INTEREQUIP BulletPro Elite X6-X8 Fuel Injector Cleaner User Manual
- June 5, 2024
- INTEREQUIP
Table of Contents
INTEREQUIP BulletPro Elite X6-X8 Fuel Injector Cleaner

Security Information
The Elite X6/X8 is designed for voltage AC 180~264V or AC 90~132V. Please wear glasses to avoid liquid slashing into the eyes and please wear gloves when operating the machine.
Machine Introduction
Front View
- Fuel Rail
- Pulse Line
- Inspection Tubes
- LED Lights
- Color LCD
- Fuel Pipe For Injector
- Bolt
- Fuel Injector of Standard International Connector
- Ultrasonic Bath
- Tray
- Oil Pressure Gauge
- Button
Side View

Rear View

Panel
Key Instructions

Accessories

Technical Spec
-
Voltage: AC 180~264V or AC 90 ~132V
-
Power: 300W
-
Fuse: 5A
-
Fuel Pressure: 0~6.5 bar
Display: LCD 4.3 inch color display -
Working Temperature: from 10 to 45 degree
-
Ultrasonic Power: 100 W
-
Dimensions: 370 mm 430 mm 450 mm
-
Gross Weight: 28 kg
Instructions
Installation Drawing

Top Feed Injectors Installation

Side Feed Injectors Installation
Instructions on machine operation

How to Use the Ultrasonic Bath

Maintenance
The Elite X8 fuel injector cleaner hydraulic system has 2 stage filtering. When the LED light on panel is turned on for more than 30 minutes, user should replace the filter. If filter is not replaced, the pump can be damaged.
Attachment

Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>