MEAN WELL GSM18E Series 18W AC-DC Reliable Green Medical Adaptor Owner’s Manual
- September 26, 2024
- MEAN WELL
Table of Contents
- GSM18E Series 18W AC-DC Reliable Green Medical Adaptor
- Product Specifications
- Product Usage Instructions
- 1. Safety Precautions
- 2. Connection
- 3. Powering On
- 4. Output Adjustment
- 5. Storage and Maintenance
- Q: What should I do if the adapter gets overheated during
- Q: Can I use this adapter with devices that have different
GSM18E Series 18W AC-DC Reliable Green Medical Adaptor
“`html
Product Specifications
Model | DC Voltage | Rated Current | Rated Power (max.) |
---|---|---|---|
GSM18E05 | 5V | 3A | 15W |
GSM18E07 | 7.5V | 2A | 15W |
Product Usage Instructions
1. Safety Precautions
Before using the adapter, carefully read and understand the
safety instructions provided in the user manual.
2. Connection
Ensure the power source is compatible with the input voltage
range specified for the adapter. Connect the DC plug securely to
the device requiring power.
3. Powering On
Once connected, plug the adapter into a suitable power outlet.
The adapter should power on, indicated by a light or sound
depending on the model.
4. Output Adjustment
If your device has specific voltage requirements, ensure the
adapter’s output matches these requirements to prevent damage.
5. Storage and Maintenance
When not in use, store the adapter in a cool, dry place away
from moisture and direct sunlight. Regularly check for any damage
to the adapter or cables.
Frequently Asked Questions (FAQ)
Q: What should I do if the adapter gets overheated during
use?
A: If you notice the adapter getting excessively hot,
immediately unplug it from the power source and allow it to cool
down before further use. Contact customer support if the issue
persists.
Q: Can I use this adapter with devices that have different
voltage requirements?
A: It is recommended to use the adapter only with devices that
fall within the specified voltage range to avoid potential damage
to your devices.
“`
18W AC-DC Reliable Green Medical Adaptor
GSM18E series
User’s Manual
Video
IEC/EN60601-1 IEC/EN 60601-1-11
EN60601-1/-1-11
IEC60601-1/-1-11 TPTC004
++
×
https://www.meanwell.com/serviceGTIN.aspx
https://www.meanwell.com/upload/pdf/DC_plug.pdf
×
{ × ×
Downloaded from Arrow.com.
File Name:GSM18E-SPEC 2024-04-26
18W AC-DC Reliable Green Medical Adaptor
GSM18E series
SPECIFICATION
ORDER NO.
GSM18E05-P1J GSM18E07-P1J GSM18E09-P1J GSM18E12-P1J GSM18E15-P1J GSM18E18-P1J GSM18E24-P1J GSM18E48-P1J
SAFETY MODEL NO.
GSM18E05 GSM18E07 GSM18E09 GSM18E12 GSM18E15 GSM18E18 GSM18E24 GSM18E48
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
3A
2A
2A
1.5A
1.2A
1A
0.75A
0.375A
CURRENT RANGE
0 ~ 3A
0 ~ 2A
0 ~ 2A
0 ~ 1.5A
0 ~ 1.2A
0 ~ 1A
0 ~ 0.75A
0 ~ 0.375A
RATED POWER (max.)
15W
15W
18W
18W
18W
18W
18W
18W
OUTPUT
RIPPLE & NOISE (max.) Note.3 60mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
LINE REGULATION Note.5 ±1.0%
LOAD REGULATION
±5.0%
80mVp-p ±5.0% ±1.0% ±5.0%
80mVp-p ±5.0% ±1.0% ±5.0%
120mVp-p ±3.0% ±1.0% ±3.0%
120mVp-p ±3.0% ±1.0% ±3.0%
150mVp-p ±3.0% ±1.0% ±3.0%
180mVp-p ±2.0% ±1.0% ±2.0%
240mVp-p ±2.0% ±1.0% ±2.0%
SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
16ms / 230VAC 16ms / 115VAC at full load
VOLTAGE RANGE
Note.7 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
80%
83%
84%
85%
85.5%
86%
87%
88%
AC CURRENT (Typ.)
0.5A / 115VAC 0.25A / 230VAC
INRUSH CURRENT (Typ.)
55A / 230VAC
30A / 115VAC
LEAKAGE CURRENT(max.) Touch current < 50A/264VAC
OVERLOAD PROTECTION
OVER VOLTAGE
WORKING TEMP.
105 ~ 170% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.25 ~ 7.5V 7.88 ~ 10.13V 9.45 ~ 12.6V 12.6 ~ 17.2V 15.75 ~ 20.25V 18.9 ~ 24.3V Protection type : Shut down o/p voltage, re-power on to recover -25 ~ +60 (Refer to “Derating Curve”)
25.2 ~ 32.4V
50.4 ~ 64.8V
WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20% ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing ±0.03% / (0~40)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
ISOLATION LEVEL WITHSTAND VOLTAGE ISOLATION RESISTANCE
IEC 60601-1:2005+A1+A2; IEC 60601-1-11:2015+A1, TUV BS EN/ EN
60601-1:2006+A1+A12+A2; BS EN/ EN 60601-1-11:2015+A1, EAC TP TC 004 approved
Primary-Secondary: 2xMOPP
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
Parameter
Standard
Test Level / Note
Conducted emission
EN55011 (CISPR11)
Class B
SAFETY &
EMC (Note. 8)
EMC EMISSION
Radiated emission
Harmonic current Voltage flicker
EN55011 (CISPR11)
EN61000-3-2 EN61000-3-3
Class B
Class A —–
EN60601-1-2, EN61204-3
Parameter
Standard
Test Level / Note
ESD
EN61000-4-2
Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility
EN61000-4-3
Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz )
EMC IMMUNITY
EFT bursts Surge susceptibility
EN61000-4-4 EN61000-4-5
Level 3, 2KV Level 3, 1KV/Line-Line
Conducted susceptibility
EN61000-4-6
Level 3, 10V
Magnetic field immunity
EN61000-4-8
Level 4, 30A/m
Voltage dip, interruption
EN61000-4-11
100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods
MTBF
3888.9K hrs min. Telcordia SR-332 (Bellcore) ; 794.6K hrs min. MIL-HDBK-217F (25)
OTHERS DIMENSION
795433mm (LWH)
PACKING
200g ; 60pcs / 13Kg / CARTON
PLUG CONNECTOR CABLE
See page 4~5 ; Other type available by customer requested See page 4~5 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1F & 47F capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
NOTE
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:GSM18E-SPEC 2024-04-26
Downloaded from Arrow.com.
LOAD (%)
54 38
LOAD (%)
18W AC-DC Reliable Green Medical Adaptor
GSM18E series
Derating Curve
Static Characteristics
100 80 60 40 20
-25
0
10 20 30 40 50 60
70 (HORIZONTAL)
AMBIENT TEMPERATURE ()
100 90 80 70 60 50 40
80 95 100 110 120 140 160 180 200 220 240 264
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Unit:mm
UL1185 16AWG 1200±50mm for 5~9V UL1185 18AWG 1800±50mm for 12~48V
POWER LED
NAME PLATE
79
33
70±10mm
Downloaded from Arrow.com.
File Name:GSM18E-SPEC 2024-04-26
18W AC-DC Reliable Green Medical Adaptor
GSM18E series
DC output plug Standard plug: P1J
P1J 5.5
2.1
11±0.5mm
Pin Assignment
C”+”
Outside
Inside
DC plug changeable through: (1) Customization of the standard part with an
optional DC plug according to the table (MOQ applicable) (2) Quick adapter
accessory (sold separately without MOQ) Please refer to below table and online
selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory:
Optional DC plug: (Available in customized cable or quick adapter)
Tuning Fork Style
Type No.
A
OD
C
P1I
5.5
P1L
5.5
A
(Straight)
P1M
5.5
C B
P1IR
5.5
P1JR
5.5
P1LR
5.5
(Right-angled)
P1MR
5.5
Barrel Style
Type No.
A
OD
C
P2I
5.5
P2J
5.5
P2L
5.5
A
(Straight)
P2M
5.5
B
C
P2IR
5.5
P2JR
5.5
P2LR
5.5
(Right-angled)
P2MR
5.5
Lock Style
Type No.
A
OD
A
Floating Locking
C
P2S(S761K) 5.53
P2K(761K)
5.53
B
P2C(S760K) 5.53
SWITCHCRAFT original or equivalent P2D(760K)
5.53
B
C
ID
L
Quick Adapter Accessory
2.1
9.5
2.5
9.5
2.5
11.0
2.1
9.5
Available
2.1
11.0
(Current rating: 7.5A max.)
2.5
9.5
2.5
11.0
B
C
ID
L
2.1 9.5
2.1 11.0
2.5 9.5 2.5 11.0
None
2.1
9.5
2.1 11.0
2.5
9.5
2.5 11.0
B
C
ID
L
2.03 12.06 2.54 12.06
None
2.03 9.52
2.54 9.52
Downloaded from Arrow.com.
File Name:GSM18E-SPEC 2024-04-26
18W AC-DC Reliable Green Medical Adaptor
GSM18E series
Min. Pin Style
A
C
B EIAJ equivalent
Center Pin Style
A
C
B
D
EIAJ equivalent
Min. DIN 3 Pin with Lock (male)
1 3
2
KYCON KPPX-3P equivalent
Min. DIN 4 Pin with Lock (male)
23 14
KYCON KPPX-4P equivalent
Min. DIN 4 Pin with Lock (female)
23 14
KYCON KPJX-CM-4S equivalent
DIN 5 Pin (male)
13 425
Stripped and tinned leads
Type No. P3A P3B P3C
Type No. P4A P4B P4C
Type No.
R6B
Type No.
R7B
Type No.
R7BF
Type No.
R1B
Type No.
A
B
C
Quick Adapter
OD
ID
L
Accessory
2.35
0.7 11.0
Available
4.0
1.7
11.0
(Current rating: 5A max.)
4.75
1.7 11.0
A B CD
OD ID
L Center Pin
5.5 3.4 11.0 1.0
Available
(Current rating: 7.5A max.)
6.5 4.4 11.0 1.4
7.4 5.1 11.0 0.6
Pin Assignment
PIN No.
Output
1
+Vo
2
-Vo
Available
(Current rating: 7.5A max.)
3
+Vo
Pin Assignment
PIN No.
Output
1
+Vo
2
-Vo
3
-Vo
4
+Vo
Pin Assignment
PIN No.
Output
1
+Vo
2
-Vo
3
-Vo
4
+Vo
Pin Assignment
PIN No.
Output
1
-Vo
2
-Vo
3
+Vo
4
-Vo
5
+Vo
Pin Assignment
PIN No.
Output
Available
(Current rating: 7.5A max.)
None
Available
(Current rating: 7.5A max.)
L (red)
1 2
1
+Vo
L1 (black) by customer
Length of Land L1 by request
(MW’s standard length, L: 25 mm, L1: 5 mm)
( NOTE: The wire color is for reference only, please refer to the actual
product)
2
-Vo
None
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.
File Name:GSM18E-SPEC 2024-04-26
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>