Specifications

  • Model: APC-16-350, APC-16-700

  • Output:

    • Rated Current: 350mA
    • DC Voltage Range: 12~48V
    • Rated Power: 16.8W
    • Ripple & Noise (max.): 300mVp-p
  • Input:

    • Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
    • Frequency Range: 47 ~ 63Hz
  • Efficiency: 84% (APC-16-350), 83% (APC-16-700)

  • Working Temperature: -30 ~ 70°C

  • Safety & EMC:

    • Compliance to UL8750, CSA C22.2 No.250.0-08, BIS IS15885, EAC
      TP TC 004, BS EN/EN 62368-1

    • Withstand Voltage: I/P-O/P: 3.75KVAC

  • Dimension: 774029mm (LWH)

Product Usage Instructions

Connection

Connect the L line to the positive pole and the N line to the
negative pole under DC input.

Power Supply Operation

  1. Ensure input voltage is within the specified range.

  2. Connect the output load within the rated current and voltage
    range.

  3. Monitor temperature to ensure it remains within the working
    temperature limits.

Safety Precautions

  • Avoid exposure to moisture or extreme temperatures.

  • Do not operate the power supply beyond the specified input
    voltage range.

  • Ensure proper grounding for safety.

Frequently Asked Questions (FAQ)

Q: What is the maximum number of power supplies that can be

connected to a 16A circuit breaker?

A: 13 units for circuit breaker type B and 23 units for circuit
breaker type C at 230VAC.

Q: What should I do if the power supply operates outside the

specified temperature range?

A: Ensure proper ventilation and cooling to bring the
temperature within the recommended working temperature limits.

“`

16W Single Output Switching Power Supply

APC-16 series

SPECIFICATION

User’s Manual

LPS

IP42

IS 15885(Part 2/Sec13)

THOMAS SAMUEL

THOMAS SAMUEL

R-41027766

MODEL

APC-16-350

APC-16-700

OUTPUT

RATED CURRENT

350mA

DC VOLTAGE RANGE

12~48V

RATED POWER

16.8W

RIPPLE & NOISE (max.) Note.2 300mVp-p

VOLTAGE TOLERANCE Note.3 ±5.0%

CURRENT ACCURACY

±8.0%

700mA 9~24V 16.8W 250mVp-p

LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)

±1.0% ±3.0% 3000ms, 200ms / 230VAC 3000ms, 200ms / 115VAC at full load 20ms/230VAC 12ms/115VAC at full load

INPUT

VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY(Typ.)

84%

83%

AC CURRENT INRUSH CURRENT(Typ.)

0.3A/230VAC;0.5A/115VAC COLD START 45A(twidth=210s measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

13 units (circuit breaker of type B) / 23 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

PROTECTION OVER VOLTAGE WORKING TEMP.

50.4~ 60V Protection type : Shut off o/p voltage, clamping by zener diode -30 ~ 70(Refer to “Derating Curve”)

27.6~ 33.5V

WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT

20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH ±0.2%/ (0 ~ 50)

SAFETY &
EMC (Note 5)

VIBRATION SAFETY STANDARDS Note.7 WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL8750,CSA C22.2 No.250.0-08, BIS IS15885, EAC TP TC 004,BS EN/EN 62368-1 approved
I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3, EAC TP TC 020

OTHERS

EMC IMMUNITY MTBF DIMENSION PACKING

Compliance to BS EN/EN55035,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020 6411.4K hrs min. Telcordia SR-332 (Bellcore) ; 1092.9K hrs min. MIL-HDBK-217F (25) 774029(LWH) 0.1Kg; 120pcs/14Kg/1.06CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristic for more details.Please connect L line to the positive pole and
N line to the negative pole under DC input. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 6. This product is not intended for LED lighting luminaire applications in the EU and China.(In the EU and China the LPF/NPF/XLG/XLC/XLN series are recommended.) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name: APC-16-SPEC 2024-08-01

16W Single Output Switching Power Supply
Mechanical Specification
90 82.5 77

AC/N(Blue) AC/L(Brown)

UL1569 18AWG 150±10

31 T case
T case: Max. Case Temperature

APC-16 series
Unit:mm

150±10 UL1569 20AWG

+V(Red) -V(Black)

40 15.5
19 29

Block Diagram

I/P

EMI FILTER

RECTIFIERS

POWER SWITCH-
ING
PWM CONTROL

RECTIFIERS &
FILTER

DETECTION CIRCUIT

fosc : 67KHz
+V -V

Derating Curve

Static Characteristics

100
80
60 50 40
20
-30

0 10 20 30

40

50 60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40

90 100 200 210 220 230 240 250

264

INPUT VOLTAGE (VAC) 60Hz

File Name: APC-16-SPEC 2024-08-01

LOAD (%) LOAD (%)