beurer LB 37 Air Humidifier Instruction Manual
- June 5, 2024
- Beurer
Table of Contents
- **beurer LB 37 Air Humidifier
- Included in delivery
- Electric shock
- Risk of fire
- **Device description
- Principle behind the LB 37 air humidifier
- Cleaning and maintenance
- Cleaning the ultrasound membrane with a brush, rinsing the base
- Accessories and replacement parts
- Replacement items
- Technical specifications
- Warranty / Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**beurer LB 37 Air Humidifier
**
Read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
WARNING
- This device may be used by children over the age of eight and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
- Children must not play with the device.
- Cleaning and user maintenance must not be performed by children unless supervised.
- Disconnect the device from the mains supply during filling or cleaning.
- Do not use any solvent-based cleaning products.
- If the mains connection cable of this device is damaged, it must be dis-posed of. If it cannot be removed, the device must be disposed of.
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Do not permit the area around the device to become damp or wet. If dampness occurs, turn the output of the device down. If the output vo-lume cannot be turned down, use the device intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the device before storage. Clean the device before next use.
- Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank is not cleaned properly every three days.
Dear Customer
Thank you for choosing a product from our range. Our name stands for high-
quality, thoroughly tested products for applications in the areas of heat,
weight, blood pressure, body temperature, pulse, gentle therapy, massage,
beauty, air and baby.
With kind regards,Your Beurer team
Getting to know your device
Humans spend a large proportion of their time indoors.
For ideal ambient air, a humidity level of between 40 % and 60 % is
recommended. This value is often not reached, particularly in winter, when
cold, dry air enters living spaces that are being aired and is then warmed up.
This dry ambient air draws in moisture, drying out mucous membranes and skin,
but also furniture. Ambient air that is too dry may have a number of negative
effects.
- Mucous membranes and lips dry out.
- Eyes become irritated.
- Infections and respiratory diseases are more likely to occur.
- Exhaustion, tiredness and difficulty concentrating.
- Pets and plants are put under unnecessary strain.
- Dust forms more quickly.
- Electrostatic charging of textiles made of synthetic fibres, such as carpets and plastic floor coverings.
- Wooden furniture and, especially, parquet floors, are damaged.
- Musical instruments go out of tune.
Included in delivery
- Base unit for air humidifier
- Water tank for air humidifier
- Cleaning brush
- Instructions for use
- 15 Aroma pads
Signs and symbols
The following symbols appear in these instructions for use:
-
WARNING
Warning instruction indicating a risk of injury or damage to health -
IMPORTANT
Safety note indicating possible damage to the device/accessory -
Product information
Note on important information -
Read the instructions
Disposal in accordance with the Waste Elec-trical and Electronic Equipment EC Directive – WEEE -
Manufacturer
-
CE labelling
-
This product satisfies the requirements of the applicable European and national directives.
-
Marking to identify the packaging mate-rial.
A = Material code, B = Material number: 1-7 = Plastics, 20-22 = Paper and card-board -
The products demonstrably meet the requirements of the Technical Regulations of the EAEU.
-
United Kingdom Conformity Assessed Mark
-
Separate the product and packaging elements and dispose of them in accordance with local regulations.
-
water tank, periodical cleaning
-
Separate the packaging elements and dispose of them in accordance with local regulations.
Warnings and safety notes
Read these instructions for use carefully. Non-observance of the following information may result in personal injury or material damage. Store these instructions for use and make them accessible to all users. Make sure to include these instructions for use when handing over the device to third parties.
Electric shock
WARNING
As with every electrical device, use this air humidifier carefully and cautiously, in order to avoid hazards due to electric shock.
- Only operate the device at the voltage indicated on the device (the type plate is located on the underside of the base unit).
- Only insert the mains cable into the socket when the device is switched off.
- Never use the device if it or its accessories are visibly damaged.
- Do not use the device if it has sustained a fall or if water has penetrated the device interior.
- Do not use the device during a storm.
- In the event of defects or operational faults, switch off the device immediately and disconnect the device from the mains socket.
- Do not pull on the mains cable or on the device to disconnect the plug from the socket.
