FADINI DARDO 430-230 Vac Electromechanical Gate Opener for Swing Gates Instruction Manual

June 3, 2024
FADINI

FADINI DARDO 430-230 Vac Electromechanical Gate Opener for Swing Gates

430-230 Vac Electromechanical Gate Opener for Swing
Gates

GENERAL WARNINGS FOR PEOPLE SAFETY

THANK YOU

Thank you for purchasing a Fadini product.
Please read these instructions carefully before using this appliance. The instructions contain important information which will help you get the best out of the appliance and ensure safe and proper installation, use and maintenance. Keep this manual in a convenient place so that you can always refer to it for the safe and proper use of the appliance.

INTRODUCTION

This operator is designed for a specific scope of applications as indicated in this manual, including safety, control and signaling accessories as minimum required with Fadini equipment. Any applications not explicitly included in this manual may cause operation problems or damages to properties and people. Meccanica Fadini snc is not liable for damages caused by the incorrect use of the equipment, or for applications not included in this manual or for malfunctioning resulting from the use of materials or accessories not recommended by the manufacturer. The manufacturer reserves the right to make changes to its products without prior notice. All that is not explicitly indicated in this manual is to be considered not allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability of the access, its general condition and the structure. Make sure that there is no risk of impact, crushing, shearing, conveying, cutting, entangling and lifting situations, which may prejudice people safety. Do not install near any source of heat and avoid contacts with ammable substances. Keep all the accessories able to turn on the operator (transmitters, proximity readers, key-switches, etc) out of the reach of the children. Transit through the access only with stationary operator. Do not allow children and/or people to stand in the proximity of a working operator. To ensure safety in the whole movement area of a gate it is advisable to install photocells, sensitive edges, magnetic loops and detectors. Use yellow-black strips or proper signals to identify dangerous spots. Before cleaning and maintenance operations, disconnect the appliance from the mains by switching off the master switch. If removing the actuator, do not cut the electric wires, but disconnect them from the terminal box by loosening the screws inside the junction box.

INSTALLATION

All installation operations must be performed by a qualified technician, in observance of the Machinery Directive 2006/42/CE and safety regulations EN 12453 – EN 12445. Verify the presence of a thermal-magnetic circuit breaker 0,03 A – 230 V – 50 Hz upstream the installation. Use appropriate objects to test the correct functionality of the safety accessories, such as photocells, sensitive edges, etc. Carry out a risk analysis by means of appropriate instruments measuring the crushing and impact force of the main opening and closing edge in compliance with EN 12445. Identify the appropriate solution necessary to eliminate and reduce such risks.

In case where the gate to automate is equipped with a pedestrian entrance, it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used. Apply safety nameplates with CE marking on the gate warning about the presence of an automated installation. The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier, including: layout and components of the installation, risk analysis, verification of safety accessories, verification of impact forces and reporting of residual risks.

INFORMATION FOR END-USERS

The end-user is required to read carefully and to receive information concerning only the operation of the installation so that he becomes himself responsible for the correct use of it. The end-user shall establish a written maintenance contract with the installer/maintenance technician (on -call). Any maintenance operation must be done by qualified technicians. Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE INSTALLATION

For optimum performance of system over time according to safety regulations, it is necessary to perform proper maintenance and monitoring of the entire installation: the automation, the electronic equipment and the cables connected to these. The entire installation must be carried out by qualified technical personnel, filling in the Maintenance Manual indicated in the Safety Regulation Book (to be requested or downloaded from the site www.fadini.net/supporto/downloads). Operator: maintenance inspection at least every 6 months, while for the electronic equipment and safety systems an inspection at least once every month is required. The manufacturer, Meccanica Fadini snc, is not responsible for non-observance of good installation practice and incorrect maintenance of the installation.

DISPOSAL OF MATERIALS

Dispose properly of the packaging materials such as cardboard, nylon, polystyrene etc. through specializing companies (after verification of the regulations in force at the place of installation in the field of waste disposal). Disposal of electrical and electronic materials: to remove and dispose through specializing companies, as per Directive 2012/19/UE. Disposal of substances hazardous for the environment is prohibited.

CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A – 37053 Cerea – VR – Italy) declares under own responsibility that: Dardo 430 complies with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic system”, along with original accessories and components as indicated by the manufacturing company. An automatic gate operator is, by law, a “machinery” and therefore the installer must fit the equipment with all of the applicable safety norms. The installer is also required to issue the installer’s Declaration of Conformity. The manufacturer is not liable for possible incorrect use of the product. The product complies with the following specific norms: analysis of the risks and subsequent action to cure them as per EN 12445 and EN 12453, Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 2014/30/UE. In order to certify the product, the manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT NORMS.
This product complies with the following norms:

  • CPD 89/106/CE
  • DM 2006/42/CE
  • BT 2006/45/CE
  • EMC 2004/108/CE
  • R&TTE 99/5/CE

GENERAL DESCRIPTION OF THE PRODUCT

Dardo 430 is a electromechanical operator for external mount on swinging gates in residential and block of ats applications. It comes in a kit format to operate two gate leafs. Command and safety accessories for a proper performance are included. It is a non reversible, 230 Vac power supplied motor-operator, complete with an incorporated encoder. Stop plates are fitted to the pressure cast aluminium body. The linear movements are by a brass shaft nut (threaded bush) and a screw shaft (rolled thread), all supported by a radial bearing and a lubricated bushing. In case of an electric power failure, Dardo 430 can be “released” by a custom-made, coded key and the gates moved by hand. Terminals are factory fitted to each operator and provide connections for the power supply and the encoder to the electronic controller Elpro 43 , to be installed stand alone, in a sheltered place.

NOTE : The Dardo operators are not handed units and therefore they come all alike both for the right and the left gates: following their respective connections to the Elpro 43 controller, they are identified as Dardo M1 (first gate to open and pedestriam mode) and Dardo M2 (gate delayed on opening) (Pic.3). Dardo does not come fitted with electronic limit switches as they are not necessary, limit stop positions are learned by the system in phase of programming as determined by the incorporated stop plates.

Pic. 1 displays all of the components that are delivered for the installation of each Dardo operator.
General Description Of The Product

PRODUCT APPLICATIONS

The table below shows the maximum dimensions of a gate leaf in relation to its maximum weight.

| cod. 430L – DARDO 430 – 230 Vac
---|---
Max. width per leaf L (m)| 2,0| 2,5| 2,8
Max. weight per leaf P (kg)| 350| 300| 250

NOTE : the gate structure should not be fully panelled without openings, avoid that in-filling is more than 50% of the gate surface.

EQUIPMENT REQUIRED FOR THE INSTALLATION

Equipment Required For The Installation

MAIN COMPONENTS AND ELECTRICAL WIRING DIAGRAM OF THE SYSTEM

Lay the cable pipes into the ground and make sure they are suitable to the soil nature and comply with the diagram below.

Indicative general layout. It is the installer’s care and responsibility to lay the cable pipes in the most suitable way for the electrical connections.

Main Components And Electrical Wiring Diagram Of The
System

LEGEND

  1. Dardo 430 motor operator: 4G x 1,5 mm² + 3 x 0,5 mm² cables
  2. Photocell transmitter (2 x 0,5 mm²)
  3. Ground stop in open gate position (not supplied with the equipment)
  4. Photocell receiver (4 x 0,5 mm²)
  5. Radio transmitter
  6. Ground stop in closed gate position (not supplied with the equipment)
  7.  Inspectable junction pit
  8. Keyswitch or push buttons panel (4 x 0,5 mm²)
  9.  Controller with plug-in radio receiver card
  10. Flasher with aerial (2 x 0,5 mm² + RG58)

Type of cables to be used (not included with the equipment):
Motor power supply, safety and command accessories: FROR CEI 20-20 CEI EN 50267-2-1 Aerial: RG58.

NOTE : with distances longer than 50 m increase cable section according to the actual absorption requirements of the various devices in compliance with the CEI EN 60204-1 norms.

INSTALLATION DISTANCES FOR OPENING INWARDS

Installation Distances For Opening Inwards

[A] in case D distance is required to be bigger, contact our technical department to get A and C changed accordingly
[B] make sure ground gate stops be fitted, mainly in open gate position (do not use the open incorporated stop plate)

INSTALLATION DISTANCES FOR OPENING OUTWARDS

Installation Distances For Opening Outwards

FIXING BRACKETS PREPARATION AND FASTENING
IMPORTANT : before fastening the mount brackets, consider that they are 55 mm vertically offset: the front fixing is 55 mm lower than the rear fixing to the gate post (Pic. 7).
First fixing is the front one to the gate by using a strengthing plate (according to C distance of Pic. 4 or Pic. 5, in the way as indicated in Pic. 6).

Fixing Brackets Preparation And Fastening

Fixing Brackets Preparation And Fastening

Get ready the rear fixing and fasten it to the gate post, in respect of the installation geometry (Pic. 4 or Pic. 5), and as indicated in Pic. 8.
Fixing Brackets Preparation And Fastening

FIXING TO GATE POST

Remove the rear cap protecting the electrical connections, located at the back of the operator. Make the opertor rear fork-like bracket to fit the gate post fixing plate on to the central hole (lateral holes are provided to adjust the rear fixing in case A and B distances might be wrong).

Fixing To Gate Post

FIXING TO GATE
Open the gate by hand and bring it close to the operator. Swing this one on to the front bracket so that the fastening pin fits into the bush of the front fixing plate, then tighten the locking screw, avoid overtightening.

Fixing To Gate Post

RELEASE FOR MANUAL OPERATIONS

In the release mode, the operator does not perform any operation on the gate, in spite of voltage continuing to be supplied. In this situation the gate can be opened and closed manually even if the operator is still mounted on to it. The same coded key allows for the opening of the sliding protection cover and the manual overriding (Pic. 11).
IMPORTANT: to set the operator back to work, carry out the described steps in the reverse order.

Release For Manual Operations

ADJUSTMENT OF THE MECHANICAL STOP PLATES(installations without ground gate stops)
Override the operator (see Pic. 11) so that it is disengaged from the gate, then open the gate by hand to the required position: loosen the screw that fastens the stop assembly and position the plates so that the front fixing touches the assembly in the required open (stop) gate position, then tighten the screw again (Pic. 12): the outer stop plate and its counterpart ie. the inner plate must adhere firmly to the toothed bars. Carry out the same steps with the gate in closed position (Pic. 13).
IMPORTANT: eventually set back the operator to re-engage the gate (steps in Pic. 11 in reverse order).

Adjustment Of The Mechanical Stop Plates

Adjustment Of The Mechanical Stop Plates

FITTING THE POWER SUPPLY CABLE

Fitting The Power Supply Cable

GATE OPENING INWARDS

IMPORTANT : the terminals of M1 (A1, B1, C1 and D1, E1, F1) and M2 (A2, B2, C2 and D2, E2, F2) motors in the controller correspond to:
– M1 = Dardo on 1st gate leaf to open and in pedestrian mode if selected.
– M2 = Dardo on the gate leaf delayed in opening.

IMPORTANT : on single gate installations where only one operator is mounted, it is sufficient to connect the motor to M1 and bridge E1 with E2, while A2, C2, B2, D2 and F2 terminals are not connected.

Gate Opening Inwards

GATE OPENING OUTWARDS

Gate Opening Outwards

ORDINARY MAINTENANCE

It is recommended that the operators and all the moving parts be inspected periodically (every 2-3 months or whenever necessary) and the inner rolled screw shaft lubricated with some grease from underneath the operator. it is also advised that the gate hinges and pivots be periodically lubricated as well.
Remove any possible obstacles and hindrances, the gates must be able to move freely in open and close directions.

Ordinary Maintenance

Ordinary Maintenance

TECHNICAL DATA

| Dardo 430 (230 Vac)
---|---
Motor power supply| 230 Vac – 50 Hz
Rated absorption| 1,5 A
Max. absorption| 1,7 A
Max. power| 300 W
Capacitor| 12,5 μF
Max. thrust power| 3.000 N
Opening time| 16 s ÷ 20 s [C]
Speed| 16 ÷ 20 mm/s [C]
Travel available from stop to stop| 320 mm
Weight| 8 kg
Frequency of use| semi-intensive 35%
Protection standards| IP 44
Working temperature| -20 °C +50 °C
Motor thermal protection| 160 °C

[C] opening/closing times depend on the installation distances, speed adjustment and gate inertia

|

2012/19/UE Directive Re. disposal of electric and electronic waste
DISPOSE PROPERLY OF MATERIALS
ARMFUL TO THE ENVIRONMENT

---|---

Via Mantova, 177/A – 37053 Cerea (VR) Italy
Ph. +39 0442 330422 Fax +39 0442 331054
info@fadini.netwww.fadini.net

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FADINI User Manuals

Related Manuals