Specifications:

  • Product Name: WaveLinx PRO Industrial Fixture Mount High Bay /
    Low Bay Sensor

  • Compatibility: WaveLinx Mobile App, IEEE 802.15.4

  • Device Security: WaveLinx PRO

  • Installation Heights: Up to 40 feet

  • Coverage Patterns: Up to 5000 square feet

  • Power Source: Co-located light fixture

Product Usage Instructions:

Installation:

  1. Ensure the industrial light fixture is equipped with the 4-pin
    Zhaga Book 18 compliant socket.

  2. Integrate the sensor into the fixture without the need for
    tools.

  3. Ensure proper connectivity with the WaveLinx PRO system.

Configuration:

Use the WaveLinx Mobile application to configure the sensor:

  • Map the sensor to specific areas or control zones.
  • Select occupancy or vacancy mode.
  • Set occupied and unoccupied light levels.
  • Adjust the hold time as needed.

FAQ:

Q: What is the power source for the sensor?

A: The sensor receives power from its co-located light fixture,
eliminating the need for battery replacement.

Q: What is the coverage area of the sensor?

A: The sensor offers coverage patterns up to 5000 square feet,
based on its field of view specifications.

Q: Is additional equipment required for full

functionality?

A: Yes, the WaveLinx PRO Industrial Fixture Mount High Bay / Low
Bay Sensor requires a WaveLinx Area Controller (WAC) for complete
functionality within the WaveLinx connected lighting system.

“`

Project Prepared by

Catalog # Notes

Type Date

4-pin Zhaga Book 18 socket

WaveLinx
PRO Industrial Fixture Mount High Bay/Low Bay Sensor (WPS*)
Motion and Closed Loop Daylighting including Field Installed Aisle Shield
Typical Applications Industrial · Manufacturing

Interactive Menu
· Order Information page 2 · Additional Resources page 3 · Connected Systems page 5 · Product Warranty

Product Certification*

Part 15/ECES-003

· Meets latest ASHRAE Standard 90.1 requirements · Meets latest IECC requirements · Meets latest CEC Title 24 requirements

Product Features

Compatibility

WaveLinx Mobile App

IEEE 802.15.4

Device Security

WaveLinx PRO

Overview

Customer Security

Daylighting Control

Occupancy Sensor

The PRO Industrial Fixture Mount High Bay / Low Bay Sensor offers passive infrared (PIR) occupancy and a photocell for closed loop daylighting. WaveLinx PRO industrial sensors offer installation heights up to 40 feet and have coverage
patterns up to 5000 square feet (see sensor specifications – field of view). When part of WaveLinx PRO, the sensor operates on a wireless mesh network based on IEEE 802.15.4 standards.

The sensors offer simple tool-less integration into WaveLinx PRO industrial light fixtures equipped with the 4-pin Zhaga Book 18 compliant socket. Once installed, sensors receive power from their co-located light fixture with no batteries to replace. The sensor in combination with the WaveLinx Mobile application allows you to gain considerable energy savings from occupancy and daylight sensing lighting control. The WaveLinx Mobile application allows you to map the sensor to
any area or control zone, select occupancy or vacancy, occupied and unoccupied light levels and set the hold time.

Product Features & Benefits
· Models suitable for High bay (up to 40ft / 45ft major motion) and Low bay (up to15ft) applications · Out of the box functionality: Occupied to Full, Unoccupied to 10%, daylighting disabled · Passive Infra-Red (PIR) motion sensor with coverage up to 5000 square feet · Integrated photocell for closed loop daylight harvesting · Software configurable settings with WaveLinx Mobile application · Simple tool-less twist lock fixture connection via 4-pin Zhaga Book 18 socket · IP66 rating for warehouse and manufacturing environments · Energy calculations available through WaveLinx CORE

*T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification.
PS503095EN page 1
July 2024

WaveLinx

PRO Industrial Fixture Mount High Bay / Low Bay Sensor

Order Information
WaveLinx PRO Industrial Fixture Mount High Bay / Low Bay Sensors are accessories to the WaveLinx connected lighting (WCL) system and requires a WaveLinx Area Controller (WAC) for full functionality.
WaveLinx PRO Industrial Fixture Mount High Bay / Low Bay Sensors are used to provide occupancy and daylight dimming to spaces from the industrial light fixture. For energy code compliance, additional sensors may not be required.

Catalog Number

Catalog #

Description

WPS2-WH

WaveLinx PRO Industrial Fixture Mount Low Bay Sensor, White, 7 – 15ft (2.1 – 4.5m)

WPS4-WH
Notes For use with industrial light fixtures equipped with the WaveLinx PRO Zhaga compliant 4-pin socket only.

WaveLinx PRO Industrial Fixture Mount High Bay Sensor, White, 15 – 40ft (4.5 – 12.2m)
Notes When used as a component in the WaveLinx connected lighting system, WaveLinx PRO system design best practices (including WaveLinx Area Controller placement, line of sight distances, number of hops, etc.) must be followed. High mount models accommodate mounting height to 45ft (13.7m) for major motion (vehicles, fork trucks, etc.) – may not detect minor motion of people depending on conditions.

Required Accessories
All WaveLinx connected lighting (WCL) system accessories require at least one WaveLinx Area Controller (WAC2) for communications. Ensure the bill of material includes one of the following components.

Catalog Number
Catalog Number WAC2-POE WAC2-120
Optional Accessories For connection to 120VAC outlets.

WaveLinx Area Controller G2, PoE powered WaveLinx Area Controller G2 with 120VAC to PoE Injector

Description

Catalog Number

Catalog Number WPOE2-120

120VAC to PoE Injector

Product Specifications
Mechanical Size: Base Diameter 3.2″ (82mm) Height: 1.6″ (41mm) Weight: 0.20 lbs (0.10 kg) Environment:
· Operating temperature: -40°F to 131°F (-40°C to 55°C) Sensor passive infrared (PIR) performance may become exceedingly sensitive below -4°F (-20°C) Note: WaveLinx Area Controller should be installed in an indoor conditioned envirionment, preferably with line of sight through a window to one or more WaveLinx PRO wireless devices.
· Storage temperature: -40°F to 158°F (-40°C to 70°C) · Relative humidity operating: 0% to 95% non-condensing · Default behavior intended for indoor use only Mounting: Fixture mount Mounting Height: High bay up to 40ft (12m) and Low bay up to15ft (5m) Color: White Housing: UV stabilized plastic Ingress protection: IP66 Light Sensor Detector Shields: Field configured shield included Daylighting Installation: · Ensure that sensor is not looking directly at artificial light · Ensure that sensor is not obstructed · Use configurable lens mask for desired directionality
Electrical Input Requirements: Fixture connection via 4-pin Zhaga Book 18 socket
Software Specifications · Any number of sensors can be mapped to any number of zones · Mobile app configuration for Occupancy/Vacancy · Remote Hold Time settings fully configurable via mobile app · Mobile app configuration of Occupied and Unoccupied light levels · Energy calculations available through WaveLinx CORE

Description
Wireless Specifications Radio: 2.4GHz Standard: IEEE 802.15.4 Transmitter Power: + 8dBm Range: Sensor to sensor; 160ft (49m) LOS (best practice) System Performance Maximum number of nodes supported: 200 per WaveLinx Area Controller (best practice 150 devices) Standards/Ratings · cULus Listed – Energy Management Equipment (UL916) · FCC Part 15/ECES-003 · Meets latest ASHRAE Standard 90.1 requirements · Meets latest IECC requirements · Meets latest CEC Title 24 requirements Warranty Five year warranty standard
T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification. PS503095EN page 2 July 2024

WaveLinx
Dimensional Details

PRO Industrial Fixture Mount High Bay / Low Bay Sensor

1.6″ [42mm]

Mounting Height
40′ [12.2m] (45′ [13.7m] major motion)