- Never hold or carry the device by the mains cable.
- Do not clamp or pinch the mains cable.
- Keep the mains cable away from hot surfaces.
- Ensure that the mains cable and plug do not come into contact with water, steam or other liquids.
- Only use the device in dry internal rooms (e.g. never in the bathroom, sauna, etc.).
- Never reach for a device that has been submerged in water. Pull the plug out of the mains socket immediately.
- Do not subject the device to any impacts or drop the device.
Repairs
WARNING
- Do not open the base unit.
- Only specialist personnel may perform repairs on electrical devices. Improper repairs may subject users to considerable danger. For repairs, please contact customer service or an authorised retailer.
- If the mains cable of the device is damaged, it must be replaced by the manufacturer or an authorised customer service point.
Risk of fire
WARNING
There is a risk of fire if the device is used improperly or these instructions
for use are ignored.
- Never use the device underneath a cover, such as a blanket or pillow.
- Never use the device near highly flammable substances.
Operation
WARNING
- The device is only intended for the purpose described in these instructions for use. The manufacturer is not liable for damage resulting from improper or careless use.
- This device is not intended for use by people (including children) with restricted physical, sensory or mental skills or a lack of experience and/or a lack of knowledge, unless they are supervised by a person who has responsibility for their safety or instructed by him in how to use the device.
- Children should be supervised around the device to ensure they do not play with it.
- If you suffer from a severe respiratory or lung disease, consult your doctor before using the air humidifier.
- The device must be switched off after every use and before cleaning. Pull the plug out of the mains socket.
- Ensure that the mains cable does not pose a trip hazard.
IMPORTANT
- Ensure that the device is placed on a firm, flat surface that is not susceptible to moisture.
- Do not insert any objects into openings on the device. Ensure that the moving parts can move freely at all times.
- Do not place any objects on the device.
- Do not expose the device to high temperatures.
- Avoid direct sunlight.
Intended use
This air humidifier is designed for the humidification of ambient air. The device is intended for private use.
**Device description
**
The air humidifier
- humidifies the air,
- quiet operation,
- is suitable for rooms up to 20 m² in size,
- has a low energy consumption and switches off automatically when the water tank is empty,
- is easy to clean,
- features a night mode.
- Mist outlet
- Water tank
- Water tank screwed plug
- Water basin
- Base unit for air humidifier
- Ultrasound membrane
- ON/OFF button with LED display
- Aroma compartment
Principle behind the LB 37 air humidifier
- High-frequency vibrations release tiny drops from the surface of the water.
- The fan draws in air through the aroma compartment on the side of the device.
- Water evaporation can also be switched on.
- If you wish, the device can be used with aromas.
Initial use
Unpacking the device
WARNING
Keep packaging material away from children! There is a choking hazard.
- Open the cardboard packaging.
- Remove the protective insert.
- Keep the plastic film closed.
- Lift the device up and out of the packaging.
- Remove the plastic covering.
- Check the device, the mains plug and the cable for damage.
Installation location
WARNING
Before putting the device into operation, read the safety notes in the Safety
chapter.
- The immediate vicinity of the air humidifier can become damp.
- Calcareous water can leave white deposits.
- Do not place the device on the floor, but in a raised position (e.g. on a table or chest of drawers).
- Position the device so that the mist outlet is not directed towards objects.
- Empty any remaining water when the device is not in use.
- Place the air humidifier on a firm, level and water-resistant surface.
If the device should accidentally tip over, water may escape, even if the device is switched off and unplugged.
Water
Note
- Do not add any essential oils or fragrances to the water. If additives are used, the plastic material may become discoloured and damaged. The ultrasound membrane gets stuck and is damaged.
- Use fresh drinking water below 40°C in the device. If the drinking water is very hard, you can use demi-neralised or distilled water.
- Tip! If the water is hard, we recommend using the optional anti-limescale filter.
Filling the water tank
-
Lift the water tank and rotate it.
The water tank is kept closed by means of a spring valve. -
Open the screwed plug on the water tank.
-
Fill with water.
The water tank holds a maximum of 2 litres. -
Tightly close the water tank using the screwed plug.
-
Rotate the water tank and position it on the base unit. The tank should sit tightly on the base unit.
Usage
Note
Check the humidity of your ambient air regularly. Intensive continuous
operation can cause the ambient air to become excessively humid. The relative
air humidity should not exceed 60 %.
Switching on the device
- Insert the plug into the mains socket.
- If there is no or not enough water in the water tank, a red LED lights up. The device has switched off for safety reasons.
- Fill the water tank as described under 6. Initial use.
Hinweis
The device has three different modes:
| LED lighting| Air humidifiers| Evaporation output
---|---|---|---
Press the ON/OFF button ( ) 1x| blue| Level 1| ~ 200 ml/h
Press the ON/OFF button ( ) 2x| white| Level 2| ~ 150 ml/h
Press the ON/OFF button ( ) 3x (Night mode)| OFF| Level 2| ~ 150 ml/h
Press the ON/OFF button ( ) 4x| OFF| OFF| –
Note
You may optionally add drops of aroma/scented oils to the aroma compartment
(8). These will lend a pleasant odour to the room. Under no circumstances
should you add the aroma directly to the water.
Switching off the device
- Press the ON/OFF button ( ) 4 times. The LED lighting goes off.
- Pull the plug out of the mains socket.
Note
In night mode, the air humidifier operates in level 2 with a lower evaporation output and no LED illumination to ensure undisturbed and therefore restful sleep.
Cleaning and maintenance
Regular cleaning and disinfection are a prerequisite for hygienic and fault-
free operation.
The level of contamination of the device depends on the water quality and how
long it has been in operation. In any case, we recommend the following
cleaning intervals.
Every three days| As required|
---|---|---
x| | Clean the ultrasound membrane with a brush, rinse the base.
x| | Rinse the water tank, replace the water.
x| | Clean the air humidifier inside and out.
| x| Descale.
Use either a citric acid solution (30 g pure citric acid powder dissolved in 1
l water) or a vinegar solution (household vinegar with 5% acid content mixed
with water in a ratio of 1:2) as a descaling solution.
WARNING
The device must be switched off after every use and before cleaning. Pull the
plug out of the mains socket.
IMPORTANT
The water tank must be cleaned and the air humidifier completely emptied if the device has not been used for 72 hours.
Note
- Clean the device using only the methods specified.
- Under no circumstances may liquid enter the base unit.
- Do not use any solvent-based cleaning products.
- Use only a mild detergent or citric acid or vinegar-based solution to perform cleaning or disinfection work.
Cleaning the ultrasound membrane with a brush, rinsing the base
Note
Empty the water from the base unit via the side rim in the direction
indicated by the arrow. Ensure that no water gets inside the device, e.g. via
the fan opening.
- Clean the ultrasound membrane using the cleaning brush provided.
- Empty the water from the base unit via the side edge.
- Should dirty residue remain in the base unit, pour some clean, fresh water into the base unit and empty it out via the side edge.
Rinsing the water tank, replacing the water
- Clean the water tank regularly, at least every three days if using daily.
- Use a mild cleaning product or a citric acid or vinegar-based solution.
- Clean the thread of the screwed plug using a soft brush.
- Half-fill the water tank with water.
- Tightly close the water tank using the screwed plug.
- Shake the water tank by rocking it back and forth several times.
- Empty out the water completely.
- Repeat the process using clean, fresh water.
Cleaning the air humidifier inside and out
- Empty the water from the base unit via the side edge.
- Wipe the air humidifier with a damp cloth inside and out. Use only a mild detergent or citric acid or vinegar-based solution to perform cleaning work.
Descaling
Descaling the ultrasound membrane
Hard water can cause limescale to build up in the device and, especially, on
the ultrasound membrane. This forms white deposits. Descale the device
regularly.
- Drop some descaling solution onto the ultrasound membrane.
- Leave it to take effect for two to five minutes.
- Clean the ultrasound membrane using the cleaning brush.
- Rinse the base unit twice with clean, freshwater.
Cleaning inside the base unit
- Dip a damp, soft cloth briefly in the descaling solution.
- Use the cloth to wipe the inside of the base unit.
- Carefully pour some clean, freshwater into the base unit.
- Empty the water from the base unit via the side edge.
- Repeat the process using clean, freshwater.
Descaling the water tank
- Half-fill the water tank with a descaling solution.
- Tightly close the water tank using the screwed plug.
- Shake the water tank by rocking it back and forth several times.
- Empty the descaling solution completely.
- Repeat the process twice using clean, freshwater.
Accessories and replacement parts
Tip!
If the water is hard, we recommend using the optional anti-limescale filter.
Anti-limescale filter (optional).
Note
- If the anti-limescale filter does not prevent limescale build-up, or if white deposits form on or in the device, the anti-limescale filter should be replaced.
- The service life of the anti-limescale filter is around two to three months at most.
- If the device is not used for a relatively long time, the anti-limescale filter must be removed from the water tank and dried out.
Fitting the anti-limescale filter
- Lift the water tank and rotate it.
- Open the screwed plug on the water tank.
- Screw the anti-limescale filter onto the screwed plug on the inside.
- Tightly close the water tank using the screwed plug.
Replacement items
For replacement parts and additional items visit
www.beurer.com or contact the corresponding service
address in your country (according to the service address list).
Replacement parts and additional items are also available from retailers.
Item | Item number |
---|---|
Beurer by Taoasis “Vitality” aroma oil (10 ml) | 681.30 |
Beurer by Taoasis “Harmony” aroma oil (10 ml) | 681.31 |
Beurer by Taoasis “Relax” aroma oil (10 ml) | 681.32 |
Beurer by Taoasis “Sleep Well” aroma oil (10 ml) | 681.33 |
10 aroma pads | 163.801 |
Anti-limescale filter (optional) | 163.803 |
What if there are problems?
Problem | Cause | Solution |
---|---|---|
No LED display | The mains cable is not plugged in. | Connect the plug. |
Red LED | The water level is too low; the wa- ter tank is empty. | Fill the |
water tank.
No mist is produced| The LED display lights red .| Fill the water tank.
The LED display does not light up.
The mist has a strange smell| The device is new.| Remove the water tank, turn
the screwed plug and remove it.
Air the open, emply water tank in a cool, dry place for twelve hours.
Stale or dirty water.| Empty the base unit and the water tank and clean them thoroughly.
Fill the water tank with fresh water.
Strange noise| The water tank is not positioned correctly on the base unit.| Lift up the water tank and position it correctly on the base unit.
The tank should sit tightly on the base unit.
There is too little water in the water tank.| Fill the water tank.
The device is not level and unsta- ble.| Place the device on a firm, level
surface.
Problem | Cause | Solution |
---|---|---|
Mist escapes underneath the water tank | The water tank is not positioned | |
correctly on the base unit. | Lift up the water tank. |
Check whether the join between the base unit and water tank is clean.
Clean if required.
Position the water tank correctly on the base unit. The tank should sit tightly on the base unit.
The LED lights up red although the tank is full| The device evaluates the water level incorrectly due to a fault.| Restart the device.
Technical specifications
Dimensions (LxWxH) | approx. 21 cm x 11 cm x 25,5 cm |
---|---|
Cable length | approx. 1.5 m |
Mains voltage/frequency | 100 – 240 V AC / 50/60 Hz |
Nominal power | max. 20 W |
Room size | up to 20 m² |
Capacity | approx. 2 litres |
Evaporation output | 200 ml/hour |
Signs and symbols | The unit is double-protected and thus corresponds to |
protection class 2.
Volume| approx. 35 dB
Disposal
For environmental reasons, do not dispose of the device in the household waste
at the end of its useful life. Dispose of the unit at a suitable local
collection or recycling point. Dispose of the device in accordance with EC
Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any
questions, please contact the local authorities responsible for waste
disposal.
Warranty / Service
Further information on the warranty and warranty conditions can be found in the warranty leaflet supplied.
References
- Beurer — Beurer North America
- Beurer Gesundheitsratgeber
- Beurer Health Guide
- Beurer GmbH | Health and wellbeing
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>