HORMANN Roller and High Speed Folding Doors Instruction Manual
- August 24, 2024
- HORMANN
Table of Contents
HORMANN Roller and High Speed Folding Doors
Specifications:
- Door sizes: Internal and external
- Speed: Max. opening approx. m/s, Max. closing approx. m/s
- Security equipment: Glazing, Safety equipment
- Wind load resistance: EN 12424, EN 12425, EN 13241-1, ISO 12567-1
- Door leaf: Self-supporting, Galvanized, Powder-coated, Stainless steel V2 A
Product Usage Instructions
Door Installation:
- Measure the structural opening width and height for proper door fit.
- Install the side guides according to the space required for fitting and dismantling the operator.
- Position the lintel height to ensure smooth operation of the door.
Operating the Door:
- Use the Open-Stop-Close button for regular door operation.
- In case of emergency, use the provided Emergency crank handle or Emergency hand chain.
- Ensure that the UPS in a plastic cabinet is connected to maintain functionality during power outages.
Maintenance:
- Regularly inspect the door leaf, side guides, and safety equipment for any damage.
- Keep the glazing clean for optimal visibility.
- Lubricate moving parts as recommended by the manufacturer.
FAQ:
Q: What should I do if the door gets stuck during operation?
A: In case of a door malfunction, use the Emergency crank handle or
Emergency hand chain to manually open or close the door.
Q: Can I adjust the opening and closing speed of the door?
A: Yes, you can adjust the opening and closing speed using the control
panel provided with the door.
Roller doors and high-speed folding doors
NEW: The space-saving high-speed roller door V 3010 for areas without draughts
Fitting data
Issue 01.03.2021
Hörmann roller doors and high-speed folding doors A broad programme for inside and outside
From low-cost design models to secure night doors
Hörmann roller doors and high-speed folding doors are distinguished by high-
quality materials and secure long-term functionality. Roller doors and high-
speed folding doors are used indoors and outdoors. Roller doors and high-speed
folding doors optimise the flow of traffic, improve the room climate and save
energy.
Hörmann roller doors and high-speed folding doors comply with strict European
safety requirements.
High-speed roller door V 3010
Technical data
| V 3010 | |
|---|---|
| Use | Internal door | 
| External door | |
| Door sizes | Maximum width LDB | 
| Maximum height LDH | |
| Minimum width (structural opening) | |
| Minimum height (structural opening) | |
| Speed | Control contactor, 400 V, 3-phase | 
| Security equipment | EN 13241 | 
| Wind load resistance | EN 12424 | 
| Thermal insulation | EN 13241-1, ISO 12567-1 | 
| without glazing, with Thermoframe | –– | 
| Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 | 
| Resistance to water penetration | EN 12425 | 
| Air permeability | EN 12426 | 
| Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, | 
EN ISO 10140-2
| ––
Door construction|  Self-supporting| ●
Material|  Galvanized| ●
 | Powder-coated| O
 | Stainless steel V2 A| O
Door leaf|  UPVC curtain                                     1,0 mm| ●
 | Steel pipe| ––
 | Fibreglass pipe| ●
 | Flexible side guide| ––
 | Side guide made of polyethylene| ●
Glazing|  Elongated windows| ––
 | Rectangular windows| O
Safety equipment|  Soft bottom edge| ––
 | Photocell SAFETIME double safety patent system| ●
Operator and control|  Inversion relay control / frequency converter
control|
 | Connecting voltage                             1-phase, 1 – 230 V, N, PE| O
 | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button| ●
 | AK E 370 M-I (inversion relay)| ●
 | AK E 370 M (inversion relay)| O
 | BK 370 M FUE-1 (frequency converter)| O
Emergency opening|  Emergency crank handle| ●
 | Emergency hand chain| ––
 | UPS in a plastic cabinet (220 V, 1-phase)| O
