Lithium Series Dual 48V 5.1kWh Solis Inverter User Guide

June 3, 2024
solis

Lithium Series Dual 48V 5.1kWh Solis Inverter

Lithium-Series-Dual-48V-5-1kWh-Solis-Inverter-PRODUCT

Solis Inverter Configuration

For the configuration of the inverter, it is necessary to select USER-Define in the Battery Module within Battery Select.Lithium-Series-Dual-48V-5-1kWh-
Solis-Inverter-FIG 1

It will be verified that the communication is correct if the main screen shows CAN OK between the battery and the inverter. Also, on page 3 of Information the BMS Status must appear as NORMALLithium-Series-Dual-48V-5-1kWh-Solis-
Inverter-FIG 2

Battery on and off

To turn on the battery, press the power button for a few seconds. The BMS will start and the LED will light up.
To turn off the batteries, press the power button for more than 5 seconds.

Configuration Lithium Series Dual 48V 5.1 kWh

Each module has 5 DIP switches (SW1, SW2, SW3, SW4, and SW5) that will be set differently based on system requirements, battery connection, and inverter .Lithium-Series-Dual-48V-5-1kWh-Solis-Inverter-FIG 3

SW1 is for the communication protocol with the inverter. If the CAN protocol is used, 1 and 2 must be ON.
SW4 and SW5 are for communication with the inverter and depend on the communication cable and protocol of the inverter.
If a pin-to-pin cable is used, the DIP settings are as follows:Lithium-
Series-Dual-48V-5-1kWh-Solis-Inverter-FIG 4

DIPS FOR COMMUNICATION ON SERIES

SW2 and SW3 are for communication between batteries.Lithium-Series-Dual-
48V-5-1kWh-Solis-Inverter-FIG 5Lithium-Series-Dual-48V-5-1kWh-Solis-Inverter-FIG
6 Lithium-Series-Dual-48V-5-1kWh-Solis-
Inverter-FIG 7 Lithium-Series-Dual-48V-5
-1kWh-Solis-Inverter-FIG 8

Make sure DIP switch SW2 is selected correctly. If the battery is connected in parallel mode, but DIP8 is in the ON position, a serious and dangerous fault may occur. On the other hand, if the battery is connected in serial mode, but SW2 DIP8 is in the OFF position, a serious and dangerous fault may occur.

DIPS FOR COMMUNICATION ON PARALLEL

SW2 and SW3 are for communication between batteries.Lithium-Series-Dual-
48V-5-1kWh-Solis-Inverter-FIG 9 Lithium-Series-Dual-48V-5-1kWh-Solis-Inverter-FIG
10 Lithium-Series-Dual-48V-5-1kWh-Solis-
Inverter-FIG 11 Lithium-Series-Dual-48V-5
-1kWh-Solis-Inverter-FIG 12

Make sure DIP switch SW2 is selected correctly. If the battery is connected in parallel mode, but DIP8 is in the ON position, a serious and dangerous fault may occur. On the other hand, if the battery is connected in serial mode, but SW2 DIP8 is in the OFF position, a serious and dangerous fault may occur.

Wiring Configuration

The cable needed to make the connection is the RJ45. This is a cable made up of 8 smaller cables each with a different color configuration.Lithium-
Series-Dual-48V-5-1kWh-Solis-Inverter-FIG 13

A standard pin-to-pin cable with an RJ45 connector should be used.

For the connection between the inverter and the battery, the RJ45 cable will be connected to the ‘’Inverter’’ port of the battery, and to the CAN port of the inverterLithium-Series-Dual-48V-5-1kWh-Solis-Inverter-FIG
16