Specifications
Model| Rated Current| Rated Power| Constant Current Region| Open Circuit
Voltage (max.)
---|---|---|---|---
HVGC-320-700| 700mA| 320W| 214 ~ 428V| 442V
Product Usage Instructions
Installation
Follow the installation guidelines provided in the user manual. Ensure proper
electrical connections and mounting for safe operation.
Adjusting Output Current
For A/AB-Type models, adjust the output current using the built-in
potentiometer within the specified ranges.
Powering On
Connect the LED driver to the power source within the specified voltage range.
Ensure the input connections are secure before turning on the driver.
Driving LED Modules
This LED driver operates in constant current mode to drive LEDs directly.
Ensure compatibility with the end systems to avoid any issues.
Frequently Asked Questions (FAQ)
-
Q: Can the output current be adjusted for all models?
A: The output current adjustment is applicable for A/AB-Type models only via the built-in potentiometer. -
Q: What is the maximum inrush current during cold start?
A: The maximum inrush current during cold start is 50A at 480VAC, as per NEMA 410 standards.
Features
- Wide input range 180 ~ 528VAC
- Constant Current mode output
- Metal housing with Class I design
- Built-in active PFC function • IP67 / IP65 design for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off) ; Smart timer dimming
- Typical lifetime>50000 hours
- 5 years warranty
Applications
- LED street lighting
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- Type “HL” for use in Class I , Division 2 hazardous (Classified) location.
GTIN CODE MW
Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HVGC-320 series is a 320W LED AC/DC LED power supply featuring the constant current mode and high voltage output. HVGC-320 operates from 180~528VAC and offers models with different rated current ranging between 700mA and 3500mA. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40°C ~ +90°C case temperature under free air convection. The design of metal housing and IP67/1P65 ingress protection level allows this series to fit both indoor and outdoor applications. HVGC-320 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encodinal
SPECIFICATION
MODEL| HVGC-320-700| HVGC-320-1050| HVGC-320-1400|
HVGC-320-1750| HVGC-320-2100| HVGC-320-2800| HVGC-320-3500
---|---|---|---|---|---|---|---
OUTPUT| RATED CURRENT| 700mA| 1050mA| 1400mA| 1750mA| 2100mA|
2800mA| 3500mA
RATED POWER| 300W| 320W| 320W| 320W| 320W| 320W| 320W
CONSTANT CURRENT REGION Note.2| 214 ~ 428V| 152.4 ~ 304.8V|
114.3 ~ 228.6V| 91.4~182.8V| 76.2 ~ 152.4V| 57 ~ 114.3V| 45.7 ~ 91.4V
OPEN CIRCUIT VOLTAGE (max.)| 442V| 311V| 234V| 187V| 156V|
118V| 94V
CURRENT ADJ. RANGE| Adjustable for A/AB-Type only (via built-in
potentiometer)
350~700mA| 525~1050mA| 700~1400mA| 875~1750mA| 1050~2100mA| 1400~2800mA|
1750~3500mA
CURRENT RIPPLE| 5.0% max. @rated current
CURRENT TOLERANCE| ±5%
SET UP TIME Note.4| 500ms/230VAC, 347VAC, 480VAC
iNPUT| VOLTAGE RANGE Note.3| 180 ~ 528VAC 254VDC ~
747VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/230VAC, PF≧0.97/277VAC, PF≧0.95/347VAC,
PF≧0.93/480VAC @full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@ load≧50%/230VAC, 277VAC, 347VAC, @ load≧60%/480VAC)
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
EFFICIENCY (Typ.)| 93.5%| 93.5%| 93.5%| 93.5%| 93.5%| 93.5%| 93%
AC CURRENT (Typ.)| 1.1A / 347VAC 0.8A / 480VAC
INRUSH CURRENT(Typ.)| COLD START 50A (width=920μs measured at 50% Ipeak)
at 480VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER| 2 unit(circuit breaker of type
B) / 4 units(circuit breaker of type C) at 480VAC
LEAKAGE CURRENT| <0.75mA / 480VAC
PROTECTION| SHORT CIRCUIT| Constant current limiting, recovers
automatically after fault condition is removed
OVER VOLTAGE| 445 ~ 455V| 320 ~ 351V| 240 ~ 263V| 192 ~ 210V| 160 ~
175V| 120 ~ 131V| 96 ~ 105V
Shut down o/p voltage with re-power on to recovery
OVER TEMPERATURE| Shut down and latch off o/p voltage, re-power on to
recover
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +90℃(Please refer to
“OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS Note.11| UL8750 (type”HL”), CSA
C22.2 No. 250.13-12, IEC/BS EN/EN61347-1,IEC/BS EN/EN61347-2-13, BS EN/EN62384
independent,
EAC TP TC 004, IP65 or IP67 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to FCC Part 15 Subpart B, BS EN/EN55015, BS
EN/EN61000-3-2(@load≧50%), BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line
2KV),EAC TP TC 020
OTHERS| MTBF| 1721.7K hrs min. Telcordia SR-332 (Bellcore) ;
146.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 2629043.8mm (LWH)
PACKING| 2Kg; 8pcs/17Kg/0.92CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 347VAC input, rated current and 25℃ of ambient temperature.
- Please refer to “DRIVING METHODS OF LED MODULE”.
- De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.(as available on https://[www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)](http://www.meanwell.com/Upload/PDF/EMI_statement_en.pdf))
- This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80℃ or less.
- Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com.
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP water proof function installation caution, please refer our user manual before using. https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)
- To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- The models certified by CCC (GB19510.14, GB19510.1, GB/T 17743 and GB17625.1) are optional models. Please contact your MEAN WELL sales for more information.
※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
DRIVING METHODS OF LED MODULE
This series works in constant current mode to directly drive the LEDs.
In the constant current region, the highest voltage at the output of the
driver depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
DIMMING OPERATION
-
in 1 dimming function (for B/AB-Type)
-
Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
~ 10VDC, or 10V PWM signal or resistance. -
Direct connecting to LEDs is suggested. It is not suitable ‧ to be used with additional drivers.
-
Dimming source current from power supply: 100μA (typ.)
Note
- Min. dimming level is about 5% and the output current is not defined when 0%< Iout<5%.
- The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
Smart timer dimming function (for Dxx-Type by User definition)
MEAN WELL Smart timer dimming primarily provides the adaptive proportion
dimming profile for the output constant current level to perform up to 14
consecutive hours. 3 dimming profiles hereunder are defined accounting for the
most frequently seen applications. If other options may be needed,
please contact MEAN WELL for details.
Ex : ◎ D01-Type: the profile recommended for residential lighting
TIME matches Operating Time in the diagram whereas LEVEL matches Dimming
Level.
Example: If a residential lighting application adopts D01-Type, when turning
on the power supply at 6:00pm, for instance:
- The power supply will switch to the constant current level at 100% starting from 6:00pm.
- The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on.
- The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00am, which is 14:00 after the power supply turns on.
Ex: ◎ D02-Type: the profile recommended for street lighting
**: TIME matches Operating
Time in the diagram whereas LEVEL matches Dimming Level.
Example: If a street lighting application adopts D02-Type, when turning on the
power supply at 5:00pm, for instance:
- The power supply will switch to the constant current level at 50% starting from 5:00pm.
- The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on.
- The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on.
- The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on.
- The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming
Level.
Example: If a tunnel lighting application adopts D03-Type, when turning on the
power supply at 4:30pm, for instance:
- The power supply will switch to the constant current level at 70% starting from 4:30pm.
- The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
OUTPUT LOAD vs TEMPERATURE(Note.7)
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACT
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
HVGC-320 series possess superior working efficiency that up to 93.5% can
※ 700mA Model, Tcase at 80℃ be reached in field applications.
LIFE TIME
MECHANICAL SPECIFICATION
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html