HORMANN Roller and High Speed Folding Doors Instruction Manual

August 24, 2024
HORMANN

HORMANN Roller and High Speed Folding Doors

Specifications:

  • Door sizes: Internal and external
  • Speed: Max. opening approx. m/s, Max. closing approx. m/s
  • Security equipment: Glazing, Safety equipment
  • Wind load resistance: EN 12424, EN 12425, EN 13241-1, ISO 12567-1
  • Door leaf: Self-supporting, Galvanized, Powder-coated, Stainless steel V2 A

Product Usage Instructions

Door Installation:

  1. Measure the structural opening width and height for proper door fit.
  2. Install the side guides according to the space required for fitting and dismantling the operator.
  3. Position the lintel height to ensure smooth operation of the door.

Operating the Door:

  1. Use the Open-Stop-Close button for regular door operation.
  2. In case of emergency, use the provided Emergency crank handle or Emergency hand chain.
  3. Ensure that the UPS in a plastic cabinet is connected to maintain functionality during power outages.

Maintenance:

  1. Regularly inspect the door leaf, side guides, and safety equipment for any damage.
  2. Keep the glazing clean for optimal visibility.
  3. Lubricate moving parts as recommended by the manufacturer.

FAQ:

Q: What should I do if the door gets stuck during operation?
A: In case of a door malfunction, use the Emergency crank handle or Emergency hand chain to manually open or close the door.

Q: Can I adjust the opening and closing speed of the door?
A: Yes, you can adjust the opening and closing speed using the control panel provided with the door.

Roller doors and high-speed folding doors

NEW: The space-saving high-speed roller door V 3010 for areas without draughts

Fitting data
Issue 01.03.2021

Hörmann roller doors and high-speed folding doors A broad programme for inside and outside

From low-cost design models to secure night doors
Hörmann roller doors and high-speed folding doors are distinguished by high- quality materials and secure long-term functionality. Roller doors and high- speed folding doors are used indoors and outdoors. Roller doors and high-speed folding doors optimise the flow of traffic, improve the room climate and save energy.
Hörmann roller doors and high-speed folding doors comply with strict European safety requirements.

High-speed roller door V 3010

Technical data

  V 3010
Use Internal door
  External door
Door sizes Maximum width LDB
  Maximum height LDH
  Minimum width (structural opening)
  Minimum height (structural opening)
Speed Control contactor, 400 V, 3-phase
   
Security equipment EN 13241
Wind load resistance EN 12424
   
   
   
   
Thermal insulation EN 13241-1, ISO 12567-1
without glazing, with Thermoframe ––
Thermal insulation value in W/(m²·K) EN 13241-1, ISO 12567-1
Resistance to water penetration EN 12425
Air permeability EN 12426
Acoustic insulation EN ISO 717-1, EN ISO 10140-1,

EN ISO 10140-2

| ––
Door construction| Self-supporting| ●
Material| Galvanized| ●
 | Powder-coated| O
 | Stainless steel V2 A| O
Door leaf| UPVC curtain                                     1,0 mm| ●
 | Steel pipe| ––
 | Fibreglass pipe| ●
 | Flexible side guide| ––
 | Side guide made of polyethylene| ●
Glazing| Elongated windows| ––
 | Rectangular windows| O
Safety equipment| Soft bottom edge| ––
 | Photocell SAFETIME double safety patent system| ●
Operator and control| Inversion relay control / frequency converter control|
 | Connecting voltage                             1-phase, 1 – 230 V, N, PE| O
 | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button| ●
 | AK E 370 M-I (inversion relay)| ●
 | AK E 370 M (inversion relay)| O
 | BK 370 M FUE-1 (frequency converter)| O
Emergency opening| Emergency crank handle| ●
 | Emergency hand chain| ––
 | UPS in a plastic cabinet (220 V, 1-phase)| O
Suitable for temperatures from °C to °C|  | +5 °C to +40 °C
● = Standard                    O = Optional|  |

