MEAN WELL GST220A48-R7B Reliab Green Industrial Adaptor User Manual

August 17, 2024
MEAN WELL

MEAN WELL GST220A48-R7B Reliab Green Industrial Adaptor

Global certificates

  • Universal AC input / Full range
  • 3 pole AC inlet IEC320-C14, Class I power unit
  • Built-in active PFC function
  • No load power consumption<0.15W

Energy efficiency Level VI

  • Comply with EISA 2007/DoE, NRCan, AU/NZ MEPS,

EU ErP and CoC Version 5

  • Protections: Short circuit / Overload / Over voltage /Over temperature
  • Fanless design with -30~+70°C working temperature
  • Fully enclosed plastic case
  • I ED indicator for power on
  • Various DC plug quick adapter accessories available (Plug kit sold separately, please refer to: https://www.meanwell.com/upload/pdf/DC_plug.pdf))
  • 3 years warranty

Applications

  • Consumer electronic devices
  • Telecommunication devices
  • Office facilities
  • Industrial equipments

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

GST220A is a highly reliable, 220W desktop-style single-output green adaptor series. This product is a class 1 power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With an efficiency of up to 94.5% and the extremely low no-load power consumption below 0.15W, GST220A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea K-MEPS, EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save energy when it is either in operating mode or the standby mode. The entire series utilizes the 94V-0 flame-retardant plastic case.GST220A is certified for the international safety regulations.
Model Encoding

SPECIFICATION

ORDER NO.| GST220A12- R7B| GST220A15- R7B| GST220A20- R7B| GST220A24- R7B| GST220A36- R7B| GST220A48- R7B
---|---|---|---|---|---|---








OUTPUT

| SAFETY MODEL NO.| GST220A12| GST220A15| GST220A20| GST220A24| GST220A36| GST220A48
DC VOLTAGE **Note.2| 12V| 15V| 20V| 24V| 36V| 48V
RATED CURRENT| 15A| 13.4A| 11A| 9.2A| 6.1A| 4.6A
CURRENT RANGE| 0 ~ 15A| 0 ~ 13.4A| 0 ~ 11A| 0 ~ 9.2A| 0 ~ 6.1A| 0 ~ 4.6A
RATED POWER (max.)| 180W| 201W| 220W| 221W| 219.6W| 221W
RIPPLE & NOISE (max.) Note.3| 80mVp-p| 100mVp-p| 120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±2.0%| ±2.0%
SETUP, RISE TIME ****Note.6| 2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 20ms / 230VAC         20ms / 115VAC at full load





INPUT

| VOLTAGE RANGE **Note.7| 85 ~ 264VAC  120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.91 / 230VAC         PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)| 90%| 90%| 92%| 93.5%| 93%| 94.5%
AC CURRENT (Typ.)| 4A / 115VAC         2A / 230VAC
INRUSH CURRENT (max.)| Cold start 95A / 115VAC       120A / 230VAC
LEAKAGE CURRENT(max.)**| 0.75mA / 240VAC




PROTECTION

| ****

OVERLOAD

| 105 ~ 135% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed


OVERVOLTAGE

| 105 ~ 135% rated output voltage
Protection type: Hiccup mode @ 10%load
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0~50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes














SAFETY & EMC

(Note. 10)

| ****

SAFETY STANDARDS Note. 8

| UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 ,

BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved

(UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 for GST220A36-R7B)

WITHSTAND VOLTAGE| I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG:SHORT
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH






EMC EMISSION

| Parameter| Standard| Test Level / Note


Conducted emission

| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22

CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32

| ****

Class B


Radiated emission

| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22

CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32

| ****

Class B

Harmonic current| BS EN/EN61000-3-2,GB9254| Class A
Voltage flicker| BS EN/EN61000-3-3| ——-







EMC IMMUNITY

| BS EN/EN55035
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 2, 1KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line , 2KV/Line-FG
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 2, 3A/m
Voltage dips, interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 2006.1K hrs min.     Telcordia SR-332 (Bellcore); 209.4K hrs min.     MIL-HDBK-217F (25℃)
DIMENSION| 2108546mm (LWH)
PACKING| 1.1Kg; 12pcs/14.2Kg/0.81CUFT


CONNECTOR

| PLUG| See page 4~5; Other type available by customer requested
CABLE| See page 4~5; Other type available by customer requested





NOTE

| 1.  All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.

2.  DC voltage: The output voltage set at the point measure by the plug terminal & 50% load.

3.  Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μF & 47μF capacitor.

4.  Tolerance: includes set up tolerance, line regulation, and load regulation.

5.  Line regulation is measured from the low line to the high line at the rated load.

6.  Length of set up time is measured at the first cold start. Turning ON/OFF the power supply may lead to increase of the set-up time.

7.  Derating may be needed under low input voltage. Please check the derating curve for more details.

8.  The demand for Malaysia safety is processed with order no. GST220A  -SIRIM by request. Please contact MEAN WELL for details.

9.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

10.  The power supply is considered as an independent unit, but the final equipment still needs to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Derating Curve

Static Characteristics

Mechanical Specification

DC output plug

Standard plug: R7B

DC plug changeable through

  1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
  2. Quick adapter accessory (sold separately without MOQ)
    Please refer to below table and online selection guide :https://www.meanwell.com/upload/pdf/DC_plug.pdf

Example quick adapter accessory:

Optional DC plug: (Available in customized cable or quick adapter)

Installation Manual

Please refer to: http://www.meanwell.com/manual.html

FAQ

  • Q: What are the global certificates this product holds?
  • A : The product holds UL62368-1, BS EN/EN62368-1, R33100 RoHS, J62368-1, K60950-1, AS/NZS60950-1, GB4943.1 IS13252, MS IEC60950-1 (optional) certifications.
  • Q : What are the protection features of this industrial adaptor?
  • A : The adaptor provides protection against overload, overvoltage, and over-temperature conditions. It enters Hiccup mode for overload and overvoltage protection and shuts down in case of over-temperature.

User’s Manual

Video

Documents / Resources

| MEAN WELL GST220A48-R7B Reliab Green Industrial Adaptor [pdf] User Manual
GST220A48-R7B, GST220A36-R7B, GST220A48-R7B Reliab Green Industrial Adaptor, GST220A48-R7B, Reliab Green Industrial Adaptor, Green Industrial Adaptor, Industrial Adaptor, Adaptor
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals