PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover Instruction Manual

August 23, 2024
PARKSIDE

PARKSIDE logo AIR FILTER REGULATOR & LUBRICATOR PDWE 8 C3
AIR FILTER REGULATOR & LUBRICATOR

Translation of the original instructions

PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover

PDF ONLINE
www.lidl-service.com

IAN 435173_2304

Before reading, fold out the page with the images and familiarise yourself with all the features of the device.

PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover - Figure
1

Introduction

Congratulations on the purchase of your new appliance. You have chosen a high- quality product. The operating instructions are an integral part of this product. It contains important instructions for safety, use and disposal. Familiarise yourself with all operating and safety instructions before using the product. Only use the product as described and for the specified areas of application. Hand over all documents when passing the product on to third parties.

1.1 Intended Use
This unit is used to lubricate the compressed air for pneumatic tools and filters condensate from the compressed air during this process. Do not use this compressed air maintenance unit in explosive environments. Avoid working in environments where substances such as flammable gases, liquids and paint and dust mists are present. Any other use or modification of the unit is considered improper, involves considerable risk of accident and is also not permitted. We accept no liability for damage resulting from improper use. The unit is intended for private use only and may not be used for commercial or industrial purposes.

1.2 Scope of Delivery
1 Air Filter Regulator & Lubricator including connections
2 Mounting screws
2 Dowels
1 Instruction manual

1.3 Equipment

1 Compressed air regulator
2 Wall bracket
3 Oil refill inlet
4 Oil passage screw
5 Quick coupling
6 Locking ring
7 Container for compressed air oil
8 Drain valve| 9 Condensate collector
10 Filter insert
11 Compressed air manometer
12 1/4″ plug nipple (pre-assembled)
13 Oil fogger unit
14 Filter unit
15 Mounting screws
16 Dowels
---|---

1.4 Technical Data
Working pressure: max. 8 bar

Explanations of all symbols

| WARNING
Read the operating instructions before commissioning.
---|---
| Wear eye protection
| Wear respiratory protection
| Wear hearing protection
| Wear protective gloves

General safety instructions

Read all safety notes and instructions.

Filure to comply with the safety information and instructions can cause serious injury and/or damage to property.

Keep all safety notes and instructions for future reference!

  • This appliance can be used by persons aged 16 years and over and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
  • In conjunction with a compressor, the compressed air maintenance unit is used for the maintenance and care of your compressed air tools. The compressed air maintenance unit may only be used with an air compressor. When using the unit, observe the technical data of the connected tools and check them regularly during use.
  • Part of the intended use is also the consideration of the safety instructions contained in the operating instructions.
  • Persons who use the compressed air maintenance unit and carry out maintenance work are obliged to familiarise themselves with it. Furthermore, they must be informed about potential dangers. The applicable accident prevention regulations must be observed correctly and conscientiously.

2.1 Safety instructions for the use of compressed air equipment

  • RISK OF INJURY! Disconnect the compressed air supply before tool changes, adjustment and mainte nance work.
  • When loosening a connection, always hold the compressed air hose firmly in your hands. The whipping recoil of the compressed air hose can cause injuries.
  • The compressed air maintenance unit must be installed before it can be safely put into operation.
  • The compressed air maintenance unit may only be connected to a compressed air source that does not exceed the working pressure of 8 bar.
  • Do not place the compressed air lines near heat, oils, heat and sharp edges.
  • The compressed air maintenance unit may only be operated in conjunction with an air compressor. The use of other sources of compressed air, such as a compressed air cylinder, is prohibited. There is a risk of fire and/or explosion.
  • Make sure that you keep children and persons with limited physical or mental abilities away from the compressed air maintenance unit and from connected compressed air tools.
  • When carrying out maintenance, adjustment and repair work, always disconnect the compressed air maintenance unit from the compressed air supply first.
  • Only use the compressed air maintenance unit if it is in immaculate condition. If in doubt, first consult a specialist before use.
  • Only have repairs carried out by qualified specialists.

Preliminary Measures prior to Starting Up

3.1 Wall mounting

  • For wall mounting, use the wall bracket 2 for marking on the wall and for screwing with the supplied mounting material (see scope of delivery, Fig. D).

PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover - Wall
mounting

3.2 Filling the oil nebuliser unit

  • Remove the oil reservoir 7 by turning the locking ring 6 clockwise (see fig. E). Fill the oil reservoir 7 with suitable compressor oil until the maximum mark is reached (see fig. B on the fold-out page).
  • Subsequently, tighten the oil reservoir 7 only manually (without tools) by hand in an anti-clockwise direction.PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover - Filling the oil nebuliser unit

Commissioning

  • Connect the compressed air supply line of the tool to be connected to the quick coupling 5 of the compressed air maintenance unit. A triangle „▶“ on the surface of the unit indicates the direction of flow of the compressed air.
  • First release the lock by pulling the compressed air regulator 1 upwards (see fig. F).
  • Set the compressed air regulator 1 to the lowest level by turning it anticlockwise. The desired settings are adopted by pressing the compressed air regulator 1 down.
  • Connect the compressed air supply line of the compressed air source to the plug nipple 12 of the compressed air maintenance unit. Directly at the inlet there is a triangle „▶“ on the surface indicating the direction of flow of the compressed air.

PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover -
Commissioning

4.1 Setting the working pressure
After connecting the compressed air maintenance unit to a compressed air source, you can set the desired operating pressure using the compressed air regulator 1.
The working pressure of the compressed air source is indicated on the compressed air manometer 11.

  • First release the lock by pulling the compressed air regulator 1 upwards (see fig. F).
  • Turning counterclockwise reduces the pressure. Turning clockwise increases the pressure.
  • Lock the setting by pressing the compressed air regulator 1 down.

4.2 Filter unit

  • The filter unit 14 is linked to the compressed air regulator 1. The maximum working pressure is 8 bar and the operating pressure is adjustable from 0.5 – 8 bar. The filter unit 14 is used to filter condensate and stores the condensate in the condensate collection tank 9.
  • You can check the condensate level through the transparent viewing surfaces (see fig. C on the fold-out page). The stored condensate can be drained via the drain valve 8.

4.3 Condensate drain

  • It is prohibited to use the filter unit 14 without the condensate collection tank 9 mounted.

NOTE
Make sure that the compressed air maintenance unit has been disconnected from the compressed air source before emptying the condensate collection container 9. Otherwise the collected condensate may spray out uncontrolled.
The drain valve 8 opens as soon as it is disconnected from the compressed air.
To empty the stored condensate from the condensate – collection container 9, use an appropriate container.
Press from below against the drain valve 8 fig. (see G), this opens and the condensate flows into the container.

PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover - against the
drain valve

4.4 Oil mist unit
The oil fogger unit 13 is linked to the filter unit 14. Its function is to oil the filtered compressed air.
You can check the fill level of the oil reservoir 7 through the viewing surfaces. Only use suitable oil for this compressed air maintenance unit.

  • Remove the maintenance unit from the compressed air source before adding oil.
  • Turn the oil passage screw 4, which is mounted on the sight glass, clockwise (“-” ) to decrease the required amount of oil. Turn it anticlockwise (“+” ) to increase the amount of oil.
  • The integrated sight glass enables constant monitoring of the filtered compressed air.
  • To refill oil, unscrew the screw of the oil refill inlet 3 with a suitable Allen key. Fill the reservoir using a suitable funnel and then tighten the screw again with the spanner.
Error Cause Solution
The lubrication is not sufficient. Oil passage screw 4 is closed too far in

the direction
(“-“).| Increase the amount of oil.
The compressed air oil quantity is too low, i.e. below the
minimum filling quantity.| Pour more oil into the oil reservoir 7.
Pay attention to the maximum filling quantity.
The operating pressure of the compressed air is too weak.| The pressure regulator 1 is turned too tight.| Increase the pressure.

Maintenance, cleaning and storage

WARNING! RISK OF INJURY! Disconnect the unit from the compressed air source before carrying out maintenance work.
NOTE
The compressed air maintenance unit must be serviced and overhauled regularly for proper functioning and to comply with safety requirements. Improper and incorrect operation can lead to failures and damage to the unit.

  • Never use abrasive and/or scratching cleaning agents or solvents. These could damage the plastic parts of the compressed air maintenance unit.
  • Make sure that water never gets inside the oiler.
  • Make sure that the housing and the inside of the compressed air maintenance unit remain free of dust and dirt. To do this, regularly wipe the compressed air maintenance unit with a clean cloth.
  • Clean the compressed air maintenance unit and the connections at regular intervals with a damp cloth.
  • Empty the condensate collection container 9 of the compressed air maintenance unit at regular intervals. To do this, press the drain valve 8 (see fig. G) on the underside upwards. Note that the compressed air maintenance unit must be pressure-free for safety. Disconnect the compressed air maintenance unit from the compressed air source. The release valve 8 opens as soon as it is disconnected from the compressed air.

Disposal

  • The pneumatic power tool, accessories and packaging* should be recycled in an environmentally friendly manner.
  • For information on how to dispose of the discarded machine and accessories, please contact your local council or town/city administration.

The packaging is made of environmentally friendly materials that you can dispose of at your local recycling centres.

PARKSIDE PDWE 8 C3 Sheet Metal Nibbler Needle Rust Remover - Symbol
8

The Triman logo is valid in France only.

Observe the labelling of the packaging materials when separating waste; these are marked with abbreviations (a) and numbers (b) with the following meaning: 1–7: Plastics/20–22: Paper and cardboard/80-98: Composites.

6.1 Environmental compatibility and Material disposal

Lubricating oil must not get into the soil, water or waste water. Lubricating oil is special waste that must be disposed of accordingly. Observe the local regulations. Dispose of the lubricating oil as well as packaging containing residues at your local collection point, petrol station or oil dealer.

  • Non-contaminated or cleaned packaging can be recycled.

ROWI Germany GmbH Warranty

Dear Customer,
This appliance has a 3-year warranty valid from the date of purchase. If this product has any faults, you, the buyer, have certain statutory rights. Your statutory rights are not restricted in any way by the warranty described below.

Warranty conditions
The validity period of the warranty starts from the date of purchase. Please keep your original receipt in a safe place. This document will be required as proof of purchase.

If any material or production fault occurs within three years of the date of purchase of the product, we will either repair or replace the product for you or refund the purchase price at our discretion. This warranty service is dependent on you presenting the defective appliance and the proof of purchase (receipt) and a short written description of the fault and its time of occurrence.

If the defect is covered by the warranty, your product will either be repaired or replaced by us. The repair or replacement of a product does not signify the beginning of a new warranty period.

Warranty period and statutory claims for defects
The warranty period is not prolonged by repairs effected under the warranty. This also applies to replaced and repaired components. Any damage and defects present at the time of purchase must be reported immediately after unpacking. Repairs carried out after expiry of the warranty period shall be subject to a fee.

Scope of the warranty
This appliance has been manufactured in accordance with strict quality guidelines and inspected meticulously prior to delivery.

The warranty covers material faults or production faults. The warranty does not extend to product parts subject to normal wear and tear or fragile parts such as switches, batteries or those made of glass.
The warranty does not apply if the product has been damaged, improperly used or improperly maintained. The directions in the operating instructions for the product regarding proper use of the product are to be strictly followed. Uses and actions that are discouraged in the operating instructions or which are warned against must be avoided.
This product is intended solely for private use and not for commercial purposes. The warranty shall be deemed void in cases of misuse or improper handling, use of force and modifications/repairs which have not been carried out by one of our authorised Service centres.

Warranty claim procedure
To ensure quick processing of your case, please observe the following instructions:

  • Please have the till receipt and the item number (IAN 435173_2304) available as proof of purchase.
  • You will find the item number on the type plate on the product, on the front page of the instructions (bottom left), or as a sticker on the rear or bottom of the appliance.
  • If functional or other defects occur, please contact the service department listed either by telephone or by e-mail.
  • You can return a defective product to us free of charge to the service address that will be provided to you. Ensure that you enclose the proof of purchase (till receipt) and information about what the defect is and when it occurred.

PDF ONLINE
www.lidl-service.com

At www.lidl-service.com you can download this manual as well as many other manuals, product videos and installation software. This QR code will take you directly to the Lidl service page (www .lidl-service.com) and allow you to open your operating instructions simply by entering the article number (IAN 435173_2304).

Service

If any problems occur during use of your ROWI Germany product, please proceed as follows:

Contact us
You can contact the service team of ROWI Germany at:

ROWI Germany GmbH
Werner-von-Siemens-Str. 27
76694 Forst
GERMANY
Lidl-services@rowi-group.com
Service-Hotline: +800 7694 7694
(free call from a German landline)

IAN 435173_2304
Most problems can be resolved with the skilled technical support of our Service Team.

ROWI GERMANY GMBH
WERNER-VON-SIEMENS-STR. 27
DE-76694 FORST
GERMANY
Last Information Update: 09/2023
ID No.: PDWE8C3-092023-LB08-01
IAN 435173_2304

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals