MEAN WELL APV-16-5 Series 16W Single Output Switching Power Supply Owner’s Manual
- September 16, 2024
- MEAN WELL
Table of Contents
MEAN WELL APV-16-5 Series 16W Single Output Switching Power Supply
Product Usage Instructions
Installation
- Ensure proper ventilation around the power supply unit.
- Connect the input according to the specified voltage range and frequency.
- Connect the output to your device following the correct DC voltage and current ratings.
- Mount the power supply securely using appropriate hardware.
Maintenance
- Regularly check for any signs of damage or overheating.
- Keep the power supply clean and free from dust accumulation.
- Do not attempt to repair or modify the power supply yourself; seek professional assistance if needed.
Frequently Asked Questions
Q: What should I do if the power supply overheats?
A: Ensure proper ventilation and check for any obstructions blocking airflow around the unit. If the issue persists, contact customer support.
Q: Can I use this power supply with devices that require different voltages?
A: No, it is important to match the output voltage of the power supply with the requirements of your device to prevent damage.
Q: How can I test if the power supply is functioning correctly?
A: Use a multimeter to measure the output voltage and current to verify they match the specifications provided in the user manual.
User’s Manual
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Features
- Constant voltage design
- Universal AC input / Full range
- Protections: Short circuit / Over load / Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- Small and compact size
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- IP42 design
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note.7
- 100% full load burn-in test
- Low cost, high reliability
- A Maare warrantu.
SPECIFICATION
MODEL | APV-16-5 | APV-16-12 | APV-16-15 | APV-16-24 |
---|
OUTPUT
| DC VOLTAGE| 5V| 12V| 15V| 24V
RATED CURRENT| 2.6A| 1.25A| 1A| 0.67A
CURRENT RANGE| 0 ~ 2.6A| 0 ~ 1.25A| 0 ~ 1A| 0 ~ 0.67A
RATED POWER| 13W| 15W| 15W| 16.08W
RIPPLE & NOISE (max.) **Note.2| 100mVp-p| 120mVp-p| 120mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.3| ±5.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±2.0%
SETUP, RISE TIME Note.6| 1500ms, 30ms / 230VAC
1500ms,30ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 20ms/230VAC 12ms/115VAC at full load
INPUT
| VOLTAGE RANGE Note.4| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 76%| 80%| 81%| 83%
AC CURRENT| 0.3A/230VAC 0.5A/115VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=250μs measured at 50% Ipeak)
at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 13 units (circuit breaker of
type B) / 22 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION
| OVER LOAD| Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16V| 17.5 ~ 21V| 27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS Note.8| UL8750,CSA C22.2 No.250.0-08, BIS IS15885(except for 15V),EAC TP TC 004,IP42 ,
BS EN/EN 62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS
EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN55035,BS
EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020
OTHERS
| MTBF| 7265.5K hrs min. Telcordia SR-332 (Bellcore) ;
1128.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 774029mm (LWH)
PACKING| 0.1Kg; 120pcs/14Kg/1.06CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details. Please connect L line to the positive pole and N line to the negative pole under DC input.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://[www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)](http://www.meanwell.com/Upload/PDF/EMI_statement_en.pdf))
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. This product is not intended for LED lighting luminaire applications in the EU and China.(In the EU and China the LPF/NPF/XLG/XLC/XLN series
are recommended.)
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
9. Products sourced from the Americas regions may not have the ENEC/BIS logo. Please contact your MEAN WELL sales for more information.
10. For any application note and IP water proof function installation caution, please refer our user manual before using. https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)
※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Mechanical Specification
Block Diagram
Derating Curve