MEAN WELL DDR-240 series Rail Power Supplies Owner’s Manual
- August 22, 2024
- MEAN WELL
Table of Contents
MEAN WELL DDR-240 series Rail Power Supplies
Specifications
Model | Output Voltage | Input Voltage | Rated Wattage |
---|---|---|---|
DDR-240B-24 | 24V | B: 16.8~33.6Vdc | 240W |
DDR-240B-48 | 48V | C: 33.6~67.2Vdc | 240W |
DDR-240C-24 | 24V | D: 67.2~154Vdc | 240W |
DDR-240C-48 | 48V | ||
DDR-240D-24 | 24V | ||
DDR-240D-48 | 48V |
Product Usage Instructions
Installation
- Ensure the power source matches the input voltage range of the converter.
- Mount the converter on a DIN rail TS-35/7.5 or 15 securely.
- Connect the input and output terminals following the polarity markings.
- Ensure proper ventilation for cooling by free air convection.
Operation
- Power on the converter within the specified temperature range of -40°C to +70°C.
- Use the DC output adjustable feature to set the desired output voltage.
- Monitor the status of the converter using the provided protections for short circuits, overload, over-voltage, over-temperature, input reverse polarity, and input under voltage protection.
- Utilize the DC OK relay contact and remote ON-OFF control as needed.
Maintenance
- Regularly check for any signs of damage or overheating.
- Clean the unit as necessary to prevent dust accumulation.
- Refer to the user manual for troubleshooting steps in case of any issues.
FAQ
- Q: What is the peak load capability of the DDR-240 series?
- A: The DDR-240 series has a peak load capability of 150%.
- Q: What applications are suitable for the DDR-240 series?
- A: The DDR-240 series is suitable for use in bus, tram, metro or railway systems, industrial control systems, semiconductor fabrication equipment, factory automation, electro-mechanical applications, wireless networks, and telecom or datacom systems.
- Q: What is the warranty period for the DDR-240 series?
- A: The DDR-240 series comes with a 3-year warranty.
Features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- Width only 40mm
- 2:1 wide input range
- -40~+70°C wide working temperature
- 150% peak load capability
- Current sharing up to 960W(3+1)
- DC output adjustable
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Protections: Short circuit / Overload / Over voltage / Over temperature / Input reverse polarity/ Input under voltage protection
- 4KVdc 1/0 isolation(Reinforced isolation)
- DC OK relay contact
- Remote ON-OFF control
- 3 years warranty
Applications
- Bus, tram,metro or railway system
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical
- Wireless network
- Telecom or datacom system
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
- DDR-240 series is a 240W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra-slim width (40mm), 2:1 wide input voltage, fanless design, -40~+70°C wide operating temperature, 4KVdc 1/0 isolation, 150% peak load, current sharing, DC OK, adjustable output voltage and full protective functions.
- This series of models has various input options: 16.8~33.6V / 33.6~67.2V / 67.2~154V and two output options: 24V / 48V and can be used for industrial & railway control, security control, communication systems and other fields.
- Suitable applications include to DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable…etc.
Model Encoding
SPECIFICATION
MODEL| DDR-240B-24| DDR-240B-48| DDR-240C-24| DDR-
240C-48| DDR-240D-24| DDR-240D-48
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 24V| 48V| 24V| 48V| 24V| 48v
RATED CURRENT| 10A| 5A| 10A| 5A| 10A| 5A
CURRENT RANGE| 0 ~ 10A| 0 ~ 5A| 0 ~ 10A| 0 ~ 5A| 0 ~ 10A| 0 ~ 5A
RATED POWER| 240W| 240W| 240W| 240W| 240W| 240W
PEAK| CURRENT| 15A| 7.5A| 15A| 7.5A| 15A| 7.5A
POWER **Note.5| 360W (3sec.)
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 100mVp-p| 80mVp-p| 100mVp-p|
80mVp-p| 100mVp-p
VOLTAGE ADJ. RANGE| 24 ~ 28V| 48 ~ 56V| 24 ~ 28V| 48 ~ 56V| 24 ~ 28V|
48~ 56V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 60ms
HOLD UP TIME (Typ.)| Please refer to page 6 Hold up Time( Load de-rating
curve )
INPUT
| VOLTAGE RANGE Note.4| CONTINUOUS| 16.8 ~ 33.6Vdc| 33.6 ~
67.2Vdc| 67.2 ~ 154Vdc
100ms| 14.4 ~ 16.8Vdc| 28.8 ~33.6Vdc| 66 ~ 67.2Vdc
EFFICIENCY (Typ.)| 90%| 90%| 91%| 92%| 92%| 92.5%
DC CURRENT (Typ.)| 11.2A @24Vdc| 5.6A @48Vdc| 2.5A @110Vdc
INRUSH CURRENT (Typ.)| 30A
INTERRUPTION OF VOLTAGE SUPPLY
| EN50155:2007-B/C- type comply with S2 level (10ms)@ 70% load ; D-type
comply with S2 level (10ms)@ full load
EN50155:2017-Comply with S1 level
PROTECTION
| ****
OVERLOAD **Note.5**
| Normally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto- recovery
OVERVOLTAGE
| 28.8 ~ 35V| 57.6 ~ 65.0V| 28.8 ~ 35V| 57.6 ~ 65V| 28.8 ~ 35V| 57.6 ~ 65V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down the o/p voltage, and re-power on to recover
UNDER VOLTAGE LOCKOUT
| 24Vin (B – type) : Power ON≥16.8V,
OFF≤16.5V
| 48Vin (C – type) : Power ON≥33.6V,
OFF≤33V
| 110Vin (D – type): Power ON≥67.2V,
OFF≤65V
FUNCTION
| DC OK REALY CONTACT RATINGS (max.)| 30Vdc/1A
resistive load
CURRENT SHARING| Up to 960W (3+1 units). Please refer to the Function
Manual
REMOTE ON-OFF CONTROL| Please refer to the Function Manual
ENVIRONMENT
| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 5 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85, 5 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 55℃)
VIBRATION| Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X,
Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDE Note.7| 5000 meters
SAFETY & EMC
(Note 6)
| SAFETY STANDARDS| IEC 62368-1, UL 62368-1, EAC TP TC 004, AS/NZS
62368.1 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:0.71KVdc
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class B
Radiated| BS EN/EN55032| Class B
Voltage Flicker| BS EN/EN61000-3-3| —–
Harmonic Current| —–| —–
EMC IMMUNITY
| BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 3, 6KV contact; criteria A
Radiated| BS EN/EN61000-4-3| Level 3, 10V/m ; criteria A
EFT / Burst| BS EN/EN61000-4-4| Level 3, 2KV ; criteria A
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG
;criteria A
Conducted| BS EN/EN61000-4-6| Level 3, 10V ; criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m ; criteria A
RAILWAY STANDARD| Compliance to BS EN/EN45545-2 for fire protection
; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS
EN/EN50121-3-2 for EMC
OTHERS
| MTBF| 1415.6K hrs min. Telcordia SR-332 (Bellcore); 189.9K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 40125.2113.5mm (WHD)
PACKING| 0.76Kg;20psc/16.2Kg/1.16CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at normal input (B:24Vdc, C:48Vdc, D:110Vdc ), rated load, and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. 3 seconds max., please refer to peak loading curves.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than2000m(6500ft).
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Output derating VS input voltage
Peak Loading
DC OK Relay Contact
Contact Close | PSU turns on / DC OK. |
---|---|
Contact Open | PSU turns off / DC fails. |
Contact Ratings (max.) | 30V/1A resistive load. |
Function Manual
Current sharing
- Parallel operation is available by connecting the units shown as below (P+, P- are connected mutually in parallel) :
- The voltage difference among each output should be minimized that less than 0.2V is required.
- The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9.
- In parallel operation 4 units is the maximum, please consult the manufacturer for other applications.
- When in parallel operation, the minimum output load should be greater than 3% of the total output load.
(Min. load > 3% rated current per unit x number of unit)
Remote ON-OFF Control
The power supply can be turned ON-OFF by using the “Remote ON-OFF” function.
Remote ON-OFF (TB1 PIN2,4)|
Output Status
---|---
Open or 4 ~ 10VDC| power supply ON
Short or 0 ~ 0.8VDC| power supply OFF
Input Fuse
There is one fuse connected in series to the positive input line, which is
used to protect against abnormal surges. The fuse specifications of each model
are shown as below.
Type | Fuse Type | Reference and Rating |
---|---|---|
B | Time-Lag | Conquer MST, 10A, 250V *2 |
C | Time-Lag | Conquer MST, 6.3A, 250V *2 |
D | Time-Lag | Conquer MST, 6.3A, 250V *1 |
Input Under-Voltage Protection
- If the input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage.
- It recovers automatically when the input voltage reaches above Vimin, please refer to the curve below.
Input Reverse Polarity Protection
- There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.
Inrush Current
- Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up.
Hold-up Time
- EN50155: 2007 version – B/C- type complies with S2 level (10ms)@ 70% load; D-type complies with S2 level (10ms)@ full load, Please refer to the table and curves shown below for the hold-up time specification.
Load
Model
| 100% load| 70% load| another load
---|---|---|---
B type (24Vin)| 6ms min.| 10ms min.| figure 1,2
C type (48Vin)| 8ms min.| 11ms min.| figure 3,4
D type (110Vin)| 11ms min.| 15ms min.| figure 5,6
- EN50155: 2017 version – Comply with S1 level
Efficiency vs Load & Vin Curve
- The efficiency vs load & Vin curves of each model are shown as below.
Immunity to Environmental Conditions
Test method | Standard | Test conditions | Status |
---|---|---|---|
Cooling Test | EN 50155 section 12.2.3 (Column 2, Class TX) |
EN 60068-2-1
| Temperature: -40℃
Dwell Time: 2 hrs/cycle
| No damage
Dry Heat Test
| EN 50155 section 12.2.4 (Column 2, Class TX)
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2
|
Temperature: 70℃ / 85℃ Duration: 6 hrs / 10min
|
PASS
Damp Heat Test, Cyclic
|
EN 50155 section 12.2.5
EN 60068-2-30
| Temperature: 25℃~55℃ Humidity: 90%~100% RH Duration: 48 hrs|
PASS
Vibration Test
| EN 50155 section 12.2.11
EN 61373
| Temperature: 19℃ Humidity: 65%
Duration: 10 mins
|
PASS
Increased Vibration Test
|
EN 50155 section 12.2.11
EN 61373
| Temperature: 19℃ Humidity: 65%
Duration: 5 hrs
|
PASS
Shock Test
|
EN 50155 section 12.2.11
EN 61373
| Temperature: 21± 3℃ Humidity: 65 ± 5%
Duration: 30ms*18
|
PASS
Low-Temperature Storage Test
|
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
|
Temperature: -40℃ Dwell Time: 16 hrs
|
PASS
Salt Mist Test
|
EN 50155 section 12.2.10 (Class ST4)
|
Temperature: 35℃±2℃ Duration: 96 hrs
|
PASS
EN45545-2 Fire Test Conditions
Test Items | Hazard Level | ||
---|---|---|---|
Items | Standard |
HL1
|
HL2
|
HL3
|
Oxygen index test
| EN 45545-2:2013
EN ISO 4589-2:1996
|
PASS
|
PASS
|
PASS
R22
|
Smoke density test
| EN 45545-2:2013
EN ISO 5659-2:2006
|
PASS
|
PASS
|
PASS
|
Smoke toxicity test
| EN 45545-2:2013 NF X70-100:2006|
PASS
|
PASS
|
PASS
R24
|
Oxygen index test
| EN 45545-2:2013
EN ISO 4589-2:1996
|
PASS
|
PASS
|
PASS
R25
|
Glow-wire test
| EN 45545-2:2013
EN 60695-2-11:2000
|
PASS
|
PASS
|
PASS
R26
|
Vertical flame test
| EN 45545-2:2013
EN 60695-11:2003
|
PASS
|
PASS
|
PASS
Mechanical Specification
Installation Instruction
- This series fits DIN rail TS35/7.5 or TS35/15.
- For installation details, please refer to the Instruction manual.
Installation Manual
- Please refer to: http://www.meanwell.com/manual.html