solis 10 Minutes Voltage Set
10 MINUTES VOLTAGE SET
- STEP 1: Press Enter on the inverter screen.
- STEP 2: Use Up/Down keys to go to advanced settings and press Enter.
- STEP 3: Press Down key twice and Up key once, to type the password as 0010. Then press Enter.
- STEP 4 : Use the up/down keys to scroll to Grid ON/ Grid OFF. Then press Enter.
- STEP 5: Select the Grid OFF option and press Enter. You will see the operation light turn OFF.
- STEP 6: Press Up/Down key until you find ‘STD Mode Settings’. Press Enter.
- STEP 7: Press Up/Down key until you see ’10 mins Voltage Set’. Press Enter.
- STEP 8: You can change the voltage value by pressing the Up key (By default, the 10 mins voltage set is 255V or 257V). You can set a maximum of 258 Volts. Press Enter to Save.
- STEP 9: Now turn the Grid ON in Advanced Settings. (Go to Advanced Settings again by pressing ESC thrice < Set password 0010 < Go to Grid ON/Grid OFF < Select Grid ON < Press Enter).
“ALL DONE” HAVE A GOOD DAY!
- Website: www.solisinverters.com.au