BITMAIN T19 Pro Hyd BTC Miner Instruction Manual
- September 24, 2024
- BITMAIN
Table of Contents
T19 Pro Hyd BTC Miner
“`html
Specifications
Model| Version| Crypto algorithm/coins| Typical Hashrate, TH/s| Power on wall
@35, Watt| Power efficiency on wall@35, J/TH
---|---|---|---|---|---
T19 Pro Hyd.| k0-10| SHA256|BTC/BCH/BSV| 246| 5412| 22.0
Detailed Characteristics
-
Power supply:
- Phase: 3
- Input voltage, Volt: 380~415
- Input frequency range, Hz: 50~60
- Input max current, Amp: 12
-
Hardware configuration:
-
Network connection mode: RJ45 Ethernet 10/100M
-
Server size (LengthWidthHeight, w/o package), mm:
410170209 -
Server size (LengthWidthHeight, with package), mm:
570316430 -
Net weight, kg: 12.8
-
Gross weight, kg: 14.1
-
-
Environment requirements:
- Coolant flow, L/min: 8.0~10.0
- Coolant pressure, bar: 3.5
- Working coolant: Antifreeze/ Pure water/Deionized water
- Coolant pH value:
- Antifreeze: 7.0~9.0
- Pure water: 6.5~7.5
- Deionized water: 8.5~9.5
- Diameter of coolant pipe connector, mm: OD10
- Operation temperature: -20~70°C
- Operation humidity(non-condensing), RH: 10~90%
Product Usage Instructions
To effectively operate the T19 Pro Hyd., follow these steps:
-
Ensure the power supply phase is set to 3 with an input voltage
between 380-415 Volts. -
Connect the server to the network using RJ45 Ethernet 10/100M
connection. -
Place the server in a well-ventilated area with dimensions of
410170209 mm. -
Use the recommended coolants such as Antifreeze, Pure water, or
Deionized water with the specified pH values. -
Maintain the operation temperature between -20 to 70°C and
humidity levels between 10-90%.
FAQ
Q: What should I do if the hash rate drops significantly?
A: If you notice a significant drop in hash rate, check the
coolant flow and pressure to ensure they are within the recommended
ranges.
Q: Can I use tap water as a coolant?
A: It is not recommended to use tap water as a coolant. Stick to
the recommended coolants for optimal performance.
Q: How often should I clean the server?
A: Regular maintenance is crucial. Clean the server and cooling
system periodically to prevent dust buildup and ensure
efficiency.
“`
T19 Pro Hyd.
Product Manual
Sep. 2024
BITMAIN TECHNOLOGIES INC. www.bitmain.com
1. Specification
Product Glance
Model Version Crypto algorithm/coins Typical Hashrate, TH/s(1-1) Power on wall
@35(1-2), Watt(1-1) Power efficiency on wall@35(1-2), J/TH(1-1)
T19 Pro Hyd. Product Manual
Value
T19 Pro Hyd. k0-10
SHA256|BTC/BCH/BSV 246 5412 22.0
Detailed Characteristics
Value
Power supply
Phase Input voltage, Volt(2-1)
3 380~415
Input frequency range, Hz
50~60
Input max current, Amp
12
Hardware configuration
Network connection mode
RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm
410170209
Server size (LengthWidthHeight, with package), mm
570316430
Net weight, kg
12.8
Gross weight, kg
14.1
Environment requirements
Inlet coolant temperature, °C
20~50
Coolant flow, L/min Coolant pressure, bar
8.0~10.0 3.5
Working coolant(2-2)
Antifreeze/ Pure water/Deionized water
Coolant pH value
Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water8.5~9.5
Diameter of coolant pipe connector, mm
OD10
Storage temperature, °C
-20~70
Operation humidity(non-condensing), RH
10~90%
Notes:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%. (1-2) Inlet coolant temperature. (2-1) Caution: Wrong input voltage may cause server damaged. (2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
-2-
2. Performance Curve
(1) Hashrate vs. Inlet Coolant Temperature
T19 Pro Hyd. Product Manual
Hashrate (TH/s)
300
246
246
T19 Pro Hyd. Hashrate(3-1)
246
246
246
246
246
200 Water&Antifreeze
100
0
20
25
30
35
40
45
50
Inlet Coolant Temperature ()
(2) Power Efficiency vs. Inlet Coolant Temperature
Power Efficiency (J/T) 30
T19 Pro Hyd. Power Efficiency(3-1)
25 22
22
22
22
22.6
20
15
10
5
0
20
25
30
35
40
Inlet Coolant Temperature ()
23.4
24.3
Water&Antifreeze
45
50
(3-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.
-3-
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>