3.2″ [81mm] TOP

1.5″ [38mm] SIDE

15′ [4.6m]

Installation
Both the WPS2 and WPS4 easily install into WaveLinx PRO-ready LED fixtures equipped with Zhaga Book 18 4-pin sockets. Sensor connection is enabled via the simply twistlock connection and provides immediate out-of-the-box functionality.
Removal

Installation

PS503095EN page 3
July 2024

WaveLinx
Field of View – Low Bay

TOP VIEW:

24ft [7.3m]

PRO Industrial Fixture Mount High Bay / Low Bay Sensor
CL

15ft [4.5m]

5ft [1.5m]

0

CL

5ft [1.5m] 15ft [4.5m]

24ft [7.3m]

SIDE VIEW:
0

8ft [2.4m]

15ft [4.6m]

24ft [7.3m]

Note: The “beam” pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

15ft

5ft

0

[4.5m] [1.5m]

5ft [1.5m]

15ft [4.5m]

24ft [7.3m]

PS503095EN page 4
July 2024

WaveLinx
Field of View – High Bay

PRO Industrial Fixture Mount High Bay / Low Bay Sensor

TOP VIEW:

50ft [15.2m]

CL

35ft [10.6m] 21ft [6.4m] 13ft [4.0m] 0
13ft [4.0m] 21ft [6.4m] 35ft [10.6m] 50ft [15.2m] SIDE VIEW:
0

CL
Note: The “beam” pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

20ft [6.1m]

30ft [9.1m]

40ft

[12.2m]

50ft

35ft

21ft 13ft

0

13ft 21ft

35ft

50ft

[15.2m] [10.6m] [6.4m] [4.0m] [4.0m] [6.4m] [10.6m] [15.2m]

High mount models accommodate mounting height to 45ft (13.7m) for major motion (vehicles, fork trucks, etc.) – may not detect minor motion of people depending on conditions.

PS503095EN page 5
July 2024

WaveLinx

PRO Industrial Fixture Mount High Bay / Low Bay Sensor

System Diagram:
This diagram shows the main components of the WaveLinx connected lighting system with CAT and PRO devices.
The PRO devices communicate using wireless mesh technology based on the IEEE 802.15.4 standard. A PoE LAN connection for each WaveLinx Area Controller (WAC) is required for power and data access to the building lighting network.
The CAT devices communicate over the category 5 based communication bus and control the light fixtures using a relay (on/off) and 0-10V output (dim/raise).
WaveLinx Area Controllers (WAC) communicate with WaveLinx CORE Apps over the Ethernet network.

View WaveLinx Network
and IT Guidance Technical Guide

Smart Spaces Apps

CORE Admin

CORE Lighting

CORE Locate

CORE Insights

CORE Insights on Cloud

Networked Relay Panel

WaveLinx CAT

Wired

1

2

Wallstation

3 4

Ceiling Sensor
Dimming Switchpack or Emergency Switchpack
Contact Closure or Sensor Interface

WaveLinx CORE
Touchscreen

CORE Pro on-prem enterprise management software

PoE Power
Area Controller Area Hub

Access Point
WaveLinx Mobile App
Wireless

Relay Switchpack

Ceiling Sensor

Wired & Wireless
Same set of tools and features

Relay Switchpack with Contact Closure Input

Integrated Industrial Fixtures

Wallstation (AC or Battery)

Controlled Receptacle

Building Automation
System
BACnet Router
Firewall

WaveLinx PRO

Tilemount Sensor
Integrated Ambient Fixtures
Integrated Outdoor Fixtures

RTLS Tag

KEY
Ethernet (IEEE 802.3)
WaveLinx CAT (CAT5)
Bluetooth (IEEE 802.15.1)

WaveLinx PRO (IEEE 802.15.4)
WiFi (IEEE 802.11)

Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

© 2024 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions subject to change without notice.

Control Systems
· WaveLinx
PS503095EN page 6
July 2024

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

COOPER Lighting User Manuals

Related Manuals