Specifications:
- Door sizes: Internal and external
- Speed: Max. opening approx. m/s, Max. closing approx. m/s
- Security equipment: Glazing, Safety equipment
- Wind load resistance: EN 12424, EN 12425, EN 13241-1, ISO 12567-1
- Door leaf: Self-supporting, Galvanized, Powder-coated, Stainless steel V2 A
Product Usage Instructions
Door Installation:
- Measure the structural opening width and height for proper door fit.
- Install the side guides according to the space required for fitting and dismantling the operator.
- Position the lintel height to ensure smooth operation of the door.
Operating the Door:
- Use the Open-Stop-Close button for regular door operation.
- In case of emergency, use the provided Emergency crank handle or Emergency hand chain.
- Ensure that the UPS in a plastic cabinet is connected to maintain functionality during power outages.
Maintenance:
- Regularly inspect the door leaf, side guides, and safety equipment for any damage.
- Keep the glazing clean for optimal visibility.
- Lubricate moving parts as recommended by the manufacturer.
FAQ:
Q: What should I do if the door gets stuck during operation?
A: In case of a door malfunction, use the Emergency crank handle or
Emergency hand chain to manually open or close the door.
Q: Can I adjust the opening and closing speed of the door?
A: Yes, you can adjust the opening and closing speed using the control
panel provided with the door.
Roller doors and high-speed folding doors
NEW: The space-saving high-speed roller door V 3010 for areas without draughts
Fitting data
Issue 01.03.2021
Hörmann roller doors and high-speed folding doors A broad programme for inside and outside
From low-cost design models to secure night doors
Hörmann roller doors and high-speed folding doors are distinguished by high-
quality materials and secure long-term functionality. Roller doors and high-
speed folding doors are used indoors and outdoors. Roller doors and high-speed
folding doors optimise the flow of traffic, improve the room climate and save
energy.
Hörmann roller doors and high-speed folding doors comply with strict European
safety requirements.
High-speed roller door V 3010
Technical data
V 3010 | |
---|---|
Use | Internal door |
External door | |
Door sizes | Maximum width LDB |
Maximum height LDH | |
Minimum width (structural opening) | |
Minimum height (structural opening) | |
Speed | Control contactor, 400 V, 3-phase |
Security equipment | EN 13241 |
Wind load resistance | EN 12424 |
Thermal insulation | EN 13241-1, ISO 12567-1 |
without glazing, with Thermoframe | –– |
Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 |
Resistance to water penetration | EN 12425 |
Air permeability | EN 12426 |
Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, |
EN ISO 10140-2
| ––
Door construction| Self-supporting| ●
Material| Galvanized| ●
| Powder-coated| O
| Stainless steel V2 A| O
Door leaf| UPVC curtain 1,0 mm| ●
| Steel pipe| ––
| Fibreglass pipe| ●
| Flexible side guide| ––
| Side guide made of polyethylene| ●
Glazing| Elongated windows| ––
| Rectangular windows| O
Safety equipment| Soft bottom edge| ––
| Photocell SAFETIME double safety patent system| ●
Operator and control| Inversion relay control / frequency converter
control|
| Connecting voltage 1-phase, 1 – 230 V, N, PE| O
| 3-phase, 3 – 400 V, N, PE| ●
| Open-Stop-Close button| ●
| AK E 370 M-I (inversion relay)| ●
| AK E 370 M (inversion relay)| O
| BK 370 M FUE-1 (frequency converter)| O
Emergency opening| Emergency crank handle| ●
| Emergency hand chain| ––
| UPS in a plastic cabinet (220 V, 1-phase)| O
Suitable for temperatures from °C to °C| | +5 °C to +40 °C
● = Standard O = Optional| |
The high-speed roller door for areas without draughts
- A Side guide in front of the opening
- B Side guide in the opening
- BPA Space required to fit and dismantle the operator
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door
- S Lintel height
High-speed folding doors
Technical data
F 4010 Cold | |
---|---|
Use | Internal door |
External door | |
Door sizes | Maximum width LDB |
Maximum height LDH | |
Minimum width (structural opening) | |
Minimum height (structural opening) | |
Speed | Inversion relay, 400 V, 3-phase |
Security equipment | EN 13241 |
Wind load resistance | EN 12424 |
Thermal insulation | EN 13241-1, ISO 12567-1 |
without glazing, with Thermoframe | ● |
Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 |
Resistance to water penetration | EN 12425 |
Air permeability | EN 12426 |
Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, |
EN ISO 10140-2
| | ––
Door construction| Self-supporting| | ●
Material| Galvanized| | ––
| Powder-coated| | ●
| Stainless steel V2 A| | O
Door leaf| UPVC curtain| 1,0 mm| ●
| Spring steel pipe| | ––
| Fibreglass pipe| | ●
| Tension and safety belts| | ●
| Flexible guides| | ●
| Flexible guides in the side elements| | ––
| Side guide made of polyethylene| | ––
| Multi-layer ISO material| 3.0 mm| ●
Glazing| Oval and rectangular windows| | ––
| Without window| | ––
Safety equipment| Light grille| | ––
| Soft bottom edge| | ––
| Photocells| | ●
Operator and control| Frequency converter control| |
| Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
| | 3-phase, 3 – 400 V, N, PE| O
| Inversion relay control| |
| Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
| | 3-phase, 3 – 400 V, N, PE| ●
| Open-Stop-Close button| | ●
| AK E (inversion relay)| | ●
| AK 500 FUE-1 (frequency converter)| | O
| AK E 2500 M-I (inversion relay)| | ––
| AK E-700 M (inversion relay)| | ––
| AK E-750 M (inversion relay)| | O
| Electronic limit switch DES| | ●
Emergency opening| Emergency crank handle| | ––
| Emergency hand chain| | ●
● = Standard O = Optional
High-speed folding door F 4010 Cold
The insulated deep freeze door
- BPA Space required to fit and dismantle the operator
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door
High-speed folding doors
Technical data
● = Standard O = Optional 1) Optionally up to class 4 2) F 6010 ISO optionally from –30 °C up to +40 °C
Attention!
F 6010 ISO is not a cold door. The frames are not heated.
High-speed folding door F 6010 / F 6010 Iso
For fast door opening up to wind load class 4
- A Side guide in front of the opening
- B Side guide in the opening
- BPA Space required to fit and dismantle the operator
- LB Clear width
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door side element
High-speed folding door F 6010 / F 6010 Iso
For fast door opening up to wind load class 4
- BPA Space required to fit and dismantle the operator
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door
High-speed folding doors
Technical data
F 8005 | |
---|---|
Use | Internal door |
External door | |
Door sizes | Maximum width LDB |
Maximum height LDH | |
Minimum width (structural opening) | |
Minimum height (structural opening) | |
Speed | Control contactor, 400 V, 3-phase |
Security equipment | EN 13241 |
Wind load resistance | EN 12424 |
Thermal insulation | EN 13241-1, ISO 12567-1 |
without glazing, with Thermoframe | –– |
Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 |
Resistance to water penetration | EN 12425 |
Air permeability | EN 12426 |
Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, |
EN ISO 10140-2
| | ––
Door construction| Self-supporting| | ––
Material| Galvanized| | ––
| Powder-coated| | ●
| Stainless steel V2 A| | O
Door leaf| UPVC curtain| 1,0 mm| ●
| Galvanized steel pipe| | ●
| Fibreglass pipe| | ––
| Tension and safety belts| | ●
| Flexible guides| | ––
| Flexible guides in the side elements| | ●
| Side guide made of polyethylene| | ––
| Multi-layer ISO material| 3.0 mm| ––
Glazing| Oval windows| | O
| Without window| | ●
Safety equipment| Light grille| | ––
| Soft bottom edge| | ––
| Photocells| | ●
Operator and control| Frequency converter control| |
| Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
| | 3-phase, 3 – 400 V, N, PE| ––
| Inversion relay control| |
| Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
| | 3-phase, 3 – 230 V, N, PE| ●
| | 3-phase, 3 – 400 V, N, PE| ●
| Open-Stop-Close button| | ●
| AK E (inversion relay)| | ––
| AK 500 FUE-1 (frequency converter)| | ––
| AK E 2500 M-I (inversion relay)| | ––
| AK E-700 M (inversion relay)| | ●
| AK E-750 M (inversion relay)| | ––
| Electronic limit switch DES| | ––
Emergency opening| Emergency crank handle| | ––
| Emergency hand chain| | ––
● = Standard O = Optional
High-speed folding door F 8005
For large exterior door openings up to 8 m wide
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door side element
High-speed folding doors
Technical data
F 14005 | |
---|---|
Use | Internal door |
External door | |
Door sizes | Maximum width LDB |
Maximum height LDH | |
Minimum width (structural opening) | |
Minimum height (structural opening) | |
Speed | Control contactor, 400 V, 3-phase |
Security equipment | EN 13241 |
Wind load resistance | EN 12424 |
Thermal insulation | EN 13241-1, ISO 12567-1 |
without glazing, with Thermoframe | –– |
Thermal insulation value in W/(m²·K) | EN 13241-1, ISO 12567-1 |
Resistance to water penetration | EN 12425 |
Air permeability | EN 12426 |
Acoustic insulation | EN ISO 717-1, EN ISO 10140-1, |
EN ISO 10140-2
| | ––
Door construction| Self-supporting| | ––
Material| Galvanized| | ––
| Powder-coated| | ●
| Stainless steel V2 A| | O
Door leaf| UPVC curtain| 1,0 mm| ●
| Galvanized steel pipe| | ––
| Fibreglass pipe| | ●
| Tension and safety belts| | ●
| Flexible guides| | ––
| Flexible guides in the side elements| | ––
| Side guide made of polyethylene| | ––
| Multi-layer ISO material| 3.0 mm| ––
Glazing| Oval windows| | O
| Without window| | ●
Safety equipment| Light grille| | ––
| Soft bottom edge| | ●
| Photocells| | ●
Operator and control| Frequency converter control| |
| Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
| | 3-phase, 3 – 400 V, N, PE| ––
| Inversion relay control| |
| Connecting voltage| 1-phase, 1 – 230 V, N, PE| ––
| | 3-phase, 3 – 230 V, N, PE| ●
| | 3-phase, 3 – 400 V, N, PE| ●
| Open-Stop-Close button| | ●
| AK E (inversion relay)| | ––
| AK 500 FUE-1 (frequency converter)| | ––
| AK E 2500 M-I (inversion relay)| | ––
| AK E-700 M (inversion relay)| | ●
| AK E-750 M (inversion relay)| | ––
| Electronic limit switch DES| | ––
Emergency opening| Emergency crank handle| | ––
| Emergency hand chain| | ––
● = Standard O = Optional
High-speed folding door F 14005
For large exterior door openings up to 14 m wide
- Max. 70 m²
- LDB Clear passage width
- LDH Clear passage height
- MFR Space for fitting the door side element
Hörmann: Quality without Compromise
Hörmann is the only manufacturer worldwide that offers you a complete range of
all major building products from one source.
We manufacture in highly-specialised factories using the latest production
technologies. The close-meshed network of sales and service companies
throughout Europe, and activities in the USA and Asia, make Hörmann your
strong partner for first-class building products, offering “Quality without
Compromise”.
GARAGE DOORS
OPERATORS
INDUSTRIAL DOORS
LOADING EQUIPMENT
HINGED DOORS
DOOR FRAMES
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>