The high-speed roller door for areas without draughts

  • A Side guide in front of the opening
  • B Side guide in the opening
  • BPA Space required to fit and dismantle the operator
  • LDB Clear passage width
  • LDH Clear passage height
  • MFR Space for fitting the door
  • S Lintel height

High-speed folding doors

Technical data

  F 4010 Cold
Use Internal door
  External door
Door sizes Maximum width LDB
  Maximum height LDH
  Minimum width (structural opening)
  Minimum height (structural opening)
Speed Inversion relay, 400 V, 3-phase
   
Security equipment EN 13241
Wind load resistance EN 12424
   
   
   
   
Thermal insulation EN 13241-1, ISO 12567-1
without glazing, with Thermoframe
Thermal insulation value in W/(m²·K) EN 13241-1, ISO 12567-1
Resistance to water penetration EN 12425
Air permeability EN 12426
Acoustic insulation EN ISO 717-1, EN ISO 10140-1,

EN ISO 10140-2

|  | ––
Door construction| Self-supporting|  | ●
Material| Galvanized|  | ––
 | Powder-coated|  | ●
 | Stainless steel V2 A|  | O
Door leaf| UPVC curtain| 1,0 mm| ●
 | Spring steel pipe|  | ––
 | Fibreglass pipe|  | ●
 | Tension and safety belts|  | ●
 | Flexible guides|  | ●
 | Flexible guides in the side elements|  | ––
 | Side guide made of polyethylene|  | ––
 | Multi-layer ISO material| 3.0 mm| ●
Glazing| Oval and rectangular windows|  | ––
 | Without window|  | ––
Safety equipment| Light grille|  | ––
 | Soft bottom edge|  | ––
 | Photocells|  | ●
Operator and control| Frequency converter control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| O
 | Inversion relay control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button|  | ●
 | AK E (inversion relay)|  | ●
 | AK 500 FUE-1 (frequency converter)|  | O
 | AK E 2500 M-I (inversion relay)|  | ––
 | AK E-700 M (inversion relay)|  | ––
 | AK E-750 M (inversion relay)|  | O
 | Electronic limit switch DES|  | ●
Emergency opening| Emergency crank handle|  | ––
 | Emergency hand chain|  | ●

● = Standard O = Optional

High-speed folding door F 4010 Cold

The insulated deep freeze door

  • BPA Space required to fit and dismantle the operator
  • LDB Clear passage width
  • LDH Clear passage height
  • MFR Space for fitting the door

High-speed folding doors

Technical data

● = Standard O = Optional 1) Optionally up to class 4 2) F 6010 ISO optionally from –30 °C up to +40 °C

Attention!
F 6010 ISO is not a cold door. The frames are not heated.

High-speed folding door F 6010 / F 6010 Iso
For fast door opening up to wind load class 4

  • A Side guide in front of the opening
  • B Side guide in the opening
  • BPA Space required to fit and dismantle the operator
  • LB Clear width
  • LDB Clear passage width
  • LDH Clear passage height
  • MFR Space for fitting the door side element

High-speed folding door F 6010 / F 6010 Iso
For fast door opening up to wind load class 4

  • BPA Space required to fit and dismantle the operator
  • LDB Clear passage width
  • LDH Clear passage height
  • MFR Space for fitting the door

High-speed folding doors

Technical data

  F 8005
Use Internal door
  External door
Door sizes Maximum width LDB
  Maximum height LDH
  Minimum width (structural opening)
  Minimum height (structural opening)
Speed Control contactor, 400 V, 3-phase
   
Security equipment EN 13241
Wind load resistance EN 12424
   
   
   
   
   
   
Thermal insulation EN 13241-1, ISO 12567-1
without glazing, with Thermoframe ––
Thermal insulation value in W/(m²·K) EN 13241-1, ISO 12567-1
Resistance to water penetration EN 12425
Air permeability EN 12426
Acoustic insulation EN ISO 717-1, EN ISO 10140-1,

