CooperVision Biofinity Multifocal Monthly Contact Lenses User Guide
- June 4, 2024
- CooperVision
Table of Contents
CooperVision Biofinity Multifocal Monthly Contact Lenses
A simplified fitting philosophy
Our new fitting process is based on eye care professionals’ real-world experiences.
- Fitting lower ADD powers is now simpler than ever by using the same D lens design for both eyes
- Fitting higher ADD powers continues to be flexible, giving you more options for exceptional vision performance.
Initial visit
Step 1
Start with a new refraction and verifi cation of eye dominance fogging technique.
Step 2
Select the distance prescription based on spherical equivaequivalent corrected for the vertex distance. Choose D or N lens design based on needed ADD power
ADD | Dominant eye | Non Dominant eye |
---|---|---|
+1.00 | D | D |
+1.50 | D | D |
+2.00 | D | N |
+2.50 | D | N |
Step 3
Although lens will equilibrate quickly, allow patients to adapt to lenses for a minimum of 15 minutes before assessing vision. If binocular vision is unacceptable, perform a monocular over refraction, using hand-held trial lenses, to determine which eye needs improvement. To improve distance vision add +/-0.25D (up to +/-0.50D) to the eye that needs improvement. To improve near vision add +/-0.25D up to +/-0.50D to the eye that needs improvement.
Clinical Tips| Prescribe maximum plus power for distance vision| Test
patient’s near function vision with
---|---|---
| Do not over minus| their cell phone
| Choose the lower ADD power when possible; not necessary to overprescribe the
ADD power| Check visual acuity with room lights on
A unique multifocal lens for unique eyes
Balanced Progressive Technology
- Optimized for exceptional vision at all distances: near, intermediate, and far.
- Allows for personalized fitting for each wearer and each eye.
- Streamlined fitting process helps ensure success for presbyopic patients.
Follow up visit one week later
If patient requires further enhancement to distance or near visual acuity
Step 1
Evaluate binocular visual acuity.
Step 2
Check monocular visual acuity.
Step 3
Perform over refraction using hand-held trial lenses avoid using a phoropter.
FIRST OPTION
To improve either distance or near vision, modify distance vision by +/- 0.25D in the eye that needs improvement.
SECOND OPTION
To improve near vision add +0.50D to the ADD power of the eye that needs improvement.
Product specifications
For additional fitting tips, tutorials, and more information on Biofinity multifocal, visit www.coopervision.com/multifocal . The eye care professional retains the independent clinical judgment on how to fi t and prescribe lense