denz C0100072 Ocular Heater User Manual
- June 16, 2024
- denz
Table of Contents
denz C0100072 Ocular Heater
Product Information
Specifications
- Supported power input: 10 – 32 VDC
- Current consumption: 12 VDC: ~0.54 A, 24 VDC: ~0.30 A, Off: 0.00 A
- Heating power: ~7 W
Device Setup
- Attach the ocular heater to the eyepiece.
- Connect the cable provided to the camera and the ocular heater.
- Switch on the ocular heater. (15 minutes heat up time)
- Set the switch to ‘HI’ for very cold conditions climate.
- Set the switch to ‘OFF’ during long breaks to extend the camera’s battery life.
Green LED Indicator
- Illuminates: Heating up.
- Flashes: Operating temperature reached.
- Off: The switch is in the ‘OFF’ position or the internal safety circuit is activated.
Resetting the Internal Safety Circuit
- Set the switch to ‘OFF’.
- Check supply voltage (10 – 32 VDC).
- Restart the ocular heater.
Accessories
- 170-300 mm open-end Lemo spiral cable (C0100136)
- 200-500 mm open-end Lemo spiral cable (C0100086)
- 270-650 mm open-end Lemo spiral cable (C0100087)
Disclaimer
- Only use DENZ spiral cables.
- Never use a power supply higher than 40V.
- Mistreatment might damage both the heating element and circuit board.
- Any violation on the disclaimer mentioned above results in void of warranty.
FAQ
-
Q: Can I use a different brand of spiral cables?
A: No, it is recommended to only use DENZ spiral cables to ensure proper compatibility and performance. -
Q: What happens if I use a power supply higher than 40V?
A: Using a power supply higher than 40V can damage both the heating element and circuit board of the ocular heater. -
Q: How long does it take for the ocular heater to heat up?
A: The ocular heater takes approximately 15 minutes to heat up. -
Q: When should I set the switch to ‘HI’?
A: The ‘HI’ setting is recommended for very cold conditions climate. -
Q: Should I switch off the ocular heater during long breaks?
A: Yes, switching off the ocular heater during long breaks helps extend the camera’s battery life.
Ocular Heater
Scope of Delivery
- Ocular heater
- Cable
- Transport case
Specifications
-
Supported power input 10 – 32 VDC
-
Current consumption
12 VDC: ~0.54 A
24 VDC: ~0.30 A
Off: 0.00 A -
Heating power ~7 W
Device setup
- Attach the ocular heater to the eyepiece.
- Connect the cable provided to the camera and the ocular heater.
- Switch on the ocular heater. (15 minutes heat up time)
- Set the switch to ‘HI’ for very cold conditions (-18°C/-0.4°F).
- Set the switch to ‘LO’ for normal conditions and humid climates.
- Set the switch to ‘OFF’ during long breaks to extend the camera’s battery life.
Green LED indicator
- Illuminates Heating up.
- Flashes Operating temperature reached. Off
- The switch is in the ‘OFF’ position or the internal safety circuit is activated.
Resetting the internal safety circuit
- Set the switch to ‘OFF’.
- Check supply voltage (10 – 32 VDC).
- Restart the ocular heater.
Accessories
- 170-300 mm open-end Lemo spiral cable C0100136
- 200-500 mm open-end Lemo spiral cable C0100086
- 270-650 mm open-end Lemo spiral cable C0100087
Disclaimer
- Only use DENZ spiral cables
- Never use a power supply higher than 40V.
- Mistreatment might damage both the heating element and the circuit board.
- Any violation on the disclaimer mentioned above results in a void of warranty.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>