BEGA 84548K4 Performance Floodlight Instruction Manual
- August 28, 2024
- BEGA
Table of Contents
BEGA 84548K4 Performance Floodlight Instruction Manual
Technical amendments reserved
**Performance floodlight
**
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories.
For a variety of interior and exterior lighting applications.
Product description
Luminary made of aluminium alloy, aluminium and stainless steel
BEGA Uninsured® coating technology
Colour graphite or silver Clear safety glass · Silicone gasket
Reflector surface made of pure aluminium
Optical silicone lens · BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+140°
Mounting bracket with G½ threaded connection
Thread length : 11mm
Connecting cable X05BQ-F 5G1mm² Cable length 1m
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V x 0/50-60 Hz DC 176-280 V
During DC operation the LED power is reduced to 15% DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables BEGA Thermal
Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK08
Protection against mechanical impacts < 5 joule
Safety mark
Conformity mark
Wind catching area : 0.05 m²
Weight: 5.4 kg
This product contains light sources of energy efficiency class(es) D
Over voltage protection
The electronic components installed in the luminaire are protected against
over voltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate over voltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage: 71.1 W
Luminary connected wattage: 77.2 W
Rated temperature: ta=25 °C
Ambient temperature: ta max=25 °C
84 548K4
Module designation: LED-0442/940
Colour temperature: 4000 K
Colour rendering index: CRI >90
Module luminous flux: 10710 lm
Luminaire luminous flux : 8270 lm
Luminaire luminous efficiency: 107,1 lm/W
84 548K3
Module designation: LED-0442/930
Colour temperature: 3000 K
Colour rendering index: CRI >90
Module luminous flux: 10550 lm
Luminaire luminous flux: 8146 lm
Luminaire luminous efficiency: 105,5 lm/W
Lighting technology
Symmetrical narrow beam light distribution Half beam angle 27°
For special lighting applications, the symmetrical light cone can be changed
to a flat beam using an additional diffuse lens.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 6 mm) and hexagon nut (wrench size
30 mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 12 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screw (wrench size 2 mm, see sketch B).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow ( ), the phase to the brown (L), and the neutral
conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counterclockwise. Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
71 072; Shield
71 073; Louvre
71 074: Exchangeable lens flat beam
70 214; Pole cap for pole ø 48 mm
70 248; Pole cap for pole ø 60 mm
70 245; Mounting box
70 252: General fastener
70 280: Tube clamp G½
70 283: Screw clamp
70 379: Cross beam G½
70 889: Tension belt
It is not possible to use a combination of louvre and diffuse disk.
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass: 25 000 195
Trim ring silver with glass : 25 000 196
LED power supply unit: DEV-0300/1400i
LED module 3000 K: LED-0442/930
LED module 4000 K : LED-0442/940
Reflector: 76 001 773G
Gasket housing: 83 001 780
Gasket trim ring: 83 002 145
58689 Mennen
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>