ALLEN HEALTH DT20 2-In Dante Expander with Power Supply User Guide

June 6, 2024
ALLEN HEALTH

ALLEN HEALTH DT20 2-In Dante Expander with Power Supply

DT20

The DT20 is a portable, PoE-enabled, rugged Dante I/O unit. It can be used to complement Allen & Heath digital mixing systems, or any other system on a Dante network. It provides 2 mic/line preamps with local gain and phantom power control. It connects to the Dante network over a single Cat cable. The DT20 can be ordered in either of two versions:

  • DT20 – standard version with rubber feet and 12V power supply.
  •  DT20-M – version for fixed installation with brackets for surface mounting and no external power supply.
Software

Visit the Audinate website to learn more about Dante, and download Dante Controller to route audio and configure devices on a Dante network: https://www.audinate.com/

Specification

Mic/Line Inputs|
---|---
Mic Inputs| Balanced XLR, +48V phantom
Analogue Gain| 0 to +55dB
Line Inputs| Balanced TRS, -20dB PAD
Maximum Input Level| +30dBu (TRS in)
Input Impedance| >4kΩ (XLR), >10kΩ (TRS)
Dante| 48kHz/96kHz
Power and Temperature|
DC Input| +12V DC 1.25A
Power Consumption| 10W max
Operating Temperature Range| 0°C to 40°C (32°F to 104°F)
PoE Requirements| 802.3af 15W
Dimensions and Weight| Width x Depth x Height x Weight
DT20| 130 x 136 x 43 mm, 0.5kg

(5.1” x 5.4” x 1.7”, 1lbs)

Surface mounting

The surface mounting ears allow the device to be mounted on top or under a surface, desktop or podium, or vertically on a wall or partition. They can be installed to face either the top or bottom of the unit. The DT20-M comes with surface mounting ears and preassembled insert bars. Position the ears centrally on each side of the unit, aligned with the threaded holes on the insert bars, facing either up or down as required, and secure them using the 4x M3x6mm screws provided in the package. For surface mounting of a standard DT20, the optional surface mounting kit DT-SMK is available.

Rack mounting

Up to two units can be rack-mounted in a single 1U rack space with the optional rack kit DT-RK19. Read the Safety Instructions Sheet included with the product and the information printed on the panel before operating. A limited one year manufacturer’s warranty applies to this product, the conditions of which can be found at: www.allen-heath.com/legal 

Front Panel

  1. Input sockets Balanced combi mic/line inputs. The TRS inputs have an integrated 20dB Pad for use with line-level signals.
  2. Gain Rotary control for the analog gain of the preamp, 0dB to 55dB. To prevent any tampering with the gain level, the knobs can be removed and replaced with the blanking lids provided.
  3. pp + 48V Phantom Power switch and indicator.
Rear panel

  1.  Dante EtherCon port for connection to the Dante network and Link / Activity LED indicator. Use a PoE Ethernet switch or PoE injector to power the unit via this port.
  2. Power LED indicator and Ready indicator. Ready lights up when the unit is successfully booted and ready to pass audio.
  3. Factory Reset Hold down the recessed switch while powering up. After at least 10 seconds, remove power then power up again normally to reset the network settings and name. This will delete any static IP address and revert to factory default (DHCP / zero-conf).
  4. DC input DC 12V connector. Only use with the power supply provided with the unit.