84 855 Performance Floodlight BEGA UniLink Instruction Manual

August 16, 2024
BEGA

84 855 Performance Floodlight BEGA UniLink Instruction Manual

Safety

The installation and operation of this luminaire are subject to national safety regulations.

The manufacturer accepts no liability for damage caused by improper use or installation.

If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.


Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.

To achieve an additional protection against

e. g. transients, etc. we recommend separate overvoltage protection components.

You can find them on our website at

www.bega.com.

Total load

When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.

Power consumption of 84 855: 0,2 A

Lamp

Module connected wattage                        38.4 W
Luminaire connected wattage                       42.5 W
Rated temperature                            ta = 25 °C
Ambient temperature                     ta max = 35 °C84 855 K3

Module designation                           LED-1020/830

Colour temperature                                        3000 K

Colour rendering index                                CRI > 80

Module luminous flux                                    6635 lm

Luminaire luminous flux                               4361 lm Luminaire luminous efficiency             102,6 lm / W

84 855 K4

Module designation                           LED-1020/840

Colour temperature                                        4000 K

Colour rendering index                                CRI > 80

Module luminous flux                                    7005 lm

Luminaire luminous flux                               4604 lm Luminaire luminous efficiency             108,3 lm / W

Lighting technology

Wide beam light distribution

Half beam angle 44°

Caution:

The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage- free state.

Installation

Press the luminaire with earth spike vertically into the soil until stability is achieved. If necessary, compact soil around the earth spike.

Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable.

To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.

Adjustment of beam direction:

Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.

Tighten the joint screw.

Torque = 7 Nm.

Please note:

Do not remove the desiccant bag from the luminaire housing.

It is needed to remove residual moisture.


Cleaning · Maintenance

Clean luminaire regularly with solvent-free

cleansers from dirt and deposits. Do not use high pressure cleaners.

Maintenance

The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.

The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.

The module can be replaced by qualified

persons using standard tools.

Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.

Inspect and, if necessary, replace the luminaire

gaskets.

Defective glass must be replaced.

Close the luminaire.

Tighten grub screws (wrench size 3 mm)

evenly.

Torque = 2.5 Nm.

Accessories

0.5 m connecting cable with country-specificmains plugs 71 180 Plug type F / E: system common in Germany and Europe
71 181 Plug type G: system used in GreatBritain (“Commonwealth plug”)
1 182 Plug type J: system common in Switzerland and Liechtenstein
71 183 Plug type L: system common in Italy and Greece 71 184 Plug type K: system common in Denmark and Greenland 71 186 BEGA UniLink® Extension cable 5 m 71 187 BEGA UniLink® Extension cable 10 m 71 188 BEGA UniLink® Extension cable 20 m

71 247 Connecting cable 5 mwith free line ends 71 256 Connecting cable 0.5 mwith free line ends 71 189 BEGA UniLink® Five-way distributionboxFor the accessories a separate instructions

for use can be provided upon request.

Spares __

Spare glass with frame                            25 000 145
LED power supply unit                         DEV-0131/850
LED module 3000 K                            LED-1020/830
LED module 4000 K                            LED-1020/840
Reflector                                          76 001 459 .A
Gasket                                                             83 001 981

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals