solis WiFi Stick Datalogger Installation Guide
- June 3, 2024
- solis
Table of Contents
WiFi Stick Datalogger
Quick Installation Manual
Version: 3.6
Delivery Content
- 1 WiFi stick
- 1 WiFi Antenna
- 1 Quick Installation Manual
Install
1.1 Install the datalogger
Connect the datalogger to the corresponding 4-pin COM port of the inverter. A
Solis 5K inverter is used here as an example. Please follow the instructions
below:
Install the datalogger:
- Install the antenna to the datalogger.
- Match the joint,and then insert the datalogger to the inverter COM port.
- Rotate the black ring in clockwise.
NOTE
Only rotate the black ring at the connection end, not rotate the sliver cover.
1.2 Install with multiple inverters
If you need to collect data from multiple inverters, please follow the
inverter user manual to establish a communication connection with the inverter
using the RS485 communication cable in a “daisy chain” manner.
After the datalogger is installed on the inverter, if the inverter is powered
on, you need to set the inverter slave address, the default slave address of
the inverter is 01, and each inverter on the communication circuit needs to be
assigned with different slave address(like 01,02,03,04…).
NOTE
The device must be installed away from the strong magnetic field produced by
large electrical appliances such as microwave oven, refrigerator, telephone,
metal walls, etc. Otherwise, the communication quality may be affected. It may
also be affected by lighting storm.
LED and Button
LED Lights Status:
LED indicators | Description | LED Status | Meanings |
---|---|---|---|
**** Internet Indicators Ti (NET) | Shows the connection status between the | ||
datalogger and the server. | Flashing | Trying to connect with server | |
ON | Successfully connected | ||
OFF | Abnormal connection | ||
**** Inverter COM Indicators (COM) | Shows the connection status between | ||
datalogger and the inverter. | Flashing | Trying to connect with inverter | |
ON | Successfully connected | ||
OFF | Abnormal connection | ||
**** Power Indicator •(PWR) | Shows the power supply status of the | ||
datalogger. | ON | Datalogger is powered up normally | |
OFF | Datalogger is powered up abnormally |
Button Instruction:
The [RESEM button on the back is used for connection. • Short press will send
the data immediately. •Long press for 5 seconds will enter into config mode
for connection router. -Long press for 10 seconds will reset the connection.
The three constantly ON LED lights indicate the datalogger is working
normally.
WiFi Configuration
Step 1: Use you phone to scan the QR code to download and register the Solis Cloud APP. Or directly download from APP Store or Google Play Store by searching “Solis Cloud”.
Step 2: If it is anew datalogger, please configure it first, then click the “WiFi Configuration”.
Unlogged account, click on “More Tools” and select “WiFi Configuration”
If you have logged in, please click “Tool” to enter “WiFi Configuration”
Step 3 : Manually input datalogger SN or Scan the SN on the datalogger.
Step 4: Choose the configuration method, recommended click “Brower Configuration”.
Step 5 : Long press the “Reset” button for 5 seconds until the yellow and
green LEDs are quickly flashing.
Then click the “I’m sure i t is flashing”.
Step 6 : Connect to the datalogger network Solis.
Step 7 : The wireless device(mobile phone or laptop) connects to the
datalogger hotspot(Solis_serial number).
The default password is 123456789.
After that, return to APP.
Step 8 : Click “s”, make sure the phone is connected to router WiFi and switch back to the page to fill in the WiFi password, then move to next step.
Step 9 : Configuration Complete.
Create the Solis Cloud Account
Step 1: Click the “Register”.
Step2: Select Owner or Organization for emai address registration.
Step3: Enter the email te get the verification code, than enter your account and password, last click the “Register”.
Create Plant
Step1: Enter the main page o f Solis Cloud APP, click “+”at the top right corner and select “Add plant”.
Step 2 : Input the information o f the plant as required.
Then click “Done”.
Step 3: Confirm the plant information.
Click “Create plant”.
Step 4: Click “View plant ” to enter the plant homepage , then add the datalogger.
Step 5: Scan the datalogger SN QR code or manually input it.
Note: Scan the datalogger SN, NOT the inverter SN.
Step 6: Plant creation succeeds. Click “Continue to bind” to check the monitoring data. If the plant has multiple dataloggers, please click “View Plant”.
FCC Certification
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
FCC warning:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Contact
Please contact us if you have any technical problems in terms of the product.
Please provide the following information as well:
Inverter SN
Datalogger SN
Problem Description