BEGA 84 508 Surface Floodlight Instruction Manual

August 16, 2024
BEGA

BEGA 84 508 Surface Floodlight

Specifications:

  • Lamp Module connected wattage: 9.7 W
  • Luminaire connected wattage: 11.9 W
  • Rated temperature: ta max = 25-40 °C
  • Ambient temperature: ta max = 25-40 °C

Product Information:

The luminaire comes with different module designations, color temperatures, color rendering indexes, luminous flux values, and luminous efficiencies. It is important to follow national safety regulations during installation and operation. Only a qualified electrician should carry out installation and commissioning to avoid any damage due to improper use or installation. Do not remove the desiccant bag from the luminaire housing as it is required to remove residual moisture.

Product Usage Instructions

Safety Precautions:

  1. Installation and operation should comply with national safety regulations.
  2. Installation and commissioning must be done by a qualified electrician.
  3. The manufacturer is not liable for damage caused by improper use or installation.
  4. Do not remove the desiccant bag from the luminaire housing.

Installation:

  1. Ensure the power supply is switched off before installation.
  2. Mount the luminaire securely in the desired location following the manufacturer’s guidelines.
  3. Connect the luminaire to the power supply as per the provided instructions.

Maintenance:

  1. Regularly check for any signs of damage or wear and tear.
  2. Clean the luminaire with a soft, dry cloth to maintain its appearance.

FAQ

  • Q: Can I install the luminaire myself?
    • A: No, installation and commissioning should only be done by a qualified electrician.
  • Q: What should I do if I remove the desiccant bag accidentally?
    • A: Contact the manufacturer for guidance on how to handle the situation.

Dimension

Instructions for use

Application

Floodlight with mounting bush G½. for broad-spread light distribution. The floodlight can be bolted together with any female thread G½ according to ISO 228. The used LED technique offers durability and optimal light output with low power consumption at the same time.

Product Description

  • Luminaire made of aluminum alloy, aluminum, and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector made of pure anodized aluminum
  • The rotation range of floodlight 350°
  • Swivel range -35°/+90°
  • Mounting bracket with G½ threaded connection
  • Thread length: 11 mm
  • Connecting cable H05RN-F 3 G 1@
  • Cable length 1 m
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V 0/50-60 Hz
  • DC 170-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK07
  • Protection against mechanical
  • impacts < 2 joule
  • Safety mark
  • Conformity mark
  • Wind catching area: 0.022 m²
  • Weight: 1.3 kg
  • This product contains light sources of energy efficiency class(es) D

Lighting technology

Half beam angle 80/90° Luminaire data for the DIALux lighting design program for outdoor lighting, street lighting and indoor lighting, as well as luminaire data in EULUMDAT and IES format are available on our website at www.bega.com.

Lamp

  • Module connected wattage 9.7 W
  • Luminaire connected wattage 11.9 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

84 508 K4

  • Module designation LED-0775/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1655 lm
  • Luminaire luminous flux 1184 lm
  • Luminaire luminous efficiency 99,5 lm / W

84 508 K3

  • Module designation LED-0775/930

  • Colour temperature 3000 K
    Colour rendering index CRI > 90

  • Module luminous flux 1565 lm

  • Luminaire luminous flux 1138 lm

  • Luminaire luminous efficiency 95,6 lm / W

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Installation

Screw floodlight mounting bush G½ firmly into the female G½ thread provided on site or into BEGA accessory. Torque of the mounting bush G½ = 20 Nm. Secure bolted connection against loosening. Check earth conductor connection between mounting bush G½ and female thread G½ provided on site. The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable. Adjust the floodlight. Undo the joint screw and adjust the floodlight. Tighten the joint screw.
Torque = 7 Nm.

Cleaning · Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high-pressure cleaners.

Please note:

Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Accessories

  • 70 214 Pole cap for pole top ø 48 mm
  • 70 248 Pole cap for pole top ø 60 mm
  • 70 249 Pole cap for pole top ø 76 mm
  • 70 229 Pole cap for pole top ø 82 mm
  • 70 221 Mounting box for anchorage unit
  • 70 245 Mounting box · rectangular
  • 70 252 General fastener
  • 70 283 Screw clamp
  • 70 379 Cross-beam
  • 70 889 Lashing strap
  • 70 500 Shield
  • For the accessories, separate instructions for use can be provided upon request.

Spares

  • Spare glass 14 000 966
  • LED power supply unit DEV-0141/350
  • LED module 3000 K LED-0775/930
  • LED module 4000 K LED-0775/940
  • Reflector 76 001 194
  • Gasket glass 83 001 372
  • Gasket housing 83 001 386

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals