CooperVision BIOFINITY Soft Hydrophilic Contact Lenses Instructions
- June 4, 2024
- CooperVision
Table of Contents
Soft Hydrophilic Contact Lenses
Instructions Manual
BIOFINITY® (comfilcon A)
Soft (Hydrophilic) Contact Lenses For Planned Replacement
IMPORTANT: Please read carefully and keep this information for future use.
This package insert is intended for the Eye Care Practitioner but should be
made available to patients upon request. The Eye Care Practitioner should
provide the patient with the patient instructions that pertain to the
patient’s prescribed lens.
SYMBOLS KEY
Soft Hydrophilic Contact Lenses Instructions
SYMBOL | DEFINITION | Reference |
---|---|---|
Caution: Federal (USA) law restricts this device to sold by or on the order | ||
of a licensed practitioner | 81 FR 38911 | |
Caution / See Instructions for Wearers | BS EN ISO 15223-1 |
Table 1, Symbol 5.4.4
| Use by Date (expiration date)| BS EN ISO 15223-1
Table 1, Symbol 5.1.4
| Batch Code| BS EN ISO 15223-1
Table 1, Symbol 5.1.5
| Sterile using Steam Heat| BS EN ISO 15223-1
Table 1, Symbol 5.2.5
| Manufacturer| BS EN ISO 15223-1
Table 1, Symbol 5.1.1
| Authorized representative in the European Community| BS EN ISO 15223-1
Table 1, Symbol 5.1.2
| Do not use it if the package is damaged| BS EN ISO 15223-1
Table 1, Symbol 5.2.8
| Consult instructions for use/consult electronic instructions for use|
BS EN ISO 15223-1
Table 1, Symbol 5.4.3
| Date of manufacture| BS EN ISO 15223-1
Table 1, Symbol 5.1.3
CAUTION: FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A LICENSED PRACTITIONER.
DESCRIPTION
BIOFINITY (comfilcon A) contact lenses are available as spheric, aspheric,
toric, multifocal, and toric multifocal lens designs.
The lenses are made from a material containing 48% water and 52% comfilcon A,
a silicone-containing hydrogel. The lenses have a tint (phthalocyanine blue)
which is added to make the lens more visible for handling.
BIOFINITY and BIOFINITY XR SPHERE (comfilcon A) contact lens
parameters:
- Diameter: 13.5 mm to 15.0 mm
- Base Curve: 8.0 mm to 9.5 mm
- Center Thickness: 0.065 mm to 0.60 mm (varies with power)
- Powers: -20.00 D to +20.00 D
BIOFINITY ENERGYS™ ASPHERE (comfilcon A) contact lens parameters:
- Diameter: 13.5 mm to 15.0 mm
- Base Curve: 8.0 mm to 9.5 mm
- Center Thickness: 0.065 mm to 0.60 mm (varies with power)
- Powers: -20.00 D to +20.00 D
BIOFINITY TORIC (comfilcon A) and BIOFINITY XR TORIC (comfilcon A) contact lens parameters:
- Diameter: 13.5 mm to 15.0 mm
- Base Curve: 8.0 mm to 9.5 mm
- Center Thickness: 0.07 mm to 0.60 mm (varies with power)
- Powers: -20.00 D to +20.00 D
- Cylinder: -0.25 D to -5.75 D
- Axis: 0° to 180°
BIOFINITY MULTIFOCAL (comfilcon A) and BIOFINITY XR MULTIFOCAL (comfilcon A) contact lens parameters:
- Diameter: 13.5 mm to 15.0 mm
- Base Curve: 8.0 mm to 9.5 mm
- Center Thickness: 0.08 mm to 0.60 mm (varies with power)
- Powers: -20.00 D to +20.0 D
- Addition Powers: +0.50 D to +4.00 D
BIOFINITY TORIC MULTIFOCAL (comfilcon A) contact lens parameters:
- Diameter: 13.5 mm to 15.00 mm
- Base Curve: 8.0 mm to 9.5 mm mm
- Center Thickness: 0.05 mm to 0.60 mm (varies with power)
- Powers: -20.00 D to +20.00 D
- Cylinder: -0.25 D to -5.75 D
- Axis: 0° to 180° in 5° increments
- Addition Powers: +0.25 D to +4.00 D
The physical/optical properties of the lens are:
- Refractive Index: 1.40
- Light Transmittance: >97%
- Surface Character: Hydrophilic
- Water Content: 48%
- Specific Gravity: 1.04
- Oxygen Permeability:128 x 10-¹¹ (cm/sec)(ml O2/ml x mmHg) 35 ºC (Coulometric method)
Call our Customer Service Department at800-341-2020 for current av availability.
ACTIONS
When placed on the cornea in its hydrated state, the BIOFINITY (comfilcon A) A
soft (Hydrophilic) Contact Lens acts as a refracting medium to focus light
rays on the retina. The toric lens provides a more even surface over the
uneven astigmatic cornea and thus helps to focus light rays on the retina.
INDICATIONS FOR USE
Spherical and Aspherical
BIOFINITY and BIOFINITY XR SPHERE (comfilcon A) Soft (Hydrophilic)
Contact Lenses are indicated for the correction of ametropia (myopia and
hyperopia) in aphakic and non-aphakic persons with non-diseased eyes in powers
from -20.00 to +20.00 diopters. The lenses may be worn by persons who exhibit
astigmatism of 2.00 diopters or less that does not interfere with visual
acuity.
BIOFINITY ENERGYS™ ASPHERE (comfilcon A) Soft (Hydrophilic) Contact
Lenses are indicated for the correction of ametropia (myopia and hyperopia) in
aphakic and non-aphakic persons with non-diseased eyes in powers from -20.00
to +20.00 diopters. The lenses may be worn by persons who exhibit astigmatism
of 2.00 diopters or less that does not interfere with visual acuity.
Toric
BIOFINITY TORIC (comfilcon A) and BIOFINITY XR TORIC (comfilcon A) Soft
(Hydrophilic) Contact Lenses are indicated for the correction of ametropia
(myopia or hyperopia with astigmatism) in aphakic and nonaphakic persons with
non-diseased eyes in powers from -20.00 to +20.00 diopters and astigmatic
corrections from -0.25 to -5.75 diopters.
Multifocal
BIOFINITY MULTIFOCAL (comfilcon A) and BIOFINITY XR MULTIFOCAL (comfilcon A)
Soft (Hydrophilic) Contact Lenses are indicated for the correction of
refractive ametropia (myopia and hyperopia) and emmetropia with presbyopia in
aphakic and non-aphakic persons with non-diseased eyes in powers from -20.00
to +20.00
diopters and add powers from +0.50 to +4.00 diopters. The lenses may be worn
by persons who exhibit astigmatism of 2.00 diopters or less that does not
interfere with visual acuity.
Toric Multifocal
BIOFINITY TORIC MULTIFOCAL (comfilcon A) Soft (Hydrophilic) Contact
Lenses are indicated for the correction of ametropia (myopia or hyperopia with
astigmatism) with presbyopia in aphakic and nonaphakic persons with non-
diseased eyes in powers from -20.00 to +20.00 diopters with add powers from
+0.25 to +4.00 diopters and astigmatic corrections from -0.25 to -5.75
diopters.
The BIOFINITY (comfilcon A) Soft (Hydrophilic) Contact Lenses may be
prescribed for extended wear for up to 6 nights and 7 days of continuous wear.
It is recommended that the contact lens wearer be first evaluated on a Daily
Wear schedule prior to overnight wear. The lenses may be prescribed for either
one-week disposable wear or for frequent replacement with cleaning,
disinfection, and scheduled replacement.
When prescribed for frequent replacement, the lenses must be cleaned and
disinfected using a chemical disinfection system only.
CONTRAINDICATIONS (REASONS NOT TO USE)
Do not use the BIOFINITY lens when any of the following conditions exist:
- Acute and subacute inflammation or infection of the anterior chamber of the eye.
- Any eye disease, injury, or abnormality that affects the cornea, conjunctiva, or eyelids.
- Severe insufficiency of lacrimal secretion (dry eyes).
- Corneal hypoesthesia (reduced corneal sensitivity), if not aphakic.
- Any systemic disease that may affect the eye or be exaggerated by wearing contact lenses.
- Allergic reactions of ocular surfaces or adnexa that may be induced or exaggerated by wearing contact lenses or use of contact lens solutions.
- Allergy to any ingredient, such as mercury or thimerosal, in a solution, which is to be used to care for any BIOFINITY lens.
- Any active corneal infection (bacterial, fungal, or viral).
- If eyes become red or irritated.
- The patient is unable to follow the lens care regimen or unable to obtain assistance to do so.
WARNINGS:
PROBLEMS WITH CONTACT LENSES AND LENS CARE PRODUCTS COULD RESULT IN SERIOUS
INJURY TO THE EYE.
It is essential that the patient follows the directions of the Eye Care
Practitioner and all labeling instructions for proper use of contact lenses
and lens care products, including the lens case.
Patients should be advised of the following instructions for use and warnings
pertaining to contact lens wear:
i. Soaking and Storing the Lenses
Instruction for Use:
Use only fresh multi-purpose (contact lens disinfecting) solution each time
the patient soaks (stores) the lenses.
WARNING:
Do not reuse or “top off” old solutions left in the lens case since solution
reuse reduces effective lens disinfection and could lead to severe infection,
vision loss, or blindness.
“Topping-Off” is the addition of a fresh solution to solution that has been
sitting in the case.
ii. Rub and Rinse Time
Instruction for Use:
- Rub and rinse the lenses according to the recommended lens rubbing and rinsing times in the labeling of the multipurpose solution to adequately disinfect the lenses.
WARNING:
- Rub and rinse the lenses for the recommended amount of time to help prevent serious eye infections.
- Never use water, saline solution, or rewetting drops to disinfect the lenses. These solutions will not disinfect the lenses. Not using the recommended disinfectant can lead to severe infection, vision loss, or blindness.
iii. Lens Case Care
Instruction for Use:
-
Empty and clean contact lens cases with digital rubbing using fresh, sterile disinfecting solutions/contact lens cleaner. Never use water. Cleaning should be followed by
rinsing with fresh, sterile disinfecting solutions (never use water), and wiping the lens cases with fresh, clean tissue is recommended. Never air-dry or recap the lens case lids after use without any additional cleaning methods. If air drying, be sure that no residual solution remains in the case before allowing it to air dry. -
Replace the lens case according to the directions given by the Eye Care Practitioner or the labeling that came with the case.
-
Contact lens cases can be a source of bacterial growth.
WARNING:
Do not store the lenses or rinse the lens case with water or any non-sterile
solution. Only use fresh multi-purpose solutions to not contaminate the lenses
or lens case. Use of
non-sterile solutions can lead to severe infection, vision loss, or blindness.
iv. Water Activity
Instruction for Use:
- Do not expose the contact lenses to water while wearing them.
WARNING:
Water can harbor microorganisms that can lead to severe infection, vision loss, or blindness. If the lenses have been submersed in water when swimming in pools, lakes or
oceans, discard them, and replace them with a new pair. Ask the Eye Care Practitioner for recommendations about wearing the lenses during any activity involving water.
v. Discard Date on Multi-Purpose Solution Bottle
Instruction for Use:
- Discard any remaining solution after the recommended time period indicated on the bottle of multi-purpose solution used for disinfecting and soaking the contact lenses.
- The Discard date refers to the time to safely use contact lens care products after the bottle has been opened. It is not the same as the expiration date, which is the last date
that the product is still effective before it is opened.
WARNING:
Using the multi-purpose solution beyond the discard date could result in
contamination of the solution and can lead to severe infection, vision loss or
blindness.
