BEGA 85022 Compact flood lights Instruction Manual

August 17, 2024
BEGA

BEGA 85022 Compact flood lights

Specifications

  • Power consumption of 85 022 : 0.07 A
  • Lamp Module connected wattage: 12 W
  • Luminaire connected wattage: 14 W
  • Rated temperature : 25°C
  • Ambient temperature: 40°C

Product Usage Instructions

Safety Information

The installation and operation of this luminaire are subject to national safety regulations. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website at www.bega.com.

Adjustment of Beam Direction

To adjust the beam direction, undo the joint screw using a hexagon socket head wrench size 5 mm, set the desired beam direction, and then tighten the joint screw.

Note: Do not remove the desiccant bag from theluminaire housing as it is needed to remove residual moisture.

FAQ

  • Q : Can I replace the connecting cable myself?
  • A : The connecting cable may only be replaced by a qualified electrician to ensure safety and proper installation.

dimension

Application

Portable compact floodlight BEGA UniLink® with earth spike and 5 m connecting cable with plug connector. A separate mains plug must be ordered in order to connect the floodlight to the mains. The various country-specific mains plug with 0.5 m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product description

  • Floodlight made of aluminum alloy, aluminum, and stainless steel  BEGA Unidure® coating technology Colour graphite
  • Earth spike made of glass fiber reinforced synthetic material Safety glass with optical structure
  • Silicone gasket Reflector surface made of pure aluminum Swivel range -55°/+70° 5 m mains supply cable X05RN-F FEP 2 × 1@ + 1G2,5@ with plug-in connector Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit 220-240  50/60 Hz BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components Safety class I
  • Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1-joule c  –

Conformity mark

  • Weight: 1.6 kg This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Total load
When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires. Power consumption of 85 022: 0,07 A\

Lamp

  • Module connected wattage 12 W
  • Luminaire connected wattage 14 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

85 022 K3

  • Module designation LED-1148/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 1730 lm
  • Luminaire luminous flux 1265 lm
  • Luminaire luminous efficiency 90,4 lm / W

85 022 K4

  • Module designation LED-1148/940
  • Color temperature 4000 K
  • Color rendering index CRI > 90
  • Module luminous flux 1815 lm
  • Luminaire luminous flux 1327 lm
  • Luminaire luminous efficiency 94,8 lm / W

Light technique

  • Symmetrical wide beam light distribution Half beam angle 45°
  • The symmetrical light cone can be modified to resemble flat beam light distribution for special lighting applications by replacing the cover glass

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com

Caution
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.

Installation

Press the luminaire with the earth spike vertically into the soil until stability is achieved. If necessary, compact soil around the earth spike. Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug or into the distribution box or extension cable. To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.

Adjustment of beam direction
Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction. Tighten the joint screw.

Please note
Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Cleaning · Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply. Open the floodlight:
  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Replace LED module.
  • Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced. Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop

Accessories

  • 71 279 Shield

  • 71 284 Cylindrical shield

  • 71 289 Exchangeable lens flat beam

  • 0.5 m connecting cable with country-specific mains plugs

  • 71 180 Plug type F / E: system common in Germany and Europe

  • 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)

  • 71 182 Plug type J: system common in Switzerland and Liechtenstein

  • 71 183 Plug type L: system common in Italy and Greece

  • 71 184 Plug type K: system common in Denmark and Greenland

  • 71 186 BEGA UniLink® Extension cable 5 m

  • 71 187 BEGA UniLink® Extension cable 10 m

  • 71 188 BEGA UniLink® Extension cable 20 m

  • 71 247 Connecting cable 5 m with free line ends
    71 256 Connecting cable 0.5 m with free line ends

  • 71 189 BEGA UniLink® Five-way distribution box

For the accessories, a separate instructions for use can be provided upon request

Spares

  • Trim ring graphite with glass 25 000 246
  • LED power supply unit DEV-0136/350
  • LED module 3000 K LED-1148/930
  • LED module 4000 K LED-1148/940
  • Reflector 75 005 131
  • Gasket glass 83 002 169
    Gasket housing 83 002 171

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals