency may need to be changed depending on the hardness of the water.

FAULT FINDING / REMEDIES

IN ALL CASES, YOU MUST DISCONNECT THE MACERATOR FROM THE POWER SUPPLY

SYMPTOMS

SYMPTOMS

MOTOR DOES NOT ACTIVATE
MOTOR EMITS A RATTLING OR

crunching sound, hums, but

does not run

MOTOR INTERMITTENTLY

activates

MOTOR OPERATES NORMALLY BUT

continues to run for a long time

UNIT STOPS
OTOR IS SURGING AND WATER

in the WC pan goes down

very slowly

LOUDY WATER COMES UP INTO

the shower basin units with side inlets

PROBABLE CAUSES

PROBABLE CAUSES

ELECTRICAL POWER SUPPLY IS NOT ACTIVE

ELECTRICAL POWER SUPPLY IS DEFECTIVE

MOTOR OR THE CONTROL SYSTEM

IS DEFECTIVE

Foreign object into the box

P ROBLEM WITH THE MOTOR OR THE

CONTROL SYSTEM

CONNECTED SANITARY DEVICES ARE DRIPPING WATER

NON RETURN VALVE IS FAULTY

LENGTH OR HEIGHT OF THE I NSTALLATION IS OVER THE SPECIlCATION, OR THERE ARE TOO MANY BENDS!ELBOWS

PUMP COVER P LATE IS PARTIALLY

OBSCURED!BLOCKED

UNIT HAS BEEN RUNNING FOR TOO LONG (THERMAL CUT OUT
AIR DISPENSER IS CLOGGED UP s 0ROBLEM WITH MOTOR
HOWER INSTALLED TOO LOW AS COMPARED WITH THE MACERATOR UNIT

INGED SIDE INLET DISCS CLOGGED U P

REMEDIES

REMEDIES

RESTORE THE ELECTRICAL SUPPLY

CHECK THE ELECTRICAL POWER

supply

OTHERWISE ASK AN APPROVED

repair agent to intervene

REMOVE THE FOREIGN BODY

OTHERWISE ASK AN APPROVED

repair agent to intervene

OHECK THE INSTALLATION UPSTREAM

LEAN OR REPLACE THE NON RETURN

valve

CHECK THE INSTALLATION

OTHERWISE ASK AN APPROVED

repair agent to intervene

AIT FOR RESET  THEN ASK AN

approved repair agent to

intervene

CLEAR THE AIR RELIEF HOLE

OTHERWISE ASK AN APPROVED

repair agent to intervene

CHECK THE INSTALLATION

CLEAN THE HINGED DISCS

OTHERWISE ASK AN APPROVED

repair agent to intervene

GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation and correct use.Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sani-tary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids and other chemicals can also cause damage to the unit, and will invalidate the guarantee.