EN ISO 10140-2

|  | ––
Door construction| Self-supporting|  | ––
Material| Galvanized|  | ––
 | Powder-coated|  | ●
 | Stainless steel V2 A|  | O
Door leaf| UPVC curtain| 1,0 mm| ●
 | Galvanized steel pipe|  | ●
 | Fibreglass pipe|  | ––
 | Tension and safety belts|  | ●
 | Flexible guides|  | ––
 | Flexible guides in the side elements|  | ●
 | Side guide made of polyethylene|  | ––
 | Multi-layer ISO material| 3.0 mm| ––
Glazing| Oval windows|  | O
 | Without window|  | ●
Safety equipment| Light grille|  | ––
 | Soft bottom edge|  | ––
 | Photocells|  | ●
Operator and control| Frequency converter control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| ––
 | Inversion relay control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 230 V, N, PE| ●
 |  | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button|  | ●
 | AK E (inversion relay)|  | ––
 | AK 500 FUE-1 (frequency converter)|  | ––
 | AK E 2500 M-I (inversion relay)|  | ––
 | AK E-700 M (inversion relay)|  | ●
 | AK E-750 M (inversion relay)|  | ––
 | Electronic limit switch DES|  | ––
Emergency opening| Emergency crank handle|  | ––
 | Emergency hand chain|  | ––

● = Standard O = Optional

High-speed folding door F 8005
For large exterior door openings up to 8 m wide

  • LDB Clear passage width
  • LDH Clear passage height
  • MFR Space for fitting the door side element

High-speed folding doors
Technical data

  F 14005
Use Internal door
  External door
Door sizes Maximum width LDB
  Maximum height LDH
  Minimum width (structural opening)
  Minimum height (structural opening)
Speed Control contactor, 400 V, 3-phase
   
Security equipment EN 13241
Wind load resistance EN 12424
   
   
   
   
   
   
Thermal insulation EN 13241-1, ISO 12567-1
without glazing, with Thermoframe ––
Thermal insulation value in W/(m²·K) EN 13241-1, ISO 12567-1
Resistance to water penetration EN 12425
Air permeability EN 12426
Acoustic insulation EN ISO 717-1, EN ISO 10140-1,

EN ISO 10140-2

|  | ––
Door construction| Self-supporting|  | ––
Material| Galvanized|  | ––
 | Powder-coated|  | ●
 | Stainless steel V2 A|  | O
Door leaf| UPVC curtain| 1,0 mm| ●
 | Galvanized steel pipe|  | ––
 | Fibreglass pipe|  | ●
 | Tension and safety belts|  | ●
 | Flexible guides|  | ––
 | Flexible guides in the side elements|  | ––
 | Side guide made of polyethylene|  | ––
 | Multi-layer ISO material| 3.0 mm| ––
Glazing| Oval windows|  | O
 | Without window|  | ●
Safety equipment| Light grille|  | ––
 | Soft bottom edge|  | ●
 | Photocells|  | ●
Operator and control| Frequency converter control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| ––
 | Inversion relay control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 230 V, N, PE| ●
 |  | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button|  | ●
 | AK E (inversion relay)|  | ––
 | AK 500 FUE-1 (frequency converter)|  | ––
 | AK E 2500 M-I (inversion relay)|  | ––
 | AK E-700 M (inversion relay)|  | ●
 | AK E-750 M (inversion relay)|  | ––
 | Electronic limit switch DES|  | ––
Emergency opening| Emergency crank handle|  | ––
 | Emergency hand chain|  | ––

● = Standard O = Optional

High-speed folding door F 14005
For large exterior door openings up to 14 m wide

  • Max. 70 m²
  • LDB Clear passage width
  • LDH Clear passage height
  • MFR Space for fitting the door side element

Hörmann: Quality without Compromise

Hörmann is the only manufacturer worldwide that offers you a complete range of all major building products from one source.
We manufacture in highly-specialised factories using the latest production technologies. The close-meshed network of sales and service companies throughout Europe, and activities in the USA and Asia, make Hörmann your strong partner for first-class building products, offering “Quality without Compromise”.

GARAGE DOORS
OPERATORS
INDUSTRIAL DOORS
LOADING EQUIPMENT
HINGED DOORS
DOOR FRAMES

www.samsondoors.co.uk

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals