BEGA 51 262.4 Wall Luminaire for Indoor Instruction Manual

August 22, 2024
BEGA

BEGA 51 262.4 Wall Luminaire for Indoor

Dimension

Application

  • Wall luminaire · indoor luminaire with light emission on two sides for the glare free illumination of wall surfaces with the mounting surface being the reflection surface.
  • A luminaire which allows interesting illumination concepts individually or in rows.

Product Description

  • Luminaire housing made of aluminium, finish Colour velvet brass
  • Silicone light diffuser
  • 3 elongated fixing holes
  • Width 4.5 mm · 540 mm spacing
  • Mounting plate with several openings for cable entry and through-wiring for mains cable
  • Connecting terminals 2.5
  • Earth conductor connection
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 2
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule
  • CE – Conformity mark
  • Weight: 4.5 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Specifications

Lamp

  • Module connected wattage 42.4 W
  • Luminaire connected wattage 50 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

51 262.4 K3

  • Module designation 2x LED-1320/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 6600 lm
  • Luminaire luminous flux 3067 lm
  • Luminaire luminous efficiency 61,3 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Undo the hexagon socket head screws (wrench size 3 mm) and lift luminaire housing.
  • Loosen earth connection (plug connection) between luminaire housing and mounting plate.
  • Pass the power connecting cable through one of the openings of the mounting plate.
  • Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
  • Make the electrical connection to the terminals.
  • Please ensure correct wire assignment for the connecting cable.
  • Connect the earth conductor to the green-yellow wire ( ). Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
  • Use the terminals marked DA, DA for digital control.
  • If these terminals are not used, the luminaire will operate at full light output.
  • Make earth connection (plug connection) between luminaire housing and mounting plate again.
  • Hang the luminaire housing in the mounting plate and screw it in place with the hexagon socket head screws.

Maintenance

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system from the power supply.
  • Press the synthetic LED cover together lengthwise and remove it from the housing profile.
  • Remove the LED module. Install the replacement LED module.
  • Please follow the installation instructions for the LED module.
  • A defective LED cover must be replaced.

Spares

  • LED power supply unit DEV-0388/700i
  • LED module 3000 K with diffusor LED-1320/930

FAQ

  • What are the recommended ambient temperatures for this luminaire?
    • The recommended ambient temperature range for this luminaire is between 25°C to 45°C.
  • Where can I find spares for this product?
    • The spares for this product include DEV-0388/700i LED power supply unit and LED-1320/930 LED module 3000 K with diffuser.

Contact

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals