AUTEL MaxiVCI V200S VCI Wireless Diagnostic Interface User Manual
- June 5, 2024
- AUTEL
Table of Contents
AUTEL MaxiVCI V200S VCI Wireless Diagnostic Interface
Trademarks
Autel®, MaxiCOM®, MaxiDAS®, MaxiScan®, MaxiTPMS®, MaxiRecorder®, and MaxiCheck® are trademarks of Autel Intelligent Technology Corp., Ltd., registered in China, the United States and other countries. All other marks are trademarks or registered trademarks of their respective holders.
Copyright Information
No part of this manual may be reproduced, stored in a retrieval system or
transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise without the prior written permission of
Autel.
Disclaimer of Warranties and Limitation of Liabilities
All information, specifications and illustrations in this manual are based on
the latest information available at the time of printing. Autel reserves the
right to make changes at any time without notice. While information of this
manual has been carefully checked for accuracy, no guarantee is given for the
completeness and correctness of the contents, including but not limited to the
product specifications, functions, and illustrations. Autel will not be liable
for any direct damages or for any special, incidental, or indirect damages or
for any economic consequential damages (including the loss of
profits).IMPORTANT: Before operating or maintaining this unit, please read
this manual carefully, paying extra attention to the safety warnings and
precautions.
Safety Information
For your own safety and the safety of others, and to prevent damage to the
device and vehicles upon which it is used, it is important that the safety
instructions presented throughout this manual be read and understood by all
persons operating or coming into contact with the device.There are various
procedures, techniques, tools, and parts for servicing vehicles, as well as in
the skill of the person doing the work. Because of the vast number of test
applications and variations in the products that can be tested with this
equipment, we cannot possibly anticipate or provide advice or safety messages
to cover every circumstance. It is the automotive technician’s responsibility
to be knowledgeable of the system being tested. It is crucial to use proper
service methods and test procedures. It is essential to perform tests in an
appropriate and acceptable manner that does not endanger your safety, the
safety of others in the work area, the device being used, or the vehicle being
tested.
Before using the device, always refer to and follow the safety messages and
applicable test procedures provided by the manufacturer of the vehicle or
equipment being tested. Use the device only as described in this manual. Read,
understand, and follow all safety messages and instructions in this manual.
Safety Messages
Safety messages are provided to help prevent personal injury and equipment
damage. All safety messages are introduced by a signal word indicating the
hazard level.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury to the operator or to bystanders.
WARNING: Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury to the operator or to bystanders.
Safety Instructions
The safety messages herein cover situations Autel is aware of. Autel cannot
know, evaluate or advise you as to all of the possible hazards. You must be
certain that any condition or service procedure encountered does not
jeopardize your personal safety.
DANGER:
When an engine is operating, keep the service area WELL VENTILATED or attach a
building exhaust removal system to the engine exhaust system. Engines produce
carbon monoxide, an odorless, poisonous gas that causes slower reaction time
and can lead to serious personal injury or loss of life.Do Not Turn the Volume
Up Too Loud When Using Headphones
Listening at high volumes that over-stimulate the ear for long periods of time
may result in loss of hearing.
SAFETY WARNINGS:
- Always perform automotive testing in a safe environment.
- Wear safety eye protection that meets ANSI standards.
- Keep clothing, hair, hands, tools, test equipment, etc. away from all moving or hot engine parts.
- Operate the vehicle in a well-ventilated work area, for exhaust gases are poisonous.
- Put the transmission in PARK (for automatic transmission) or NEUTRAL (for manual transmission) and make sure the parking brake is engaged.
- Put blocks in front of the drive wheels and never leave the vehicle unattended while testing.
- Be extra cautious when working around the ignition coil, distributor cap, ignition wires and spark plugs. These components create hazardous voltages when the engine is running.
- Keep a fire extinguisher suitable for gasoline, chemical, and electrical fires nearby.
- Do not connect or disconnect any test equipment while the ignition is on or the engine is running.
- Keep the test equipment dry, clean, free from oil, water or grease. Use a mild detergent on a clean cloth to clean the outside of the equipment as necessary.
- Do not drive the vehicle and operate the test equipment at the same time. Any distraction may cause an accident.
- Refer to the service manual for the vehicle being serviced and adhere to all diagnostic procedures and precautions. Failure to do so may result in personal injury or damage to the test equipment.
- To avoid damaging the test equipment or generating false data, make sure the vehicle battery is fully charged and the connection to the vehicle DLC is clean and secure.
- Do not place the test equipment on the distributor of the vehicle. Strong electromagnetic interference can damage the equipment.
Chapter 1 Using This Manual
This manual contains device usage instructions. Some illustrations shown in this manual may contain modules and optional equipment that are not included in your system. Contact your sales representative for the availability of other modules and optional tools or accessories.
Conventions
The following conventions are used.
Bold Text
Bold text is used to highlight selectable items such as buttons and menu
options.
Example:Tap OK.
Notes
A NOTE provides helpful information such as additional explanations, tips,
and comments.
Important
IMPORTANT indicates a situation which, if not avoided, may result in damage
to the test equipment or vehicle.
Hyperlink
Hyperlinks, or links, that take you to other related articles, procedures,
and illustrations are available in electronic documents. Blue colored text
indicates a selectable hyperlink.
Procedure
An arrow icon indicates a procedure. Example:
To use the camera:
- Tap the Camera button. The camera screen opens.
- Focus the image to be captured in the view finder.
- Tap the blue circle. The view finder now shows the captured picture and auto-saves the taken photo.
VCI – Wireless Diagnostic Interface
The wireless diagnostic interface MaxiVCI V200S is a small vehicle communication interface (VCI) used to connect to a vehicle’s diagnostic connector (DLC) and connect with the Display Tablet, as well as standalone PC, as a vehicle communication interface (VCI) for vehicle data transmission.
Functional Description
-
Lighting Push Button – presses to turn on the white LED in the vehicle data connector socket
-
Power LED – indicates power and system status
Yellow: illuminates solid yellow when powered on and performing self-check
Green: illuminates solid green when ready for use
Red: flashes red when the firmware is updating -
Vehicle/Connection LED – indicates vehicle and connection status Green: illuminates green when connected via USB cable; flashes green when communicating via USB cable
Blue: illuminates blue when connected via Bluetooth; flashes blue when communicating via Bluetooth -
Vehicle Data Connector (16-pin) – connects the MaxiVCI V200 to the vehicle’s 16-pin DLC directly
-
USB Port – provides the easiest connection between the device and the display tablet via a USB cable
Communication
The Wireless Diagnostic Interface supports both the wireless BT and the USB
communication. It can transmit vehicle data to the Display Tablet with or
without a physical connection. The working range of the transmitter through BT
communication is about 32.8 feet (about 10 m). A signal lost due to moving out
of range automatically restores itself when the Display Tablet is brought
closer to the VCI unit.
Technical Specifications
Item | Description |
---|---|
Communications | l BR/EDR |
l USB 2.0
Wireless Frequency| 2.4 GHz
Input Voltage Range| 6 V-36V DC
Supply Current| 1A @ DC5V
Operating Temperature| -10°C to 60°C (14°F to 140°F)
---|---
Storage Temperature| -40°C to 80°C (-40°F to 176°F)
Dimensions ( L x W x H )| 89.89 mm (3.53”) x 46.78 mm (1.84”) x
21 mm
(0.82”)
Weight| 70.7g (0.156 lb.)
Built-in Battery| 3.7V Lithium Battery
Light| White LED
Power Sources
The Wireless Diagnostic Interface operates on 12-volt vehicle power, which
it receives through the vehicle data connection port. The unit powers on
whenever it is connected to an OBD II/EOBD compliant data link connector
(DLC).
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: This device may not cause harmful interference,
and this device must accept any interference received, including interference
that may cause undesired operation. Warning: Changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance 20cm between the radiator & your body.
WARNING:
- Applying a voltage to the ground input is likely to cause permanent damage to the oscilloscope, the attached computer, and other equipment.
- To prevent measurement errors caused by poor grounding, always use the high-quality USB cable supplied with the oscilloscope.
External connections
DANGER:
To prevent injury or death, use only the power cord and adaptor supplied with
the product.
Environment
DANGER:
To prevent injury or death, do not use in wet or damp conditions, or around
explosive gas or vapor.
WARNING:
To prevent damage, always use and store your oscilloscope in appropriate
environments. For detailed information on temperature and humidity
specifications for both the storage and usage of the oscilloscope, see 15.1
Safety Information on page 97.
Product Maintenance
The product contains no user-serviceable parts. Repair, servicing and
calibration require specialized test equipment and must only be performed by
Autel Tech Support or an approved service provider.
DANGER:
To prevent injury or death, do not use the product if it appears to be
damaged in any way, and stop use immediately if you are concerned by any
abnormal operations.
WARNING:
- Do not tamper with or disassemble the oscilloscope, connectors or accessories. Internal damage will affect performance.
- Do not block any of the instrument’s air vents as overheating will cause damage to the oscilloscope.
- When cleaning the oscilloscope, use a wet soft cloth with a mild detergent in water. Do not allow water to enter the oscilloscope casing, as this will cause damage to the electronics inside.
Chapter 19 Warranty
12-Month Limited Warranty
Autel Intelligent Technology Corp., Ltd. (the Company) warrants to the
original retail purchaser of this MaxiCOM Diagnostic Device, that should this
product or any part thereof during normal consumer usage and conditions, be
proven defective in material or workmanship that results in product failure
within twelve (12) months period from the date of delivery, such defect(s)
will be repaired, or replaced (with new or rebuilt parts) with Proof of
Purchase, at the Company’s option, without charge for parts or labor directly
related to the defect(s).The Company shall not be liable for any incidental or
consequential damages arising from the use, misuse, or mounting of the device.
Some states do not allow limitation on how long an implied warranty lasts, so
the above limitations may not apply to you. This warranty does not apply to:
- Products subjected to abnormal use or conditions, accident, mishandling, neglect, unauthorized alteration, misuse, improper installation or repair or improper storage;
- Products whose mechanical serial number or electronic serial number has been removed, altered or defaced;
- Damage from exposure to excessive temperatures or extreme environmental conditions;
- Damage resulting from connection to, or use of any accessory or other product not approved or authorized by the Company;
- Defects in appearance, cosmetic, decorative or structural items such as framing and non-operative parts.
- Products damaged from external causes such as fire, dirt, sand, battery leakage, blown fuse, theft or improper usage of any electrical source.
IMPORTANT :
All contents of the product may be deleted during the process of repair. You
should create a back-up copy of any contents of your product before delivering
the product for warranty service.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>