MEAN WELL RS-15 Series LED Displays Power Supply Installation Guide
- September 26, 2024
- MEAN WELL
Table of Contents
MEAN WELL RS-15 Series LED Displays Power Supply Installation Guide
Features
- Universal AC input/ Full range
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- No load power consumption<0.5W
- All using 105°C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70°C
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- 3 years warranty
Symbols
IS13252
AS/NZS62368-1
UL62368-1
GB4943.1
BS EN/EN62368-1
R33100 RoHS
TPTC004
IEC62368-1
SPECIFICATION
MODEL| RS-15-3.3| RS-15-5| RS-15-12| RS-15-15|
RS-15-24| RS-15-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 3A| 3A| 1.3A| 1A| 0.625A| 0.313A
CURRENT RANGE| 0 ~ 3A| 0 ~ 3A| 0 ~ 1.3A| 0 ~ 1A| 0 ~ 0.625A| 0 ~
0.313A
RATED POWER| 9.9W| 15W| 15.6W| 15W| 15W| 15.024W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 80mVp-p|
120mVp-p| 120mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 2.9 ~ 3.6V| 4.75 ~ 5.5V| 10.8 ~ 13.2V| 13.5 ~
16.5V| 22 ~ 27.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION **Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
LOAD REGULATION ****Note.5| ±2.0%| ±1.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 1000ms, 30ms/115VAC
at full load
HOLD UP TIME (Typ.)| 70ms/230VAC 12ms/115VAC at full
load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 72%| 77%| 81%| 81%| 82%| 82%
AC CURRENT (Typ.)| 0.35A/115VAC 0.25A/230VAC
INRUSH CURRENT (Typ.)| COLD START 65A / 230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~
20.25V| 28.4 ~ 32.4V| 55.2 ~ 64.8V
Protection type : Shut off o/p voltage, clamping by zener diode
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically
after temperature goes down
ENVIRONMENT| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating
Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC (Note 6)| SAFETY STANDARDS|
UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1, EAC TP TC 004, CCC GB4943.1,
BSMI CNS15598-1, BIS IS13252(Part1):2010/IEC 60950-1: 2005 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC /
25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS15936 Class B
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8,11, BS
EN/EN55035, BS EN/EN61000-6-1, light industry level, EAC TP TC 020
OTHERS| MTBF| 4914.9K hrs min. Telcordia SR-332 (Bellcore) ;
1608.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 62.55128mm (LWH)
PACKING| 0.13Kg; 108pcs/15Kg/0.8CUFT
NOTE**|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Line regulation is measured from low line to high line at rated load.
- Load regulation is measured from 0% to 100% rated load.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Terminal Pin No. Assignment
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4 | DC OUTPUT -V |
2 | AC/N | 5 | DC OUTPUT +V |
3 | FG |
Block Diagram
Derating Curve
AMBIENT TEMPERATURE ( )
Output Derating VS Input Voltage
INPUT VOLTAGE (VAC) 60Hz
https://www.meanwell.com/serviceGTIN.aspx