Suitable for temperatures from °C to °C|   | +5 °C to +40 °C
● = Standard                    O = Optional|  |  
The high-speed roller door for areas without draughts
- A Side guide in front of the opening
- B Side guide in the opening
- BPA Space required to fit and dismantle the operator
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door
- S Lintel height
High-speed folding doors
Technical data
| F 4010 Cold | |
|---|---|
| Use | Internal door | 
| External door | |
| Door sizes | Maximum width LDB | 
| Maximum height LDH | |
| Minimum width (structural opening) | |
| Minimum height (structural opening) | |
| Speed | Inversion relay, 400 V, 3-phase | 
| Security equipment | EN 13241 | 
| Wind load resistance | EN 12424 | 
| Thermal insulation | EN 13241-1, ISO 12567-1 | 
| without glazing, with Thermoframe | ● | 
| Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 | 
| Resistance to water penetration | EN 12425 | 
| Air permeability | EN 12426 | 
| Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, | 
EN ISO 10140-2
|  | ––
Door construction|  Self-supporting|  | ●
Material|  Galvanized|  | ––
 | Powder-coated|  | ●
 | Stainless steel V2 A|  | O
Door leaf|  UPVC curtain| 1,0 mm| ●
 | Spring steel pipe|  | ––
 | Fibreglass pipe|  | ●
 | Tension and safety belts|  | ●
 | Flexible guides|  | ●
 | Flexible guides in the side elements|  | ––
 | Side guide made of polyethylene|  | ––
 | Multi-layer ISO material| 3.0 mm| ●
Glazing|  Oval and rectangular windows|  | ––
 | Without window|  | ––
Safety equipment|  Light grille|  | ––
 | Soft bottom edge|  | ––
 | Photocells|  | ●
Operator and control|  Frequency converter control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| O
 | Inversion relay control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button|  | ●
 | AK E (inversion relay)|  | ●
 | AK 500 FUE-1 (frequency converter)|  | O
 | AK E 2500 M-I (inversion relay)|  | ––
 | AK E-700 M (inversion relay)|  | ––
 | AK E-750 M (inversion relay)|  | O
 | Electronic limit switch DES|  | ●
Emergency opening|  Emergency crank handle|  | ––
 | Emergency hand chain|  | ●  
● = Standard O = Optional
High-speed folding door F 4010 Cold
The insulated deep freeze door
- BPA Space required to fit and dismantle the operator
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door
High-speed folding doors
Technical data
● = Standard O = Optional 1) Optionally up to class 4 2) F 6010 ISO optionally from –30 °C up to +40 °C
Attention!
F 6010 ISO is not a cold door. The frames are not heated.
High-speed folding door F 6010 / F 6010 Iso
For fast door opening up to wind load class 4
- A Side guide in front of the opening
- B Side guide in the opening
- BPA Space required to fit and dismantle the operator
- LB Clear width
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door side element
High-speed folding door F 6010 / F 6010 Iso
For fast door opening up to wind load class 4
- BPA Space required to fit and dismantle the operator
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door
High-speed folding doors
Technical data
| F 8005 | |
|---|---|
| Use | Internal door | 
| External door | |
| Door sizes | Maximum width LDB | 
| Maximum height LDH | |
| Minimum width (structural opening) | |
| Minimum height (structural opening) | |
| Speed | Control contactor, 400 V, 3-phase | 
| Security equipment | EN 13241 | 
| Wind load resistance | EN 12424 | 
| Thermal insulation | EN 13241-1, ISO 12567-1 | 
| without glazing, with Thermoframe | –– | 
| Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 | 
| Resistance to water penetration | EN 12425 | 
| Air permeability | EN 12426 | 
| Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, | 
EN ISO 10140-2
|  | ––
Door construction|  Self-supporting|  | ––
Material|  Galvanized|  | ––
 | Powder-coated|  | ●
 | Stainless steel V2 A|  | O
