MEAN WELL LRS-150-12 150W Single Output Switching Power Supply Installation Guide
- August 20, 2024
- MEAN WELL
Table of Contents
150W Single Output Switching Power Supply
LRS- 150 series User’s Manual
https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf
Features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.5W
- Miniature size and 1U low profile
- High operating temperature up to 70°C
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, 2-16 for household appliances
- Operating altitude up to 5000 meters
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- Over voltage category III
- 100% full load burn-in test
- 3 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
LRS-150 series is a 150W single-output enclosed type power supply with 30mm of
low profile design. Adopting the input of 115VAC or 230VAC(selectable by
switch), the entire series provides an output voltage line of 12V, 15V, 24V,
36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case
enhances the heat dissipation of LRS-150 that the whole series operates from
-30°C through 70°C under air convection without a fan. Delivering an extremely
low no load power consumption (less than 0.5W), it allows the end system to
easily meet the worldwide energy requirement. LRS-150 has the complete
protection functions and 5G anti- vibration capability; itis complied with the
international safety regulations such as TUV BS EN/EN62368-1, BS
EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB 4943.1. LRS-150 series
serves as a high price-to-performance power supply solution for various
industrial applications.
Model Encoding
SPECIFICATION
MODEL| LRS-150-12| LRS-150-15| LRS-150-24|
LRS-150-36| LRS-150-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 12.5A| 10A| 6.5A| 4.3A| 3.3A
CURRENT RANGE| 0 ~ 12.5A| 0 ~ 10A| 0 ~ 6.5A| 0 ~ 4.3A| 0 ~ 3.3A
RATED POWER| 150W| 150W| 156W| 154.8W| 158.4W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2
~ 52.8V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC
500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)| 40ms/230VAC
35ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ~ 132VAC / 170 ~ 264VAC by switch
240 ~ 370VDC(switch on 230VAC)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 87.5%| 88.5%| 89%| 89%| 90%
AC CURRENT (Typ.)| 3A/115VAC 1.7A/230VAC
INRUSH CURRENT (Typ.)| COLD STAR 60A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION| OVER LOAD| 110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 13.8 ~ 16.2V| 18.75 ~ 21.75V| 28.8 ~ 33.6V| 41.4 ~ 48.6V| 55.2 ~
64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS
EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 7)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, BS
EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC
004,KC K60950-1(for LRS-150-12 only), BIS IS13252(Part1): 2010/IEC 60950-1:
2005(NOTE 9), AS/NZS 62368.1(by CB) approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS
EN/EN61000-3-2 Class A(≤75% Load), BS EN/EN61000-3-3,GB17625.1,GB/T 9254.1,
BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2
(BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC
KN32,KN35(for LRS-150-12 only)
OTHERS| MTBF| 2707.7K hrs min.
Telcordia SR-332 (Bellcore) ;
558.2Khrs min.
MIL-HDBK-217F (25℃)
DIMENSION| 1599730mm (LWH)
PACKING| 0.48Kg ; 30pcs/15.4Kg/0.75CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input,
rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the
power supply very quickly may lead to increase of the set up time.
7. The power supply is considered a component which will be installed into a
final equipment. All the EMC tests are been executed by mounting the unit on a
360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to ”EMI testing of component power supplies.”
(as available on
https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
8. The ambient temperature derating of 5℃/1000m is needed for operating
altitude greater than 2000m (6500ft).
9. Some model may not have the BIS logo, please contact your MEAN WELL sales
for more information.
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
Case No.241A
Unit:mm
Terminal Pin No. Assignment
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4,5 | DC OUTPUT -V |
2 | FG | 6,7 | DC OUTPUT +V |
3 | AC/N |
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Documents / Resources
| MEAN
WELL LRS-150-12 150W Single Output Switching Power
Supply
[pdf] Installation Guide
LRS-150-12, LRS-150-15, LRS-150-24, LRS-150-36, LRS-150-48, LRS-150-12 150W
Single Output Switching Power Supply, LRS-150-12, 150W Single Output Switching
Power Supply, Output Switching Power Supply, Switching Power Supply, Power
Supply, Supply
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>