- To avoid contamination, DO NOT touch the tip of the container on any surface. Replace cap after using.
- To avoid contaminating the solution, DO NOT transfer to other bottles or containers.
EYE PROBLEMS, INCLUDING CORNEAL ULCERS, CAN DEVELOP RAPIDLY AND LEAD TO LOSS OF VISION; IF THE
FOLLOWING IS EXPERIENCED:
- Eye Discomfort,
- Excessive Tearing,
- Vision Changes,
- Loss of Vision,
- Eye Redness,
- Or Other Eye Problems
PATIENTS SHOULD BE INSTRUCTED TO IMMEDIATELY REMOVE THE LENSES, AND PROMPTLY CONTACT THE EYE CARE PRACTITIONER.
- Daily wear lenses are not indicated for overnight wear, and patients should be instructed not to wear lenses while sleeping. Clinical studies have shown that the risk of serious adverse reactions is increased when these lenses are worn overnight.
- Studies have shown that contact lens wearers who are smokers have a higher incidence of adverse reactions than nonsmokers.
o Patients should be cautioned that proper use and care of contact lenses and lens care products, including lens cases, are essential for the safe use of these products. It is essential that patients follow their Eye Care Practitioner’s directions and all labeling instructions for the proper use of lenses and lens care products. Patients should fill their lens case with fresh solution every time they store their lenses, and never re-use the solution. Additionally, they should clean and rinse their lens case between uses as recommended by their Eye Care Practitioner. Eye problems, including corneal ulcers, can develop rapidly and lead to loss of vision.
o The result of a study
1 indicate the following:
a. The overall annual incidence of ulcerative keratitis in daily wear contact lens users is estimated to be about 4.1 per 10,000 persons and about 20.9 per 10,000 persons in
extended wear contact lens users.
b. The risk of ulcerative keratitis is 4 to 5 times greater for extended wear contact lens users than for daily wear users. When daily wear users who wear their lenses overnight and extended wear users who wear their lenses on a daily basis are excluded from the comparison, the risk among extended wear users are 10 to 15 times greater than among daily wear users. c. When daily users wear their lenses overnight (outside the approved indication), the risk of ulcerative keratitis is 9 times greater than among those who do not wear them overnight.
d. The overall risk of ulcerative keratitis may be reduced by carefully following directions for lens care, including cleaning the lens case.
e. The risk of ulcerative keratitis among contact lens users who smoke is estimated to be 3 to 8 times greater than among non-smokers.
f. If patients experience eye discomfort, excessive tearing, vision changes, redness of the eye or other problems, they should be instructed to immediately remove their lenses and promptly contact their Eye Care Practitioner. It is recommended that contact lens wears see their Eye Care Practitioner routinely as directed.
¹NewEnglandJournalofMedicine,September21,1989;321(12),pp.773-783
PRECAUTIONS
Special Precautions for Eye Care Practitioners
- Due to the small number of patients enrolled in clinical investigation of lenses, all refractive powers, design configurations, or lens parameters available in the lens material are not evaluated in significant numbers. Consequently, when selecting an appropriate lens design and parameters, the Eye Care Practitioner should consider all characteristics of the lens that can affect lens performance and ocular health, including oxygen permeability, wettability, central and peripheral thickness, and optic zone diameter.
- The potential impact of these factors on the patient’s ocular health should be carefully weighed against the patient’s need for refractive correction; therefore, the continuing ocular health of the patient and lens performance on the eye should be carefully monitored by the prescribing Eye Care Practitioner.
- Patients who wear contact lenses to correct presbyopia may not achieve the best corrected visual acuity for either far or near vision. Visual requirements vary with the individual and should be considered when selecting the most appropriate type of lens for each patient.
- Aphakic patients should not be fitted with any BIOFINITY contact lenses until the determination is made that the eye has healed completely.
- Fluorescein, a yellow dye, should not be used while the lenses are on the eyes. The lenses absorb the dye and become discolored. Whenever fluorescein is used in the eyes, the eyes should be flushed with a sterile saline solution that is recommended for in-eye use.
- Before leaving the Eye Care Practitioner’s office, the patient should be able to promptly remove the lenses or should have someone else available who can remove the lenses for him or her. Eye Care Practitioners should instruct the patient to remove the lenses immediately if the eye becomes red or irritated. Eye Care Practitioners should carefully instruct patients about the following care regimen and safety precautions:
- Do not use saliva or anything other than the recommended solutions for lubricating or wetting lenses.
- Never use solutions recommended for conventional hard contact lenses only.
- Always follow the directions in the package inserts for the use of contact lens solutions.
- Always use a chemical lens care system. Use of a heat care system can damage the comfilcon A contact lenses.
- Sterile unpreserved solutions, when used, should be discarded after the time specified in the labeling directions.
- If the lens sticks (stops moving) on the eye, follow the recommended directions on Care for a Sticking Lens. The lens should move freely on the eye for the continued health of the eye. If non-movement of the lens continues, the patient should be instructed to immediately consult his or her Eye Care Practitioner.
- Always wash and rinse your hands before handling lenses. Do not get cosmetics, lotions, soaps, creams, deodorant, or sprays in the eyes or on the lenses. It is best to put on lenses before putting on makeup. Water-based cosmetics are less likely to damage lenses than oil-based products.
- Do not touch the contact lenses with the finger or hands if the hands are not free of foreign materials, as lens damage may occur.
- Always handle lenses gently and avoid dropping them.
- Never use tweezers or other tools to remove lenses from the lens container unless specifically indicated for that use. Pour the lens into your hand.
- Do not touch the lens with fingernails.
- Carefully follow the handling, insertion, removal, cleaning, and wearing instructions in the Patient Instructions for BIOFINITY contact lenses and those prescribed by the Eye Care Practitioner.
- Never wear lenses beyond the period recommended by the Eye Care Practitioner.
- Always discard disposable lenses and lenses worn on a frequent replacement schedule after the recommended wearing schedule prescribed by the Eye Care Practitioner.
- Avoid all harmful or irritating vapors and fumes while wearing lenses.
- If aerosol products such as hairspray are used while wearing lenses, exercise caution and keep eyes closed until the spray has settled.
- Ask the Eye Care Practitioner about wearing the lenses during sporting activities.
- Inform the doctor (Health Care Practitioner) about being a contact lens wearer.
- Always contact the Eye Care Practitioner before using any medicine in the eyes.
- Always inform the employer of being a contact lens wearer. Some jobs may require use of eye protection equipment or may requirethat the patient not wear contact lenses.
- As with any contact lens, follow-up visits are necessary to assure the continuing health of the patient’s eyes. The patient should be instructed as to a recommended follow-up schedule.
ADVERSE REACTIONS
The patient should be informed that the following problems may occur:
-
Eyes stinging, burning, or itching (irritation), or other eye pain.
-
Comfort is less than when the lens was first placed on the eye.
-
Feeling that something is in the eye such as a foreign body or a scratched area.
-
Excessive watering (tearing) of the eyes.
-
Unusual eye secretions.
-
Redness of the eyes.
-
Reduced sharpness of vision (poor visual acuity).
-
Blurred vision, rainbows, or halos around objects.
-
Sensitivity to light (photophobia).
-
Dry eyes.
If the patient notices any of the above, he or she should be instructed to: -
Immediately remove the lenses.
-
If the discomfort or the problem stops, then look closely at the lens. If the lens is in some way damaged, do not put the lens back on the eye. Place the lens in the storage case and contact the Eye Care Practitioner. If the lens has dirt, an eyelash, or other foreign body on it, or the problem stops and the lens appears undamaged, the patient should thoroughly clean, rinse, and disinfect both lenses; then reinsert them. After reinsertion, if the problem continues the patient should immediately remove the lenses and consult the Eye Care Practitioner.
When any of the above problems occur, a serious condition such as infection,
corneal ulcer, neovascularization, or iritis may be present. The patient
should be instructed to keep the lens off the eye and seek immediate
professional identification of the problem and prompt treatment to avoid
serious eye damage.
FITTING
Conventional methods of fitting contact lenses apply to all BIOFINITY contact
lenses. For a detailed description of the fitting techniques, refer to the
BIOFINITY rofessional Fitting and Information Guide, copies of which are
available from:
CooperVision, Inc.
711 North Road
Scottsville, New York 14546
(800)-341-2020
www.coopervision.com
WEARING SCHEDULE
The wearing and replacement schedules should be determined by the Eye Care
Practitioner. Patients tend to over-wear the lenses initially. The Eye Care
Practitioner should emphasize the importance of adhering to the initial
maximum wearing schedule. Regular checkups, as determined by the Eye Care
Practitioner are also extremely important.
CooperVision recommends that all BIOFINITY lenses be discarded and replaced
with a new lens on a frequent replacement basis. The Eye Care Practitioner is
encouraged to determine an appropriate lens replacement schedule based upon
the response of the patient. DAILY WEAR: (less than 24 hours, while awake).
The maximum suggested wearing time is:
DAY | Hours | Day | Hours |
---|---|---|---|
1 | 6 | 4 | 12 |
2 | 8 | 5 | 14 |
3 | 10 | 6 | All waking hours |
The Eye Care Practitioner should determine the wearing and replacement
schedule, based upon the patient’s history and their ocular examination, as
well as the practitioner’s experience and clinical judgment.
EXTENDED WEAR : BIOFINITY contact lenses may be prescribed for daily wear
and extended wear for up to 6 nights/ 7 days of continuous day and night wear.
Not all patients can achieve the maximum wear time. It is recommended that the
contact lens wearer be evaluated on a daily wear schedule. If successful, then
a gradual introduction of
extended wear can be followed as determined by the prescribing Eye Care
Practitioner.
Once removed, it is recommended that the lens remain out of the eye for a
period of rest overnight or longer and discarded in accordance with the
prescribed wearing schedule. The Eye Care Practitioner should determine the
appropriate wearing time and provide specific instructions to the patient
regarding lens care, insertion, and removal.
General Lens Care: (For Planned Replacement)
Basic Instructions:
- Always use fresh, unexpired lens care solutions.
- Use the recommended chemical (not heat) system of lens care and carefully follow instructions on solution labeling. Different solutions cannot always be used together, and not all solutions are safe to use with all lenses. Do not alternate or mix lens care systems unless indicated on solution labeling.
- Lenses should be cleaned, rinsed, and disinfected each time they are removed. Cleaning and rinsing are necessary to remove mucus and film from the lens surface. Disinfecting is necessary to destroy harmful germs.
- Always remove, clean, rinse (as recommended by the Eye Care Practitioner), and disinfect lenses according to the schedule prescribed by the Eye Care Practitioner. The use of an enzyme cleaner is not recommended.
- The Eye Care Practitioner should recommend a care system that is appropriate for BIOFINITY contact lenses. Each lens care product contains specific directions for use and important safety information, which should be read and carefully followed.
- Note: Some solutions may have more than one function, which will be indicated on the label. Read the label on the solution bottle and follow directions.
- Clean one lens first (always the same lens first to avoid mix-ups), rinse the lens thoroughly with recommended saline or disinfection solution to remove the cleaning solution, mucus, and film from the lens surface, and put that lens into the correct chamber of the lens storage case. Then repeat the procedure for the second lens.
- After cleaning and rinsing, disinfect lenses using the system recommended by the manufacturer and/or Eye Care Practitioner.
- To store lenses, disinfect and leave them in the closed/unopened case until ready to wear. If lenses are not to be used immediately following disinfection, the patient should be instructed to consult the package insert or the Eye Care Practitioner for information on the storage of lenses.
- After removing the lenses from the lens case, empty and rinse the lens storage case with the solution as recommended by the lens case manufacturer; then allow the lens ase to air dry. When the lens case is used again, refill it with a storage solution. Replace the lens case at regular intervals as recommended by the lens case manufacturer or your Eye Care Practitioner.
- Eye Care Practitioners may recommend a lubrication/rewetting solution, which can be used to wet (lubricate) the lenses while they are being worn to make them more comfortable.
CHEMICAL LENS DISINFECTION (Including Hydrogen Peroxide):
- Clean the contact lenses with a recommended cleaning solution and thoroughly rinse them with a recommended rinsing solution.
- After cleaning and rinsing, to disinfect, carefully follow the instructions accompanying the disinfecting solution in the eye care regimen recommended by the lens manufacturer or the Eye Care Practitioner.
- When using hydrogen peroxide lens care systems, lenses must be neutralized before wearing. Follow the recommendations on the hydrogen peroxide system labeling.
- When using hydrogen peroxide lens care systems, the patient must use ONLY the lens case provided with the hydrogen peroxide care system. This case is specially designed to neutralize the solution. Failure to use the specialized case will result in severe stinging, burning, and injury to the eye. Follow the recommendations on the hydrogen peroxide system labeling exclusively. Following disinfection with a peroxide system, the lenses should be rinsed with sterile saline.
- Thoroughly rinse lenses with a fresh solution recommended for rinsing before inserting and wearing or following the instructions on the disinfection solution labeling.
- Do not heat the disinfection solution and lenses.
- Leave the lenses in the unopened storage case until ready to put on the eyes.
- CAUTION: Lenses that are chemically disinfected may absorb ingredients from the disinfecting solution which may be irritating to the eyes. A thorough rinse in a fresh sterile saline solution prior to placement in the eye should reduce the potential for irritation.
LENS CASE CLEANING AND MAINTENANCE
Contact lens cases can be a source of bacterial growth. Lens cases should be
emptied, cleaned, and rinsed with the solution recommended by the lens case
manufacturer, and allowed to air dry. Lens cases should be replaced at regular
intervals as recommended by the lens case manufacturer or the Eye Care
Practitioner.
CARE FOR A DRIED OUT (DEHYDRATED) LENS
If any BIOFINITY lens is exposed to air while off the eye, it may become
dry and brittle. In this event, simply dispose of the lens and replace with a
fresh one.
CARE FOR A STICKING (NONMOVING) LENS
If the lens sticks (stops moving or cannot be removed), the patient should be
instructed to apply 2 to 3 drops of the recommended lubricating or rewetting
solution directly to the eye and wait until the lens begins to move freely on
the eye before removing it. If non-movement of the lens continues for more
than 5 minutes, the patient should immediately consult the Eye Care
Practitioner.
EMERGENCIES
The patient should be informed that if chemicals of any kind (household
products, gardening solutions, laboratory chemicals, etc.) are splashed into
the eyes, the patient should: FLUSH THE EYES IMMEDIATELY WITH TAP WATER AND
IMMEDIATELY CONTACT THE EYE CARE PRACTITIONER OR VISIT A HOSPITAL EMERGENCY
ROOM WITHOUT DELAY.
HOW SUPPLIED
Each lens is supplied sterile in a blister pack containing buffered isotonic
saline solution. The blister is labeled with the base curve, diameter,
dioptric power, manufacturing lot number, and expiration date of the lens.
When applicable, the blister is also labeled with the added power, cylinder
power, and cylinder axis.
DO NOT USE IF THE BLISTER PACK IS BROKEN OR THE SEAL HAS BEEN DAMAGED
REPORTING OF ADVERSE REACTIONS
All serious adverse experiences and adverse reactions observed in patients
wearing any BIOFINITY contact lens or experienced with the lenses should be
reported to:
Attn: Product Services
711 North Road
Scottsville, New York 14546
800-341-2020
www.coopervision.com
Part Number: PI01099
Revision: D
Revision Date: 2022-03-18
References