Door leaf|  UPVC curtain| 1,0 mm| ●
 | Galvanized steel pipe|  | ●
 | Fibreglass pipe|  | ––
 | Tension and safety belts|  | ●
 | Flexible guides|  | ––
 | Flexible guides in the side elements|  | ●
 | Side guide made of polyethylene|  | ––
 | Multi-layer ISO material| 3.0 mm| ––
Glazing|  Oval windows|  | O
 | Without window|  | ●
Safety equipment|  Light grille|  | ––
 | Soft bottom edge|  | ––
 | Photocells|  | ●
Operator and control|  Frequency converter control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| ––
 | Inversion relay control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 230 V, N, PE| ●
 |  | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button|  | ●
 | AK E (inversion relay)|  | ––
 | AK 500 FUE-1 (frequency converter)|  | ––
 | AK E 2500 M-I (inversion relay)|  | ––
 | AK E-700 M (inversion relay)|  | ●
 | AK E-750 M (inversion relay)|  | ––
 | Electronic limit switch DES|  | ––
Emergency opening|  Emergency crank handle|  | ––
 | Emergency hand chain|  | ––  
● = Standard O = Optional
High-speed folding door F 8005
For large exterior door openings up to 8 m wide
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door side element
High-speed folding doors
Technical data
| F 14005 | |
|---|---|
| Use | Internal door | 
| External door | |
| Door sizes | Maximum width LDB | 
| Maximum height LDH | |
| Minimum width (structural opening) | |
| Minimum height (structural opening) | |
| Speed | Control contactor, 400 V, 3-phase | 
| Security equipment | EN 13241 | 
| Wind load resistance | EN 12424 | 
| Thermal insulation | EN 13241-1, ISO 12567-1 | 
| without glazing, with Thermoframe | –– | 
| Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 | 
| Resistance to water penetration | EN 12425 | 
| Air permeability | EN 12426 | 
| Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, | 
EN ISO 10140-2
|  | ––
Door construction|  Self-supporting|  | ––
Material|  Galvanized|  | ––
 | Powder-coated|  | ●
 | Stainless steel V2 A|  | O
Door leaf|  UPVC curtain| 1,0 mm| ●
 | Galvanized steel pipe|  | ––
 | Fibreglass pipe|  | ●
 | Tension and safety belts|  | ●
 | Flexible guides|  | ––
 | Flexible guides in the side elements|  | ––
 | Side guide made of polyethylene|  | ––
 | Multi-layer ISO material| 3.0 mm| ––
Glazing|  Oval windows|  | O
 | Without window|  | ●
Safety equipment|  Light grille|  | ––
 | Soft bottom edge|  | ●
 | Photocells|  | ●
Operator and control|  Frequency converter control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 400 V, N, PE| ––
 | Inversion relay control|  |
 | Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
 |  | 3-phase, 3 – 230 V, N, PE| ●
 |  | 3-phase, 3 – 400 V, N, PE| ●
 | Open-Stop-Close button|  | ●
 | AK E (inversion relay)|  | ––
 | AK 500 FUE-1 (frequency converter)|  | ––
 | AK E 2500 M-I (inversion relay)|  | ––
 | AK E-700 M (inversion relay)|  | ●
 | AK E-750 M (inversion relay)|  | ––
 | Electronic limit switch DES|  | ––
Emergency opening|  Emergency crank handle|  | ––
 | Emergency hand chain|  | ––  
● = Standard O = Optional
High-speed folding door F 14005
For large exterior door openings up to 14 m wide
- Max. 70 m²
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door side element
Hörmann: Quality without Compromise
Hörmann is the only manufacturer worldwide that offers you a complete range of
all major building products from one source.
We manufacture in highly-specialised factories using the latest production
technologies. The close-meshed network of sales and service companies
throughout Europe, and activities in the USA and Asia, make Hörmann your
strong partner for first-class building products, offering “Quality without
Compromise”.
GARAGE DOORS
OPERATORS
INDUSTRIAL DOORS
LOADING EQUIPMENT
HINGED DOORS
DOOR FRAMES
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>