BITMAIN T19 Pro Hyd BTC Miner Instruction Manual

September 24, 2024
BITMAIN

T19 Pro Hyd BTC Miner

“`html

Specifications

Model| Version| Crypto algorithm/coins| Typical Hashrate, TH/s| Power on wall @35, Watt| Power efficiency on wall@35, J/TH
---|---|---|---|---|---
T19 Pro Hyd.| k0-10| SHA256|BTC/BCH/BSV| 246| 5412| 22.0

Detailed Characteristics

  • Power supply:

    • Phase: 3
    • Input voltage, Volt: 380~415
    • Input frequency range, Hz: 50~60
    • Input max current, Amp: 12
  • Hardware configuration:

    • Network connection mode: RJ45 Ethernet 10/100M

    • Server size (LengthWidthHeight, w/o package), mm:
      410170209

    • Server size (LengthWidthHeight, with package), mm:
      570316430

    • Net weight, kg: 12.8

    • Gross weight, kg: 14.1

  • Environment requirements:

    • Coolant flow, L/min: 8.0~10.0
    • Coolant pressure, bar: 3.5
    • Working coolant: Antifreeze/ Pure water/Deionized water
    • Coolant pH value:
    • Antifreeze: 7.0~9.0
    • Pure water: 6.5~7.5
    • Deionized water: 8.5~9.5
    • Diameter of coolant pipe connector, mm: OD10
    • Operation temperature: -20~70°C
    • Operation humidity(non-condensing), RH: 10~90%

Product Usage Instructions

To effectively operate the T19 Pro Hyd., follow these steps:

  1. Ensure the power supply phase is set to 3 with an input voltage
    between 380-415 Volts.

  2. Connect the server to the network using RJ45 Ethernet 10/100M
    connection.

  3. Place the server in a well-ventilated area with dimensions of
    410170209 mm.

  4. Use the recommended coolants such as Antifreeze, Pure water, or
    Deionized water with the specified pH values.

  5. Maintain the operation temperature between -20 to 70°C and
    humidity levels between 10-90%.

FAQ

Q: What should I do if the hash rate drops significantly?

A: If you notice a significant drop in hash rate, check the
coolant flow and pressure to ensure they are within the recommended
ranges.

Q: Can I use tap water as a coolant?

A: It is not recommended to use tap water as a coolant. Stick to
the recommended coolants for optimal performance.

Q: How often should I clean the server?

A: Regular maintenance is crucial. Clean the server and cooling
system periodically to prevent dust buildup and ensure
efficiency.

“`

T19 Pro Hyd.
Product Manual
Sep. 2024
BITMAIN TECHNOLOGIES INC. www.bitmain.com

1. Specification
Product Glance
Model Version Crypto algorithm/coins Typical Hashrate, TH/s(1-1) Power on wall @35(1-2), Watt(1-1) Power efficiency on wall@35(1-2), J/TH(1-1)

T19 Pro Hyd. Product Manual
Value
T19 Pro Hyd. k0-10
SHA256|BTC/BCH/BSV 246 5412 22.0

Detailed Characteristics

Value

Power supply

Phase Input voltage, Volt(2-1)

3 380~415

Input frequency range, Hz

50~60

Input max current, Amp

12

Hardware configuration

Network connection mode

RJ45 Ethernet 10/100M

Server size (LengthWidthHeight, w/o package), mm

410170209

Server size (LengthWidthHeight, with package), mm

570316430

Net weight, kg

12.8

Gross weight, kg

14.1

Environment requirements

Inlet coolant temperature, °C

20~50

Coolant flow, L/min Coolant pressure, bar

8.0~10.0 3.5

Working coolant(2-2)

Antifreeze/ Pure water/Deionized water

Coolant pH value

Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water8.5~9.5

Diameter of coolant pipe connector, mm

OD10

Storage temperature, °C

-20~70

Operation humidity(non-condensing), RH

10~90%

Notes:

(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%. (1-2) Inlet coolant temperature. (2-1) Caution: Wrong input voltage may cause server damaged. (2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!

-2-

2. Performance Curve
(1) Hashrate vs. Inlet Coolant Temperature

T19 Pro Hyd. Product Manual

Hashrate (TH/s)

300

246

246

T19 Pro Hyd. Hashrate(3-1)

246

246

246

246

246

200 Water&Antifreeze
100

0

20

25

30

35

40

45

50

Inlet Coolant Temperature ()

(2) Power Efficiency vs. Inlet Coolant Temperature

Power Efficiency (J/T) 30

T19 Pro Hyd. Power Efficiency(3-1)

25 22

22

22

22

22.6

20

15

10

5

0

20

25

30

35

40

Inlet Coolant Temperature ()

23.4

24.3

Water&Antifreeze

45

50

(3-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

-3-

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals