2FT LED Strip Fixture with Microwave Sensor
“`html
Specifications:
-
Product Name: SHARK LED Light Fixture
-
Available Sizes: 2FT, 4FT
-
Mounting Options: Surface Mounting, V-Hook Mounting,
Tamperproof Mounting -
Compliance: NSF Compliant
Product Usage Instructions:
Surface Mounting:
-
Secure Surface Mounting Brackets to the Mounting Surface using
appropriate screws. -
Unlatch the Lens and Tray Assembly from the Housing.
-
Feed supply wires through Conduit Plugs for electrical
splices. -
Use UL approved wire connectors for wiring.
-
Secure Lens and Tray Assembly to Housing by clamping latch
down. -
Push Housing into Surface Mounting Brackets ensuring it is
secure. -
Apply silicone or Teflon tape on all Conduit Plugs and seal any
gaps with caulk if needed.
V-Hook Mounting:
- Secure Surface Mounting Bracket to Housing.
- Loop V-Hook on Surface Mounting Bracket.
- Suspend Housing by connecting V-Hooks to chains suitable to
support the fixture’s weight.
Tamperproof Mounting:
-
Secure TPKSHARK-G2 Bracket to the Mounting Surface using
appropriate hardware. -
Ensure recommended distance center to center for bracket
placement.
FAQ:
Q: Can the SHARK LED Light Fixture be used for outdoor
applications?
A: Yes, the fixture is suitable for outdoor applications in wet
locations when ceiling or wall mounted.
Q: How should I prevent wiring damage during installation?
A: Do not expose wiring to edges of sharp objects and be careful
not to pinch the wires while securing components.
Q: What should I do if the outdoor surface is irregular?
A: Use caulk to seal any gaps around the Housing and ensure a
secure fit.
“`
INSTRUCTIONS
SHARK® FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
SHARK – 2FT
SHARK – 4FT
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE. RAB fixtures must be wired in accordance with the National
Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF
THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF
before installing or maintaining fixture. No user serviceable parts inside.
CAUTION: For proper weatherproof function all gaskets must be seated properly
and all screws inserted and tightened firmly. Apply weatherproof silicone
sealant around the edge of the ceiling mounting box and/or junction box. This
is especially important with an uneven ceiling surface. Silicone all plugs and
unused conduit entries. Suitable for wet locations. Min 75° supply conductors.
SURFACE MOUNTING
The fixture is suitable for outdoor applications in wet locations either
ceiling or wall mounted.
1. Use appropriate mounting screws (not supplied) to secure the Surface
Mounting Brackets (2 included) to Mounting Surface. Recommended Surface
Mounting Brackets distance center to center is 14-5/8″ (for SHARK2) and 37″
(for SHARK4). NOTE: Mount Surface Mounting Brackets (2) symmetrical about the
center of the fixture and aligned with each other.
2. Unlatch the Lens and Tray Assembly from Housing. Pre-installed Tether
Cables (2) will prevent Lens and Tray Assembly from falling down as shown in
Fig. 1.
3. Feed supply wires through one of the Conduit Plugs (3) to make electrical
splices. Cord-grips (2) are provided and can be used based on the application.
4. Use appropriate UL approved wire connectors as required by code to
complete wiring with supply wires. Be careful not to pinch the wires.
WARNING: To prevent wiring damage or abrasion, do not
expose wiring to edges of sharp objects.
5. Secure Lens and Tray Assembly to Housing by clamping Latch down. Be
careful not to pinch the wires. Check that the Gasket is fully seated.
6. Push Housing into Surface Mounting Brackets (2) as shown in Fig. 2. Ensure
that the Housing is secure to Surface
Mounting Brackets (2).
7. Use silicone or Teflon tape on all Conduit Plugs and on the threads of all
conduit entry points. If outdoor surface is irregular, use caulk to seal any
gaps around Housing.
Fig: 1
Latch
Fig: 2
Surface Mounting Bracket (2) Housing
Tether Cable Lens and Tray Assembly
Mounting Surface Surface Mounting Bracket Conduit Plug (3)
INSTRUCTIONS
SHARK® FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
NSF COMPLIANCE
To comply with NSF, apply silicone to the “X” drive on all plugs and any
unused bracket mounting holes as shown in Fig. 3. Use food grade silicone such
as Dow® Corning 732.
Fig: 3
Apply Silicone to Conduit Holes
V-HOOK MOUNTING
(V-Hook for Chain Mounting included)
1. Secure Surface Mounting Bracket (2) to Housing as shown in Fig. 4.
WARNING: Surface Mounting Brackets must be mounted to Housing.
2. Loop V-Hook (2 included) on Surface Mounting Bracket (2) as shown in Fig.
4.
3. To suspend Housing, connect each V-Hook to two (2) equal lengths of chain
(not supplied) and/or appropriate hardware (by others) suitable for mounting
surface. Chains must be suitable to support four (4) times the weight of the
fixture.
Fig: 4 Housing
V-Hook (2) Surface Mounting
Bracket
TAMPERPROOF MOUNTING
Tamper Proof Bracket Accessory (TPKSHARK-G2 ordered separately)
1. Use appropriate mounting hardware (not supplied) to secure the TPKSHARK-G2
Bracket (2) to Mounting Surface.
2. Recommended TPKSHARK-G2 Bracket distance center to center is 12 7/8″ for
SHARK 2ft and 36 13/16″ for SHARK 4ft.
3. Push Housing into TPKSHARK-G2 Bracket (2) as shown in Fig. 5 and fasten
onto Lens Groove.
4. Secure Housing onto TPKSHARK-G2 Bracket with provided Screws (2 per
Bracket) using star head T25 Drive as shown in Fig. 5.
JUNCTION BOX MOUNTING
Junction Box Bracket Accessory Fig. 6 (JBSHARK-G2 ordered separately)
1. Use appropriate mounting hardware (not supplied) to secure the JBSHARK-G2
Bracket to Mounting Surface or Junction Box (supplied by others). Check that
the Gasket is fully seated. Use Cord Grip provided to feed supply wires into
fixture.
2. Recommended JBSHARK-G2 Bracket distance center to center is 6 3/4″ for
SHARK 2ft and SHARK 4ft.
3. Use appropriate UL approved wire connectors as required by code to
complete wiring with supply wires. Be careful not to pinch the wires.
4. Push Housing into JBSHARK-G2 Bracket to secure fixture to Mounting Surface
as shown in Fig. 7.
Fig: 5 Lens Groove
Fig: 6
Fig: 7
Mounting Surface TPKSHARK-G2
Brackets (2) Screw
Housing
JBSHARK-G2 Bracket Gasket
Housing
Junction Box Mounting Surface
JBSHARK-G2 Housing
INSTRUCTIONS
SHARK® FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
ANGLE SURFACE MOUNTING
Angle Surface Mounting Brackets Fig. 8 (ANGSHARK-G2 ordered separately)
1. Use appropriate mounting hardware (not supplied) to secure the Angle
Bracket (ANGSHARK-G2) (2) to mounting surface as shown in Fig. 8.
2. Recommended Angle Bracket distance center to center is 12 7/8″ for SHARK
2ft and 36 13/16″ for SHARK 4ft.
3. Secure Surface Mounting Brackets (2) to Angle Bracket (2) with Screws
provided.
4. Snap Housing on Surface Mounting Brackets (2) as shown in Fig. 9.
FIELD ADJUSTMENT
Follow instructions below to change the Fixture Power (W) and/or Color
Temperature (CCT) from factory settings:
Factory Settings: SHARK2 25W / 4000K SHARK4 50W / 4000K
1. Locate the Field Adjustable Switches inside the Lens and Tray Assembly as
shown in Fig. 10.
2. Select Power (W) and Color Temperature (CCT) by sliding respective switch
to the desired value (Fig. 10).
Fig: 8 Screws
Angle Bracket (2)
Surface Mounting
Bracket Housing
Fig: 10 Power (W)
Color Temperature (CCT)
Fig: 9
INSTRUCTIONS
SHARK® FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
PIR MODELS
Screw Sensor Head onto the Bracket as shown in Fig. 11. See factory settings below (optional remote sold separately for
custom settings, CAT# MSR1).
Factory Settings:
· Brightness: 100% · Hold Time: 1 Minute · Daylight: Disabled
· Sensitivity: 100% · Stand-by dimming level: 20% · Stand-by time: 1 Minute
CONTROLLING LIGHTCLOUD BLUE DEVICE
1. Confirm your device is powered on.
2. Download the Lightcloud Blue app from the Apple® App store or Google
PlayTM store.
3. Launch the App and create an account or login.
4. Tap the “add device” icon in the app to start connecting devices.
5. Follow the remaining steps in the app. Create Areas and Groups and add
Scenes to organize and control your devices.
Bracket
Sensor Head
Fig. 11
MVS MODELS (Internal)
(optional remote sold separately for custom settings, CAT# MSR1).
Factory Settings:
· Brightness: 100%
· Sensitivity: 100%
· Hold Time: 20 Minutes · Stand-by dimming level: 20%
· Daylight: Disabled · Stand-by time: 1 Minute
LIGHTCLOUD® BLUE MVS & PIR MODELS
This is a 12V low voltage controller with an integrated occupancy sensor.
Screw the Sensor Head onto the Bracket as shown in Fig. 9.
Factory Settings: Uncommissioned State
· Motion Sensitivity: High · Brightness when triggered: 100% · Hold time: 1
Minute · Standby to dim: 20% · Stand-by time: 1 Minute
Factory Settings: Commissioned State
· Motion Sensitivity: High · Brightness when triggered: Last on status · Hold
time: 20 Minute · When vacant: Off
Sensors can work independently or to control a group. The sensor settings can
be adjusted at the Area level in the Lightcloud Blue App.
ENABLE DEVICE PAIRING MODE
If your Lightcloud Blue Low Voltage Controller+Sensor is already paired there
are various options to choose from to return the device to the default factory
settings.
Method 1: Delete from the App Open the app and access the device settings for
the paired device. Be sure that the device is online with a strong connection
and select `Delete’. The fixture will flash 3x, then reset to 100% brightness.
Method 2: Rapid Reset Tool The Rapid Reset process must be done by a
professional electrician qualified by RAB. Reach out to your RAB sales manager
to request a Rapid Reset Tool. The tool simply needs to be placed directly on
the side of the device for 2s or until the fixture flashes 3x, then resets to
100% brightness.
Fig:12
Bumps
INSTRUCTIONS
SHARK® FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz.
For 0-10V dimming follow the wiring directions as shown in Fig. 13.
1. Connect the black fixture lead to the LINE supply lead.
2. Connect the white fixture lead to the COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the
GROUND of the dimming fixture to the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the pink fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or
maintain while fixture is energized.
1. Lens should be washed in a solution of warm water and any mild, non-
abrasive household detergent, rinsed with clean water and wiped dry. WARNING:
Polycarbonate is affected by cleaning agents or other liquids containing
partial solvents such as low molecular weight aldehydes and ethers, ketones,
esters, aromatic hydrocarbons and perchlorinated hydrocarbons. In addition,
chemical attack ranging from partial to complete destruction of polycarbonate
occurs in contact with alkalines, alkali salts, amines and high zone
concentrations. Please go to rablighting.com for a detailed list of damaging
chemicals.
2. Do not open fixture to clean the LED. Do not touch the LED.
Fig:13
LINE COMMON ( + ) DIM V ( – ) DIM V
GROUND
BLACK
WHITE PURPLE PINK Vaux 12V YELLOW
GROUND
LIGHT FIXTURE
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to wiring
directions.
2. Is the fixture grounded properly?
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
INSTRUCTIONS
SHARK® FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
BATTERY BACKUP MODELS
WIRING
CAUTION: FOR BATTERY BACKUP FIXTURE. Voltage could be present in BATTERY. To
prevent high voltage from being present on output leads, inverter connector
must be open. Do not join BATTERY connector until installation is complete and
AC power is supplied to the emergency driver (Fig. 14).
NOTE: Make sure that the necessary branch circuit wiring is available. An
UNSWITCHED AC source of power is required. The emergency driver must be fed
from the same branch circuit as the LED driver.
CAUTION: Do not use any supply voltage other than 120-277V 50/60 HZ.
1. Connect UNSWITCHED HOT fixture lead to HOT AC supply line.
2. If using an UNSWITCHED circuit, connect UNSWITCHED and SWITCHED lines
together.
3. If using a SWITCHED circuit, connect SWITCHED HOT AC fixture lead to the
external SWITCHED.
4. Connect the NEUTRAL fixture lead to the NEUTRAL supply line.
5. For 0-10V Dimming, connect DIM (+) and DIM (-) to the supply DIM (+) and
DIM (-).
6. Connect GROUND lead from the fixture to the supply ground. Do not connect
GROUND to the output leads.
7. All unused lead must be capped and insulated.
8. After installation is complete, supply AC power to the fixture and connect
the BATTERY.
9. When power is on, the fixture should be on and the Charging Indicator
Light should illuminate to indicate the battery is charging.
10. Once the BATTERY has charged for at least one hour, a short duration test
may be performed by pressing the test button.
11. After the battery has charged for 24 hours, a long duration test can be
performed by shutting power to the fixture.
OPERATION
1. When AC power is applied, the charging indicator light is illuminated,
indicating that the BATTERY is being charged.
2. When power fails, the standby power automatically switches to emergency
power (internal battery), operating at reduced illumination. Not all LED
boards will illuminate with standby power. The emergency driver supplies 25W
of power in standby power for a minimum of 90 minutes.
3. When AC power is restored, the emergency driver automatically returns to
charging mode.
MAINTENANCE
Although no routine maintenance is required to keep the emergency driver
functional, it should be checked periodically to ensure that it is working.
The following schedule is recommended: 1. Visually inspect the charging
indicator light monthly. It
should be illuminated. 2. Test the emergency operation of the fixture at
30-day
intervals for a minimum of 30 seconds. 3. Conduct a 90-minute discharge test
once a year. Fixture
would operate at reduced illumination for a minimum of 90 minutes.
TROUBLESHOOTING
1. Is the fixture grounded properly? 2. If the charging indicator light does
not illuminate after
pressing the test button (Fig. 15), check if battery is connected properly.
Fig: 15
LIGHT FIXTURE
Purple/DIM+ Pink (or Gray)/DIM
Black/Switched Line Black/Unswitched Line
White/Neutral Green/Ground
© 2024 RAB LIGHTING Inc.
SHARK FA 2FT 4FT IN 0424 P-100499
Easy Answers
rablighting.com Visit our website for product info
INSIDE FIXTURE
BACKUP DRIVER
BATTERY CONNECTOR: CONNECT ONLY AFTER AC SUPPLY POWER IS CONNECTED
BATTERY
Fig: 14
Battery Test Button
Note: These instructions do not cover all details or variations in equipment
nor do they provide for every possible situation during installation,
operation or maintenance.
Tech Help Line Call our experts: 888 722-1000
e-mail Answered promptly – sales@rablighting.com
Free Lighting Layouts Answered online or by request
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>