FADINI Elpro 42 Control Programmer 4200L Instruction Manual
- June 1, 2024
- FADINI
Table of Contents
FADINI Elpro 42 Control Programmer 4200L
GENERAL WARNINGS FOR PEOPLE SAFETY
THANK YOU
- Thank you for purchasing a Fadini product.
- Please read these instructions carefully before using this appliance.
- The instructions contain important information that will help you get the best out of the appliance and ensure safe and proper installation, use and maintenance.
- Keep this manual in a convenient place so that you can always refer to it for the safe and proper use of the appliance.
INTRODUCTION
- This operator is designed for a specific scope of applications as indicated in this manual, including safety, control and signalling accessories as the minimum required with Fadini equipment.
- Any applications not explicitly included in this manual may cause operation problems or damage to properties and people.
- Meccanica Fadini S.r.l. is not liable for damages caused by the incorrect use of the equipment, or for applications not included in this manual or for malfunctioning resulting from the use of materials or accessories not recommended by the manufacturer.
- The manufacturer reserves the right to make changes to its products without prior notice.
- All that is not explicitly indicated in this manual is to be considered not allowed.
BEFORE INSTALLATION
- Before commencing operator installation assess the suitability of the access, its general condition and the structure.
- Make sure that there is no risk of impact, crushing, shearing, conveying, cutting, entangling and lifting situations, which may prejudice people’s safety.
- Do not install near any source of heat and avoid contact with flammable substances.
- Keep all the accessories able to turn on the operator (transmitters, proximity readers, key switches, etc) out of the reach of the children.
- Transit through the access only with the stationary operator.
- Do not allow children and/or people to stand in the proximity of a working operator.
- To ensure safety in the whole movement area of a gate it is advisable to install photocells, sensitive edges, magnetic loops and detectors.
- Use yellow-black strips or proper signals to identify dangerous spots.
- Before cleaning and maintenance operations, disconnect the appliance from the mains by switching off the master switch.
- If removing the actuator, do not cut the electric wires, but disconnect them from the terminal box by loosening the screws inside the junction box.
INSTALLATION
- All installation operations must be performed by a qualified technician, in observance of the Machinery Directive 2006/42/CE and safety regulations EN 12453 – EN 12445.
- Verify the presence of a thermal-magnetic circuit breaker 0,03 A – 230 V – 50 Hz upstream the installation.
- Use appropriate objects to test the correct functionality of the safety accessories, such as photocells, sensitive edges, etc.
- Carry out a risk analysis through appropriate instruments measuring the crushing and impact force of the main opening and closing edge in compliance with EN 12445.
- Identify the appropriate solution necessary to eliminate and reduce such risks.
- In case where the gate to automate is equipped with a pedestrian entrance, it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used.
- Apply safety nameplates with CE marking on the gate warning about the presence of an automated installation.
- The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier, including layout and components of the installation, risk analysis, verification of safety accessories, verification of impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
- The end-user is required to read carefully and to receive information concerning only the operation of the installation so that he becomes responsible for the correct use of it.
- The end-user shall establish a written maintenance contract with the installer/maintenance technician (on-call).
- Any maintenance operation must be done by qualified technicians.
- Keep these instructions carefully.
WARNINGS FOR THE CORRECT OPERATION OF THE INSTALLATION
- For optimum performance of the system over time according to safety regulations, it is necessary to perform proper maintenance and monitoring of the entire installation: the automation, the electronic equipment and the cables connected to these.
- The entire installation must be carried out by qualified technical personnel, filling in the Maintenance Manual indicated in the Safety Regulation Book (to be requested or downloaded from the site www.fadini.net/supporto/downloads).
- Operator: maintenance inspection at least every 6 months, while for the electronic equipment and safety systems an inspection at least once every month is required.
- The manufacturer, Meccanica Fadini S.r.l., is not responsible for the non-observance of good installation practices and incorrect maintenance of the installation.
DISPOSAL OF MATERIALS
Dispose properly of the packaging materials such as cardboard, nylon,
polystyrene etc. through specializing companies (after verification of the
regulations in force at the place of installation in the field of waste
disposal). Disposal of electrical and electronic materials: to be removed and
disposed of through specializing companies, as per Directive 2012/19/UE.
Disposal of substances hazardous for the environment is prohibited.
UE DECLARATION OF CONFORMITY (DoC)
- Manufacturer: Meccanica Fadini S.r.l.
- Address: Via Mantova, 177/A – 37053 Cerea – VR – Italy declare that the DoC is issued under our sole responsibility and belongs to the following product:
- Control unit model ELPRO 42 is in conformity with the relevant Union harmonisation legislation:
- Electromagnetic Compatibility Directive 2014/30/UE
- Low Voltage Directive 2014/35/UE
WIRING
ELECTRONIC CONTROLLER FOR DARDO 424 AND FOX 724 GATE OPERATOR ON DOUBLE SWINGING GATES
General Description
General description: the electronic controller ELPRO 42 has been designed to control the gate operator type DARDO 424 and FOX 724 at 24 V, mounted on single- or double-swinging gates. 230 V – 50 Hz single-phase power supplied. The manufacturer is not liable for incorrect use of the controller, and reserves also the right to change and update it to the latest standards of the art at any time.
IMPORTANT FOR THE INSTALLATION AND PROPER FUNCTIONING
- The controller is to be installed in a sheltered, dry place.
- Make sure that the power supply to the electronic controller be 230 V ±10%.
- In case of distances superior to 50 meters, increase the wire section.
- Fit the power supply to the controller with a 0,03 A, high-sensibility, magneto-thermal circuit breaker.
- For the power supply, electric motor and flasher use1,5 mm² section wires up to 50 m of distance.
- For the limit switches, photocells, command switches and accessories use 1 mm² section wires.
- If no stop button is used bridge terminals 3 and 6.
- N.W.: for applications such as light control, CCTV, etc. use solid-state relays to prevent interference with the microprocessor.
DIAGNOSTICS BY LEDs:
- L0 (Green ON) = Pair of photocells fitted inside, no obstacle detected
- L2 (Green ON) = Pair of photocells closing, no obstacle detected
- L4 (Red OFF) = Open, switches ON when a command pulse to open is given
- L5 (Red OFF) = Close, switches ON when a command pulse to close is given
- L6 (Green ON) = Stop, switches OFF when a command pulse to stop is given
- L7 (Red OFF) = Radio, switches ON when a transmitter button is pulsed and the radio contact is made on terminals 3 and 7
- L10 (Red OFF) = Switches ON in case of a short circuit with the 24 Vdc.
- It switches OFF when the short circuit fault is removed
- L15 (Green ON) = Safety edge open, switches OFF whenever the safety edge is engaged
- L16 (Green ON) = Safety edge close, switches OFF whenever the safety edge is engaged
- L18 (Red OFF) = Switches ON whenever a pedestrian command is given
- E1 (Red ON) = Encoder led
- E2 (Red ON) = Encoder led
TROUBLESHOOTING IN CASE OF FAILURE
- Make sure that the power supply to the controller be 230 V ±10%
- Check all the fuses
- Check the photocells contact, it must be normally closed
- Make sure that no voltage drop occurs between the control board and the electric motor
- Check all the NC contacts in the control board
NOTE WELL
All the possible connections to the control board terminals are also
illustrated in the respective instructions provided with the individual
accessories.
SELECT THROUGH DIP-SWITCH N.1 WHETHER TO USE DARDO 424 OR FOX 724. All possible connections to the programmer terminals are also illustrated in the instruction sheets of the individual accessories.
NOTE WELL: THE INSTALLATION OF NON-FADINI ORIGINAL ACCESSORIES MAY DAMAGE THE PC BOARD. MAKE SURE THAT FREE CONTACTS BE ALWAYS USED FOR THE NO-NC INPUTS. BRIDGE ALL THE NC CONTACTS NOT IN USE.
Dip-Switches
-
OFF Photocell. No stop in the opening
-
OFF Radio contact 3-7 stop and reverse in opening
-
OFF Semiautomatic functioning
-
OFF No pre-flashing before opening
-
OFF Radio contact 3-7 reverse on each pulsing
-
OFF
-
OFF No stroke reversing pulse in the opening.
-
OFF Flasher (contact 11-12) ON in dwell time.
-
OFF No reclosing after crossing the photocells
-
OFF No photocell DSA control before any operation
-
OFF
-
OFF
-
ON Photocell. Stop in opening
-
ON Radio contact 3-7 no stop and no reverse in opening
-
ON Automatic closing after dwell time
-
ON Fixed pre-flasing before gate moving
-
ON Radio contact 3-7 step by step: open-stop-close-stop
-
ON Enable braking speed adjustment
-
ON Stroke reversing pulse for 2 s is enabled in opening
-
ON Flasher (contact 11-12) OFF in dwell time.
-
ON Reclosing after crossing the photocells ( Dip 3= ON)
-
ON Photocell DSA control before any operation
-
ON Delete slowdown during opening
-
ON Delete slowdown during closing
INSTALLATION ON A SINGLE GATE
NOTE WELL: any new setting on the dip-switches controlling gate functions
is performed following an open or close pulse.
FORCE SETTING:
- The force is to be adjusted by the dedicated trimmer to a setting sufficient to move the gate.
- Before programming is started, it is recommended that the dedicated trimmer be set in proportion to gate weight and size.
- Such setting controls also the force developed on the slowdow phase and resistance on impact with an obstacle.
- An excessive amount of force against gate inertia implies that the installation may not be in full conformity with the EN 12445 and EN 12453 safety norms. Therefore, once the force to be exerted on the automated gate has been set, the installer is required to assess the forces involved according to the provisions of the EN 12445 and EN 12453 norms documented in the “Safety Norms” manual made available by the company on www.fadini.net.
FUNCTIONS OF ELPRO 42 CONTROL UNIT
AUTOMATIC / SEMIAUTOMATIC
- Automatic cycle: on pulsing an open command, the gate opens, stays open untill dwell time expires as set by the dwell trimmer, then closes automatically.
- On transiting through the outer pair of photocells, dwell time is reactivated.
- Semiautomatic cycle: on pulsing an open command, the gate opens and stops in the open position. A close pulse is needed for the gate to close.
GATE TRAVEL REVERSE ON CONTACT WITH AN OBSTACLE
- A function allowing for the travel direction to be reversed on contact with an obstacle.
- Sensitivity of the function is proportional to the force exerted by Dardo/Fox as set by the Force Trimmer.
- Opening phase: The travel direction is reversed allowing for the gate to be cleared of the obstacle.
- Gate is held and stopped waiting for a new command.
- Closing phase: The travel direction is reversed back to the gate stop in the open position.
- N.W. In case an obstacle is detected for 5 consecutive times during a complete cycle, open-dwell-close, the gate stays open waiting for a command.
RECLOSING ON ENGAGING THE PHOTOCELLS:
in opening and dwell phases ( DIP N° 3 = ON).
This function allows the gate auto close after 3 s from crossing the
photocells beam.
DSA: AUTOMATIC ASSESSMENT OF THE PHOTOCELLS STATUS
For DAS (Device for Safety Autotest) control to be enabled, connect only the
projectors of the photocells to these terminals and set Dip N° 10 = ON.
Before any gate operation, provided that this function is enabled, Elpro 42
performs a test on all the photocells connected to it to make sure they are
free from obstacles and properly working, otherwise, the gate is not allowed
to start moving.
OPENING BY EXTERNAL TIME CLOCK
Connections: parallel connect the NO contact of the time clock to terminals 4
open and 3 commons, and set the system to auto close by dip-switch n° 3 = ON.
How it works: set the clock to the required opening and closing times. On the
pre-set time the gate is opened and held open (the flasher goes off), and no
more commands (even by radio) are accepted until the closing time pre-set on
the clock expires. On expiring, and after the pre-set dwell time, automatic
close is performed.
Dip-switches and LED indication of the various functions
EXCLUDING GATE LEAF DELAY ON PROGRAMMING
(when it is required that both gate leafs be opened simultaneously and for
single gate applications where one motor only is involved).
Once all the electrical connections to the control unit have been properly
made (following the instructions included in the box) with all of the safety
and command accessories as required, programming can be carried out.
NOTE VERY WELL: all of the green LEDs must be ON, otherwise check the connections with any accessory, mainly the NC contacts of the safety devices installed (contacts of the inner and outer photocells, stop contact, safety edges, …).
PROGRAMMING THE UNIT TO OPERATE ON NO GATE LEAF DELAY MODE
ADJUSTING SPEED IN SLOWDOWN PHASE
- Default speed at the end of the slowdown phase is 25% of the maximum speed.
- It is possible to adjust the final speed of the slowdown phase as described in the steps below. Depending on the application requirements, an even softer stop of the gate at the end of the permitted stroke can be achieved or, on the contrary, a more vigorous one to facilitate latching in case an electric lock is fitted.
NOTE WELL: speed readjustments will be executed following any open/close/radio pulse. Readjust speed and then give an open/close/radio command to assess functioning.
PROGRAMMING THE UNIT TO OPERATE IN GATE LEAF DELAY MODE (when one gate leaf
overlaps the other in a closed position) Programming in this way is required
when gate leafs overlap each other, therefore they are to be started later on
opening and closing alternatively.
Once all the electrical connections to the control unit have been properly
made (following the instructions included in the box) with all of the safety
and command accessories as required, programming can be carried out.
NOTE VERY WELL: all of the green LEDs must be ON, otherwise check the connections with any accessory, mainly the NC contacts of the safety devices installed (contacts of the inner and outer photocells, stop contact, safety edges, …).
PROGRAMMING THE UNIT TO OPERATE ON GATE LEAF DELAY MODE
TECHNICAL SPECIFICATIONS
- Single-phase PCB power supply: 230 Vac ±10% 50 Hz
- Three-phase PCB power supply: –
- Max. power of motors: 200 W
- Courtesy light output: 24 Vdc – 50 mA
- Photocells/keyswitch/radio receiver output: 24 Vdc – 500 mA
- Pilot light output: 24 Vdc – 3 W
- DSA control output: 24 Vdc – 150 mA
- Flasher output: 24 Vdc – 15 W
- Motor run time: –
- Dwell time: 1 – 120 s
- Closing gate delay time: –
- Pedestrian opening time: –
- Box dimensions: 210x295x110 mm
- Protection standards: IP 64
- Working temperature: -20 °C +55 °C
- Power supply by battery: 12 V
Dimension