BEGA 84 216 Performance Floodlight Instruction Manual
- August 16, 2024
- BEGA
Table of Contents
BEGA 84 216 Performance Floodlight
FAQ
- Q: Can I install the luminaire myself?
- A: No, installation and commissioning should only be done by a qualified electrician.
- Q: Where can I find additional overvoltage protection components?
- A: Additional overvoltage protection components can be found on the manufacturer’s website at www.bega.com.
Dimensions
Application
- Performance floodlight with G½ mounting bush.
- The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories.
- For a variety of interior and exterior lighting applications.
Product Description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Clear safety glass
- Silicone gasket
- Reflector surface made of pure aluminium
- Optical silicone lens · BEGA Hybrid Optics®
- Rotation range of floodlight 350°
- Swivel range -30°/+100°
- Mounting bracket with G½ threaded connection
- Thread length: 11 mm
- Connecting cable X05BQ-F 5 G 1 mm²
- Cable length 1 m
- Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit: 220-240 V x 0/50-60 Hz
- DC 176-276 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK08
- Protection against mechanical impacts < 5 joule
- – Safety mark
- CE – Conformity mark
- Wind catching area: 0.02 m²
- Weight: 1.8 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Specifications
Lamp
- Module connected wattage 16.8 W
- Luminaire connected wattage 19 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
84 216 K4
- Module designation LED-0800/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 2480 lm
- Luminaire luminous flux 1937 lm
- Luminaire luminous efficiency 101,9 lm / W
84 216 K3
- Module designation LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 2440 lm
- Luminaire luminous flux 1906 lm
- Luminaire luminous efficiency 100,3 lm / W
Lighting technology
- Symmetrical narrow beam light distribution
- Half beam angle 18°
- For special lighting applications, the symmetrical light cone can be changed to a flat beam using an additional diffuser lens.
Installation
- Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
- G½ threaded connection torque = 40 Nm.
- Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
- Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.
Adjust floodlight:
- Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch B, C).
Torque:
-
Hexagon socket screw = 7 Nm
-
Hexagon nut = 35 Nm
-
Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm).
-
The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
-
Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow ( ), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
-
The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.
Maintenance
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high pressure cleaners.
Please note:
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
Open the floodlight:
- Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
- Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
- Replace LED module.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Place trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other.
- Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
- 71 120 Exchangeable lens flat beam
- 71 118 Shield
- 71 119 Louvre
- 70 214 Pole cap for pole ø 48 mm
- 70 248 Pole cap for pole ø 60 mm
- 70 245 Mounting box
- 70 252 General fastener
- 70 280 Tube clamp G½
- 70 283 Screw clamp
- 70 379 Cross beam G½
- 70 889 Tension belt
It is not possible to use a combination of louvre and diffuser disk.
For the accessories a separate instructions for use can be provided upon
request.
Spares
- Spare glass with frame graphite 25 000 097
- Spare glass with frame silver 25 000 098
- LED power supply unit DEV-0475/500
- LED module 3000 K LED-0800/930
- LED module 4000 K LED-0800/940
- Reflector 76 001 852
- Gasket housing 83 000 521
- Gasket trim ring 83 001 952
Contact
BEGA Gantenbrink-Leuchten KG
- Postfach 31 60 · 58689 Menden
- info@bega.com
- www.bega.com
References