MEAN WELL HRP-200 Series 200W Single Output with PFC Function User Guide
- August 16, 2024
- MEAN WELL
Table of Contents
HRP-200 Series 200W Single Output with PFC Function
“`html
Product Specifications
-
Model: HRP-200 series
-
Output Power: 200W
-
Input: Universal AC input / Full range
-
Active PFC Function: PF>0.95
-
Efficiency: Up to 89%
-
Protections: Short circuit, Overload, Over voltage, Over
temperature -
Cooling: Free air convection
-
Low Profile: 1U, 38mm
-
Constant Current Limiting Circuit
-
Remote Sense Function
-
Warranty: 5 years
Product Usage Instructions:
Installation:
-
Ensure the input voltage matches the product
specifications. -
Connect the output terminals to your device following the
correct polarity. -
Ensure proper ventilation around the power supply for effective
cooling.
Operation:
-
Switch on the power supply using the designated power
switch. -
Monitor the LED indicators for any alerts or issues.
-
Avoid overloading the power supply beyond its rated
capacity.
Maintenance:
-
Regularly clean the power supply unit to prevent dust
accumulation. -
Check for any loose connections or abnormal sounds during
operation. -
Refer to the user manual for troubleshooting steps in case of
malfunctions.
Frequently Asked Questions (FAQ):
Q: What is the warranty period for the HRP-200 series?
A: The product comes with a 5-year warranty.
Q: How can I adjust the output voltage of the power
supply?
A: The voltage adjustment range is specified in the manual.
Follow the provided guidelines for adjusting the voltage within the
allowed range.
Q: What should I do in case of a short circuit?
A: The power supply is equipped with short circuit protection.
Disconnect the load and identify the cause of the short circuit
before reconnecting.
“`
200W Single Output with PFC Function
HRP-200 series
GTIN CODE
Features :
User’s Manual
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
1U low profile 38mm
Built-in remote sense function
5 years warranty
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
AS/NZS 62368.1
Bauart gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1 TPTC004
IEC62368-1
MODEL
HRP-200-3.3 HRP-200-5 HRP-200-7.5 HRP-200-12 HRP-200-15 HRP-200-24 HRP-200-36 HRP-200-48
DC VOLTAGE RATED CURRENT CURRENT RANGE
3.3V 40A 0 ~ 40A
5V 35A 0 ~ 35A
7.5V 26.7A 0 ~ 26.7A
12V 16.7A 0 ~ 16.7A
15V 13.4A 0 ~ 13.4A
24V 8.4A 0 ~ 8.4A
36V 5.7A 0 ~ 5.7A
48V 4.3A 0 ~ 4.3A
OUTPUT
RATED POWER
132W
175W
200.3W
200.4W
201W
RIPPLE & NOISE (max.) Note.2 80mVp-p
90mVp-p
100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V
10.2 ~ 13.8V 13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 ±2.0%
±2.0%
±2.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
LOAD REGULATION
±1.5%
±1.0%
±1.0%
±0.5%
±0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
201.6W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5%
205.2W 250mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5%
206.4W 250mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5%
VOLTAGE RANGE Note.5 85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
120 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
INPUT EFFICIENCY (Typ.)
80%
84%
86%
88%
88%
88%
89%
89%
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
2.1A/115VAC 1.1A/230VAC 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC
OVERLOAD PROTECTION
OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V
Protection type : Shut down o/p voltage, re-power on to recover
57.6 ~ 67.2V
OVER TEMPERATURE WORKING TEMP.
Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70 (Refer to “Derating Curve”)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
SAFETY & WITHSTAND VOLTAGE
EMC (Note 4)
ISOLATION RESISTANCE EMC EMISSION
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY MTBF
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020 1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25)
OTHERS NOTE
DIMENSION
1999838mm (LWH)
PACKING
0.77Kg; 18pcs/14.9Kg/0.87CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of
bandwidth by using a 12″ twisted pair-wire terminated with a 0.1F & 47F
parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation
and load regulation. 4. The power supply is considered a component which will
be installed into a final equipment. All the EMC tests are been executed by
mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be
re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power
supplies.” (as available on
https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Derating may be
needed under low input voltages. Please check the derating curve for more
details. 6. The ambient temperature derating of 3.5/1000m with fanless models
and of 5/1000m with fan models for operating altitude higher than
2000m(6500ft).
Product Liability DisclaimerFor detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
File Name:HRP-200-SPEC 2024-01-26
200W Single Output with PFC Function
HRP-200 series
Mechanical Specification
Case No.902E Unit:mm
197
7
9
3.5
3-M3 L=5
3.5 15 26
Terminal Pin No. Assignment
Pin No. Assignment Pin No. Assignment
1
AC/L
4,5 DC OUTPUT -V
2
AC/N
6,7 DC OUTPUT +V
3
FG
Connector Pin No. Assignment (CN100) :
HRS DF11-6DP-2DS or equivalent
Pin No. Assignment Mating Housing Terminal
1
NC
2
NC
3
NC
HRS DF11-6DS HRS DF11-**SC
4
NC
or equivalent or equivalent
5
+S
6
-S
8.2
9.5
9 18.5
1
2
3
4
5
6
7
LED
3.5
CN100
SVR1
4.5
57.5
6.5
13max. 28
80
4-M3 L=5 120
199 190
151
Block Diagram
EMI
I/P
FILTER
FG
ACTIVE INRUSH CURRENT LIMITING
RECTIFIERS &
PFC
O.T.P.
PFC CONTROL
POWER SWITCHING
O.L.P.
PWM CONTROL
RECTIFIERS &
FILTER
DETECTION CIRCUIT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
18 9.5 3.5 28.5 38
PWM fosc :70KHz
+S +V -V -S
85.5
98
LOAD (%) LOAD(%)
112050
100
90
80 80
60
70
60 40
50 20
40
-40
0
10
20
30
40
50
60
70 (HORIZONTAL)
85
100
125
135
155
264
AMBIENT TEMPERATURE ()
INPUT VOLTAGE (V) 60Hz
File Name:HRP-200-SPEC 2024-01-26