MEAN WELL IRM-05 Series 5W AC-DC PCB Mount Green Power Module Owner’s Manual

August 14, 2024
MEAN WELL

MEAN WELL IRM-05 Series 5W AC-DC PCB Mount Green Power Module

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
product

Product Usage Instructions

  1. Installation:
    • Ensure the power module is compatible with your device’s requirements.
    • Mount the module securely on the PCB following proper guidelines.
  2. Connection:
    • Connect the input terminals to a power source within the range of 85~305VAC.
    • Connect the output terminals to your device following polarity markings.
  3. Testing:
    • Before full operation, conduct initial testing to ensure proper functionality.
    • Verify that the no-load power consumption meets specifications.

FAQ

  • Q: What should I do if the power module heats up excessively during operation?
    • A: If the module overheats, immediately disconnect power and allow it to cool before investigating the cause. Ensure proper ventilation during operation.
  • Q: Can I use this power module with devices that have lower input voltage requirements?
    • A: It is recommended to use the power module within the specified input voltage range for optimal performance and safety.

Features

  • 1.8″x1″compact size
  • Universal input 85~305VAC
  • No load power consumption<0.1 W
  • EMI Class B without additional components
  • Wide operating temp. range -30~70°C
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Isolation Class I
  • Pass LPS
  • 3 years warranty

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
fig-2

Applications

  • Industrial electrical equipment
  • Mechanical equipment
  • Factory automation equipment
  • Hand-held electronic device

GTIN CODE

Description

IRM-05 is a 5W miniature (45.725.421.5mm) AC-DC module-type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipments. This product allows the universal input voltage range of 85~305VAC. The 94V-0 flame retardant plastic case and potted with silicone enhance the heat dissipation and meet the anti- vibration demand up to 5G; moreover, it provides the fundamental resistance to dust and moisture.

With the high efficiency up to 77% and the extremely low no-load power consumption below 0.1W, IRM-05 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class Il design (no FG pin), incorporating the built-in EMI filtering components, enabling the compliance with BS EN/EN55032 Class B; the supreme EMC features keep the end electronic units from electromagnetic interference.

Model Encoding

SPECIFICATION

MODEL| IRM-05-3.3| IRM-05-5| IRM-05-12| IRM-05-15| IRM-05-24
---|---|---|---|---|---







OUTPUT

| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V
RATED CURRENT| 1.25A| 1A| 0.42A| 0.33A| 0.23A
CURRENT RANGE| 0 ~ 1.25A| 0 ~ 1A| 0 ~ 0.42A| 0 ~ 0.33A| 0 ~ 0.23A
RATED POWER| 4.125W| 5W| 5.04W| 4.95W| 5.52W
RIPPLE & NOISE (max.) Note.2| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.5%| ±2.5%| ±2.5%| ±2.5%
LINE REGULATION| ±0.3%| ±0.3%| ±0.3%| ±0.3%| ±0.3%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME **Note.4| 600ms, 30ms at full load
HOLD UP TIME (Typ.)**| 80ms/230VAC          15ms/115VAC at full load




INPUT

| VOLTAGE RANGE| 85 ~ 305VAC          120 ~ 430VDC
FREQUENCY RANGE| 47 ~ 440Hz
EFFICIENCY (Typ.)| 68%| 71%| 75%| 75%| 77%
AC CURRENT (Typ.)| 0.12A/115VAC          0.08A/230VAC 0.06A/277VAC
INRUSH CURRENT (Typ.)| COLD START 20A/115VAC          40A/230VAC
LEAKAGE CURRENT| < 0.25mA/277VAC



PROTECTION

| ****

OVERLOAD

| 115% ~ 260% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVER VOLTAGE

| 3.8 ~ 4.95V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode





ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
OPERATING ALTITUDE Note.5| 2000 meters





SAFETY &

EMC

(Note.6)

| SAFETY STANDARDS| IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32), CNS13438| Class B
Radiated| BS EN/EN55032(CISPR32), CNS13438| Class B
Harmonic Current (Note 5)| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-







EMC IMMUNITY

| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, criteria A
Surge| BS EN/EN61000-4-5| Level 3,1KV/L-N, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 9083.9K hrs min.      Telcordia SR-332 (Bellcore) ; 1495.8K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 45.725.421.5 mm (LWH)
PACKING| 0.033Kg;270pcs/  9.8Kg/0.94CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  6. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
    (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

fosc: 65KHz

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
fig-5

Derating Curve

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
fig-6

Output Derating VS Input Voltage

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
fig-7

Mechanical Specification

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
fig-8

Case No.222A Unit:(mm)

More Information

Installation Manual

Please refer to:  http://www.meanwell.com/manual.html

User’s Manual

MEAN-WELL-IRM-05-Series-5W-AC-DC-PCB-Mount-Green-Power-Module-
fig-1

Documents / Resources

| MEAN WELL IRM-05 Series 5W AC-DC PCB Mount Green Power Module [pdf] Owner's Manual
IRM-05 Series 5W AC-DC PCB Mount Green Power Module, IRM-05 Series, 5W AC-DC PCB Mount Green Power Module, PCB Mount Green Power Module, Mount Green Power Module, Green Power Module, Power Module, Module
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals