AUDIBAX Joliet 100FC Zoom User Manual
- June 3, 2024
- AUDIBAX
Table of Contents
Joliet 100FC Zoom
User Manual
Joliet 100FC Zoom
Please read the manual before using the product
Caution!
| Be careful with your operations. With a dangerous voltage you can suffer a
dangerous electric shock when touching the wires!
---|---
| Avoid looking directly into the light source!
Wear protective glasses and other PPE (personal protective equipment) when
working on or near the fixture.
| Always make sure you are connecting this product to the proper voltage in
accordance with the specifications in this manual or on the product’s
specification label. Make sure it is grounded when using it!
Unplug mains lead before opening the housing!
Make sure that the power cord is never crimped or damaged by sharp edges.
Check the fixture and the power cord from time to time.
Make sure to replace the fuse with another of the same type and rating.
| For your own safety, please read this user manual carefully before your
initial start-up.
Follow operating safety precautions and pay attention to warning signs methods
and equipment on the user manual.
| Warning! This symbol indicates a hot surface. Certain parts of the housing
can become hot during operation. After use, wait for a cool-down period of at
least 10 minutes before handling or transporting the device.
| Indoor use only! To prevent risk of fire or shock, do not expose this
product to rain or moisture. IP 20 rating.
The ambient temperature must always be between -5° C and +45° C.
Every person involved with the installation, operation and maintenance of this
device has to
– Be qualified
– Follow the instructions of this manual
– Consider this manual to be part of the total product
– Keep this manual for the entire service life of the product
– Pass this manual on to every further owner or user of the product
– Download the latest version of the user manual from the Internet
Introduction
Thank you for having chosen Joliet 100FC Zoom. You will see you acquired a
powerful and versatile device.
Unpack your item. Before your initial start-up, please make sure that there is
no damage caused by transportation. Should there be any, consult your dealer
and do not use the
device.
Safety instructions
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Always disconnect from the mains, when the device is not in use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by authorized dealers Overview
Installation
Read ‘Safety information’ before installing the fixture.
The fixture is designed for indoor use only and must be used in a dry location
with adequate ventilation. Ensure that none of the fixture’s ventilation slots
are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a
surface or leave it where it can be moved or fall over. If you install the
fixture in a location where it may cause injury or damage if it falls, secure
it as directed in this user manual using a securely anchored safety cable that
will hold the fixture if the primary fastening method fails.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface that is oriented at
any angle. Ensure that the surface and all fasteners used can support at least
10 times the weight of all fixtures and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it
can be moved or fall over. If you install the fixture in a location where it
may cause injury or damage if it falls, secure it as directed below with a
securely anchored safety cable that will hold the fixture if the primary
fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any
orientation. When installing the fixture hanging vertically down, you can use
an open-type clamp such as a G-clamp. When installing in any other
orientation, you must use a half-coupler clamp that completely encircles the
truss chord.
To clamp the fixture to a truss:
- Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it.
- Block access under the work area.
- Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting bracket legs and be fastened with a self-locking nut.
- Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp securely.
- Secure the fixture with a safety cable as directed below.
Securing with a safety cable
Secure the fixture with a safety cable (or other secondary attachment) that is
approved for the weight of the fixture so that the safety cable will hold the
fixture if a primary attachment fails.
Loop the safety cable through the eyebolt in the back of the fixture and
around a secure anchoring point. Do not loop the safety cable around the
fixture’s mounting bracket only, as this will leave the fixture unsecured if
it separates from the bracket.
DMX-512 connection/connection between fixtures
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-
output of the controller directly with the DMX-input of the first fixture in
the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs,
you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-
input of the next fixture. Always connect one output with the input of the
next fixture until all fixtures are connected.
DMX-512 connection with DMX terminator :
For installations where the DMX cable has to run a long distance or is in an
electrically noisy environment, such as in a discotheque, it is recommended to
use a DMX terminator. This helps in preventing corruption of the digital
control signal by electrical noise. The DMX terminator is simply an XLR plug
with a 120 resistor connected between pins 2 and 3, which is then plugged into
the output XLR socket of the last fixture in the chain.
Caution: At the last fixture, the DMX-cable has to be terminated with a
terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a
3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Power connection
Power Requirements
The Joliet 100FC Zoom luminaire operates on 100 to 240 volts AC (+/- 10%,
auto-ranging). The luminaire contains an auto-ranging power supply.
Power linking between fixtures:
The fixture with powercon in and out socket. Connect the power out to the
power in socket in the next fixture till all are connected.
Caution: maximum power linking – 8 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below:
Cable color | Connection | International |
---|---|---|
Brown | Live | L |
Blue | Neutral | N |
Yellow/green | Earth(Ground) |
Operation
The Joliet 100FC zoom can operate different modes. In each mode you can run
the fixture as a standalone fixture or in a master/slave configuration. This
next section will detail the differences in the operating modes.
Control Menu Map
MENU | SUB MENU | OPERATION |
---|---|---|
Addr | d001-d512 | RDM/DMX address |
CHnL | Stag(12CH) | Channel mode |
ArC.1(3CH)
Ar1.d(4CH)
ArC.2(4CH)
Ar2.d(5CH)
Ar2.S(6CH)
HSV(3CH)
SP–| T.(00-99)| Auto program speed increasing
Pr–| Pr01~Pr10| Auto programs
CoLo| C.(01~15)| Color preset
Sens| S.(000-100)| Sound sensitivity
Strb| S.01-s.20| Strobe with spead increasing
rL–| r.(000-255)| Red dimmer
gL–| g.(000-255)| Green dimmer
bL–| b.(000-255)| Blue dimmer
uL–| u.(000-255)| White dimmer
Focu| F.(000-255)| Zoom
nodE| nod.0| Dimmer speed 0 (no delay)
nod.1| Dimmer speed 1
nod.2| Dimmer speed 2
nod.3| Dimmer speed 3
nod.4| Dimmer speed 4 (slowest speed)
Id| Id.01-Id.66| ID address setting
tEnP| -25~100| Fixture temperature
UErn| | Firmware version
rSEt| yes/no| Reset
pnnF| (1.2~24.0)F| PWM refresh rate adjustment(KHz)
Addressing
All fixtures should be given a DMX starting address when using a DMX signal,
so that the correct fixture responds to the correct control signals. This
digital starting address is the channel number from which the fixture starts
to listen to the digital control information sent out from the DMX controller.
The allocation of this starting address is achieved by setting the correct
number on the display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures,
or make different address for each fixture individually.
If you set the same address, all the units will start to listen to the same
control signal from the same channel number. In other words, changing the
settings of one channel will affect all the fixtures simultaneously.
If you set a different address, each unit will start to listen to the channel
number you have set, based on the quantity of control channels of the unit.
That means changing the settings of one channel will affect only the selected
fixture.
In the case of the Joliet 100FC Zoom, which is 3/4/5/6/12 channels fixture. If
you set, for example, the address in the 3 channel mode to channel 4, the
device will use the channel 4 to 7 for control.
Universal DMX Control
This function allows you to use a universal DMX-512 controller to control the
dimmer and strobe. A DMX controller allows you to create unique programs
tailored to your individual needs.
RDM control
The Joliet 100FC Zoom can communicate using RDM (Remote Device Management) in
accordance with ESTA’s American National Standard E1.20-2006: Entertainment
Technology RDM Remote Device Management over DMX512 Networks.
RDM is a bi-directional communications protocol for use in DMX512 control
systems; it is the open standard for DMX512 device configuration and status
monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream
without affecting existing non-RDM equipment. It allows a console or dedicated
RDM controller to send commands to and receive messages from specific
fixtures.
With RDM function, you can set the DMX address of your fixtures remotely. This
is especially useful when the device is installed in a remote area.
Each Joliet 100FC Zoom has a factory set RDM UID (unique identification
number).
DMX Protocol
STAG
12 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Red | 000-255: 0-100% Red dimmer |
CH3 | Green | 000-255: 0-100% Green dimmer |
--- | --- | --- |
CH4 | Blue | 000-255: 0-100% Blue dimmer |
CH5 | White | 000-255: 0-100% White dimmer |
CH6 | Color preset & color temp | 000-010: No function |
011-030: Red 100%, Green0-100%, Blue 0%
031-050: Red 100-0%, Green 100%, Blue 0%
051-070: Red 0%, Green 100%, Blue 0-100%
071-090: Red 0%, Green 100-0%, Blue 100%
091-110: Red 0~100%, Green 0%, Blue 100%
111-130: Red 100%, Green 0%, Blue 100-0%
131-150: Red 100%, Green 0-100%, Blue 0-100%
151-170: Red 100-0%, Green 100-0%, Blue 100%
171-200: Red 100%, Green 100%, Blue 100%
201-220: Colour temperature1 3200K
220-255: Colour temperature2 5600K
CH7| Strobe| 000-013: Strobe off
014-255: Strobe with speed increasing
CH8| Zoom| 000-255: Zoom function
CH9| Auto program| 000-020: no function
021-030: Auto1
031-040: Auto2
041-050: Auto3
051-060: Auto4
061-070: Auto5
071-080: Auto6
081-090: Auto7
091-100: Auto8
101-110: Auto9
111-120: Auto10
121-255: No function
CH10| Auto program speed| 000-255: Speed increasing
CH11| Dimmer mode| 000-005: Menu setting
006-055: Dimmer speed 0 (no delay)
056-105: Dimmer speed 1
106-155: Dimmer speed 2
156-205: Dimmer speed 3
206-255: Dimmer speed 4 (slowest speed)
CH12| ID address setting| 000-009: ID1-ID66
---|---|---
010-019: ID1
020-029: ID2
030-039: ID3
…
200-209: ID20
210: ID21
211: ID22
…
255: ID66
ARC:1
3 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Red | 000-255: 0-100% Red dimmer |
CH2 | Green | 000-255: 0-100% Green dimmer |
CH3 | Blue | 000-255: 0-100% Blue dimmer |
AR1:D
4 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Red | 000-255: 0-100% Red dimmer |
CH3 | Green | 000-255: 0-100% Green dimmer |
CH4 | Blue | 000-255: 0-100% Blue dimmer |
ARC:2
4 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Red | 000-255: 0-100% Red dimmer |
CH2 | Green | 000-255: 0-100% Green dimmer |
CH3 | Blue | 000-255: 0-100% Blue dimmer |
CH4 | White | 000-255: 0-100% White dimmer |
AR2:D
5 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Red | 000-255: 0-100% Red dimmer |
CH3 | Green | 000-255: 0-100% Green dimmer |
CH4 | Blue | 000-255: 0-100% Blue dimmer |
CH5 | White | 000-255: 0-100% White dimmer |
AR2: S
6 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Red | 000-255: 0-100% Red dimmer |
CH3 | Green | 000-255: 0-100% Green dimmer |
CH4 | Blue | 000-255: 0-100% Blue dimmer |
CH5 | White | 000-255: 0-100% White dimmer |
CH6 | Strobe | 000-255: Strobe with speed increasing |
HSV
3 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Hue | 000-255: 0-100% Hue |
CH2 | Saturation | 000-255: 0-100% Saturation |
CH3 | Value(brightness) | 000-255: 0-100% Value(brightness) |
ID address selection (Stag-12 channels mode)
Each independent DMX address can have up to 66 ID addressed fixtures. An ID
address of 0 will activate all ID address locations.
CH12 in Stag-12 CH mode is used to select the target ID address.
DMX value| Function| | DMX value| Function| | DMX
value| Function
---|---|---|---|---|---|---|---
000-009| ID1-ID66| | 212| ID23| | 235| ID46
010-019| ID1| 213| ID24| 236| ID47
020-029| ID2| 214| ID25| 237| ID48
030-039| ID3| 215| ID26| 238| ID49
040-049| ID4| 216| ID27| 239| ID50
050-059| ID5| 217| ID28| 240| ID51
060-069| ID6| 218| ID29| 241| ID52
070-079| ID7| 219| ID30| 242| ID53
080-089| ID8| 220| ID31| 243| ID54
090-099| ID9| 221| ID32| 244| ID55
100-109| ID10| 222| ID33| 245| ID56
110-119| ID11| 223| ID34| 246| ID57
120-129| ID12| 224| ID35| 247| ID58
130-139| ID13| 225| ID36| 248| ID59
140-149| ID14| 226| ID37| 249| ID60
150-159| ID15| 227| ID38| 250| ID61
160-169| ID16| 228| ID39| 251| ID62
170-179| ID17| 229| ID40| 252| ID63
180-189| ID18| 230| ID41| 253| ID64
190-199| ID19| 231| ID42| 254| ID65
200-209| ID20| 232| ID43| 255| ID66
210| ID21| 233| ID44| |
211| ID22| 234| ID45| |
Fixture Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical
lenses and mirror should be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates
(I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning
on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
To clean the fixture:
- Disconnect the fixture from power and allow it to cool for at least 10 minutes.
- Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure compressed air.
- Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water.
- Check that the fixture is dry before reapplying power.
Fuse Replacement
This fuse is located in a fuseholder next to the MAINS OUT socket on the
connections panel.
To replace a fuse:
- Disconnect the fixture from power and allow it to cool for at least 10 minutes.
- Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and rating only.
- Reinstall the fuseholder cap before reapplying power.
Troubleshooting
Listed below are a few common problems that you may encounter, with solutions.
The fixture does not work, no light
- Check the connection of power and main fuse. Be sure the external fuse has not blown.
- Measure the mains voltage on the main connector.
Technical specifications
Model | Joilet 100FC Zoom |
---|---|
Power supply: | AC100-240V, 50/60Hz |
Light source: | 100W LED |
Color mixing: | RGBW color mixing |
Zoom scale: | 25° – 65° motorized |
Power connection: | PowerCON in&out |
Maximum power linking: | 8 units |
Signal connection: | 3-pin XLR in&out(5-pin optional) |
DMX channels: | ARC.1(3CH), AR1.D(4CH), ARC.2(4CH), AR2.D(5CH), AR2.S(6CH), |
HSV(3CH), STAG(12CH)
Control mode:| RDM, DMX, Master-slave
Housing:| Colour black, Aluminum
Size(barn door excluded):| 331 x 210 x 345.7mm(13 x 8.3 x 13.6in)
Package(carton):| 448 x 338 x 400mm(17.6 x 13.3 x 15.7in)
N.W.:| 6.6 kg(14.5 lb)
Environment:| IP20
Please note: All information is subject to change without prior notice. 13.11.2018
Read User Manual Online (PDF format)