Product Information
The product is a device that provides multi-level authorization for secure access. It has connection ports for antennas, power supply, and wired switches. The device has a relay with Normally Open (NO), Common (COM), and Normally Close (NC) ports. It also hasa dry contact that can be connected to a wired switch. The device supports basic communication functions for SMS and calling using a nano SIM card.
Product Usage Instructions
- Authorization: To authorize super(admin) users, send the command “pwd1234” (without quotes) via SMS. To authorize normal users, send the command “pwd0000 1234#TELphone number#user ID#” (without quotes) via SMS. Note that only G203 supports normal users.
- Connecting: Connect the device as per the connecting diagram provided in the user manual.
- Operation: Follow the commands list provided in the user manual to operate the device.
- Resetting: To reset the device, press the reset button for 5 seconds. This will delete all parameters before authorization. If reset is successful, the RUN light will flash 4 times quickly, and the device will short power off and restart. To enter silent status, press the reset button twice quickly. To reset the device four times quickly, press the reset button four times. After successful restart, the device will feedback information to the super administrator via SMS.
- Commands: Use the commands list provided in the user manual to authorize users, access relay, keep relay on/off, check relay status, and check signal value.
Products instruction
Based on GSM/3G/4G communication protocol, supports 1001 authorized users.
Authorized users can remotely control the equipment, systems and machines
connected to the product by SMS commands & free calling. It is widely used in
access control systems, garage doors, swing doors ,folding doors,sliding
doors, parking system and the equipments that can be connected to the relay
control , the G202PLUS gate controller & G203 gate controller will send a
notification (via SMS) to the user of the result of the remote control (such
as the opening and closing status of the gate).
With real authorize and multi-level authorization, more security. no authorize
no access, even if you know the password.
Physical Layout
Connectiong port and lightings
| ANT | Antennas port |
|---|---|
| Signal | Signal light: |
- Registering the network signal: flashes quickly, once per second
- __ The network registration is successful: flashes quickly, flash every 2 seconds
- __ Reset successfully; quick flash 4 times
Run| Run light:
- Device is loading SMS function: long light about 2 seconds
- __ Loading and process SMS successfully :slowly flash, flash every 2 seconds
- __ Reset successfully; quick flash 4 times;
Relay| Relay light: Relay on: lighting, relay off: off
Reset button| Reset button:
- Press for 5 seconds to reset, it will delete all parameters before authorized. reset successfully ,the RUN light will flash 4 times quickly ,then device will short power off and restart
- Quickly press the reset button 2 times, the run and signal light will enter a slient status, press the reset button quickly 1 time, the light will return normal flash.after the device reset or power on again, the light also will return normal flash.
- Quickly press 4 times to reset device:
After the restart is successful, the device will feed back information to the super administrator via SMS
| DC | + | Power supply input, Positive wire. |
|---|---|---|
| 9~36V | – | Power supply input, Negative wire. |
| --- | --- | --- |
| Relay Output | NO | Normally Open port. The relay is 3A/240VAC. |
Connect to the switch of the electric lock or device.
COM| Common port. The relay is 3A/240VAC. Connect to the switch of the
electric lock or device.
NC| Normally Close port. The relay is 3A/240VAC. Connect to the switch
of the electric lock or device
Wired Switch| Dry contact, used to be connected with wired switch, like
push button. Notice: It should not be connected with voltage input
Technical parameters
- Rated Voltage: DC 9V~36V/1A
- Working temperature: -10℃~+60℃
- Storage temperature: -20℃~+60℃
- Relative humidity: 10-90%, No condensation
- Work frequency:
- GSM: 850/900/1800/1900MHz
- 3G WCDMA: 900/2100 MHz UMTS
- 3G CDMA2000:850/1900MHz UMTS
- 3G: 850/2100MHz UMTS
- 4G:
- C:GSM:900/1800,LTE-FDD B1/B3/B5/B8 LTE-TDD:B34/B38/B39/B40/B41
- E:GSM:900/1800,LTE-FDD B1/B3/B5/B7/B8/B20
- SA:GSM:850/900/1800/1900M LTE-FDD B1/B3/B5/B7/B8/B28/B66 Communication protocol: GSM PHASE 2/2+ (include data service) Related Voltage of the Output Relay: 3A/240V AC
- SIM Card:Nano type, 3V
- Antenna: 50 Ω SMA
- Wired Switch: Supports
- Dimension: 96.55031.5mm
- Net Weight: 88g
- Relay port:
- Contact Capacity :5 Amps at 250VAC Cosφ=1. 20 Amps at 14VDC
Installation
- A nano SIM card support basic communication function for SMS and calling, close the PIN lock
- Connecting diagram
- Follow the commands list to operate
- After the first authorize successfully, follow the commands list and the user manual to do other settings
Connecting diagram:
Commands list and note
Command name| Commands list, All the commands do not attach “[]”
super(admin) pwd : 1234 normal users pwd : 0000|
Note| Who can use the commands
---|---|---|---
Authorize super(admin) users| 1234#TEL【phone number】#DEF#| This command
to authorizes the new user to be the super(admin) user, and automatically
assign a user ID, the user ID is 001-999 (The first user authorized is the
super administrator user by default)| Super(admin) users
1234#TEL【phone number】#【user ID】#| This command authorizes the new user to be
the super(admin)
user, you need edit the user ID by yourself。
(User ID rules: English letters, numbers or combinations, if it is a pure
number within 3 digits, it will be the user ID.)| Super(admin) users
Authorize normal users (only G203 support to normal users)|
1234#NORTEL【phone number】#DEF#| This command authorizes a new phone number to
be a normal user, and automatically assign a user ID, the user ID range is
001-999| Super(admin) users
1234#NORTEL【phone number】#【user ID】#| This command authorizes the new user to
be a normal user, you need edit the user ID by yourself
(User ID rules: English letters, numbers or combinations, if it is a pure number within 3 digits, it will
be the user ID.)
| Super(admin) users
Calling to access| **–| Calling to access the device, device will
hang up automatically| All authorized users
Relay on| 1234#ON#
0000#ON#| Relay on by SMS, if there is relay delay time settings, the relay on
time follow the relay delay setting.| All authorized users
****Keep relay always on| ** 1234#KPON#
0000#KPON#| ** Keep the relay on , until you off it by SMS or call| All
authorized users
Relay off**| 1234#OFF#
0000#OFF#
| Relay off| ** All authorized users
Check the relay status| ** 1234#RELAY?
0000#RELAY?| Check the relay status on or off| All authorized
users
---|---|---|---
Check the signal value| 1234#CSQ?
0000#CSQ?| Check the signal value| All authorized users
Check users| 1234#TEL【user ID】?| Check the user phone number by
user ID| Super(admin) users
1234#QRYTEL【phone number】?| Check the users by phone number|
Super(admin) users
1234#TELALL?| Check all users| Super(admin) users
Delete users| 1234#TEL#【user ID】#| Delete users by user ID, the super
admin user can not be deleted| Super(admin) users
** 1234#DELTEL#【phone number】#| Delete the user by phone number, the super
admin user can not be deleted| Super(admin) users
Change Super(admin) password| 1234#PWD【new password】#PWD 【new
password】#| Change the super(admin) password password rules: The number of
digits is 4-12 characters, case- sensitive, and letters and numbers are
supported.| Only super admin
****Change normal user password
(only G203 support this)| 1234#NORPWD【new password】 #NORPWD【new password】#|
Change the normal user password password rules: The number of digits is 4-12
characters, case- sensitive, and letters and numbers are supported| Only super
admin
Set the relay delay time (G202PLUS)| 1234#GOT【time】#| Set the relay
closing time, the relay will follow this setting time after closing, and then
disconnect, the delay time can be set 0-999s| Super(admin) users
****Set the relay delay time**
(G203 )
| 1234#GOT【time】#| Set the relay closing time, the relay will follow this
setting time after closing, and then disconnect, the delay time can be set
0-9999s| Super(admin) users
Check the relay delay time| ** 1234#GOT?| | Super(admin) users
---|---|---|---
Allow all phone number call to access relay| ** 1234#AA#| Allow all
phone number call to access it| Super(admin) users
Only allow authorized users access it| ** 1234#AU#| | Super(admin)
users
Check who can access device| ** 1234#AC?| | Super(admin) users
add notification push users (only G203 support)| 1234#PUSH【phone
number】#| Add Max 3 extra users to receive all relay action feedback,(the
super admin default be the nitofication push user), the other 2 notification
users do not be included in the 999users| Super(admin) users
Check all notification push users| ** 1234#PUSHALL?| | Super(admin)
users
Delete notification push users
(only G203 support this)| 1234#DELPUSH#【phone number】#| ** After delete,
will not receive the relay action feedback| Super(admin) users
Allow SMS feedback| 1234#R#| Default open the SMS feedback|
Super(admin) users
Do not allow SMS feedback| 1234#N#| | Super(admin) users
Check the notification push status| 1234#M?| | Super(admin) users
**Modify your own phone number**| 1234#MODTEL#【new phone number】#【new
phone number】#| Modify your phone number to a new, your old phone number will
lost all permission after modified
| Super(admin) users
Remote reset| 1234#RESET#| Delete all settings, the super admin will
receive one SMS to inform reset successfuly| Only super admin user
**Remote reboot| ** 1234#REBOOT#| Reboot the device, but| Only super
admin user
common problem:
- After authorized, why the device does not respone the commands or calling?
Due to the different communication methods of operators in different
countries, the actual number recognized by the device may be different. For
example, your authorized number is +86 12345678, and the actual device
acquisition number may be 12345678, resulting in invalid authorization.
When the authorized number to send the instruction and dial the telephone
device does not correspond, you can use this number to send the verification
instruction to the device to verify whether the authorized number you filled
in is correct. The instructions are as follows:
0000#CHECKTHEPHONE#
The device will feedback: YOUR Phone Num:XXXXXXXXX to re-authorize the number
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>