RAB SWISHFA-EDGE 2X2 4000K LED Troffer Installation Guide

August 7, 2024
RAB

RAB SWISHFA-EDGE 2X2 4000K LED Troffer

RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-product

Specifications:

  • Model: SWISHFA-EDGE 2X2, SWISHFA-EDGE 2X4
  • Application: Indoor recessed ceiling mounting
  • Power: Factory Settings – 29W (2×2), 39W (2×4)

Product Usage Instructions

Recessed Ceiling Mounting:

The fixture is suitable for indoor recessed ceiling applications. Follow these steps for installation:

  1. Rotate and slide the housing to fit through the Tee-Grid Bar.
  2. Bend the pre-installed Grid Clips against the Tee-Grid Bar to secure the housing.
  3. Support the housing to the building structure using Support Wires through the Support Wire Hole.
  4. Ensure the Access Plate orientation for electrical splices.
  5. Loosen screw on Access Plate, remove it, and knock out appropriate Conduit Knockouts for wiring.
  6. Connect wires as per the wiring diagram, push them back into the Splice Box.
  7. Replace Access Plate, tighten the screw, and remove protective film from the lens after installation.

Power Selection Adjustment:

To change the fixture power from factory settings:

  1. Locate the Power Selection Switch on the side of the Housing Channel.
  2. Select desired power by sliding the switch up or down to the desired value.

FAQ

  • What are the factory power settings for SWISHFA-EDGE fixtures?
    • The factory settings are 29W for SWISHFA-EDGE 2X2 and 39W for SWISHFA-EDGE 2X4.
  • Can the fixture be used in insulated ceilings?
    • The fixture can be mounted in both insulated and non-insulated ceilings by following the provided instructions.
  • How can I control the fixture wirelessly?
    • You can use Lightcloud Blue, a Bluetooth mesh wireless lighting control system, with compatible devices for wireless control.

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

Models

RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(1\)

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

RECESSED CEILING MOUNTING

The fixture is suitable only for INDOOR RECESSED CEILING application. Above ceiling access required.

To mount in an insulated or non-insulated ceiling – 9/16” or 15/16” exposed Flat Tee Grid Ceiling follow the steps below.

  1. Rotate and slide the Housing as required to fit through the Tee-Grid Bar and place it as indicated by the directional arrow as shown in Fig. 1.RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(2\)

  2. Firmly bend the pre-installed Grid Clips (4) against the Tee-Grid Bar to secure the Housing as shown in Fig. 2

  3. Support Wires are required by installation codes. Support the Housing to the building structure by Support Wires (supplied by others) through the Support Wire Hole as shown in Fig. 3.

  4. Make sure that the orientation of the Access Plate faces an accessible tile to make electrical splices.

  5. Loosen screw on Access Plate and remove the Access Plate (Fig. 1). Knock out appropriate Conduit Knockouts on the Access Plate to route input conduit. Use appropriate conduit connectors as required by code.

  6. Connect wires as shown in wiring diagram (Fig 4). Push all wires back into the Splice Box. Be careful not to pinch wires.
    WARNING: To prevent wiring damage or abrasion, do notexpose wiring to edges of sheet metal or other sharp objects.

  7. Replace Access Plate and tighten Access Plate Screw.

  8. After installation remove protective film from the outer surface of the lens.RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(3\)

FIELD ADJUSTMENT

Follow instructions below to change the fixture power from the factory settings. Factory Settings: 29W (2×2) 39W (2×4)

  1. Locate the Power Selection Switch on the side of the Housing Channel as shown in Fig 4.
  2. Select the desired power by sliding the respective Power Selection Switch up or down to the desired value (Fig 5).RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(4\) RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(5\)

LIGHTCLOUD® BLUE

Lightcloud Blue is a Bluetooth mesh wireless lighting control system that allows you to control various compatible devices. With RAB’s patented Rapid Provisioning technology, devices can be quickly and easily commissioned for residential and large commercial applications using the Lightcloud Blue mobile app. Each device in a system can communicate with any other device, eliminating the need for a Gateway or Hub and maximizing the control system’s reach. Lightcloud Blue devices should be placed within the specified range to communicate within the Bluetooh Mesh network. Up to 60 feet between standard building materials. Up to 200 feet clear line of sight. Reset to Factory Settings: To enable pairing or reset the device,locate the device identification button at the top of the Controller under the Lightcloud logo. Press and hold this button for 10 seconds or until the indicator light begins flashing red. and the fixture will also on/off 5 times.

LED Indicators:

  • Blinking Red = Looking for a network
  • Solid Green = Connected to network

RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(6\)

DIMMABLE WIRING

0-10V DIMMABLE WIRING

Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. 0-10V control wires must be rated for 300V minimum.

For 0-10V dimming follow the wiring directions shown in Fig. 7.

  1. Connect the black fixture lead to the LINE supply lead.

  2. Connect the white fixture lead to the COMMON supply lead

  3. Connect the GROUND wire from fixture to supply GROUND. Do
    NOT connect the GROUND of the dimming fixture to the output.

  4. Connect the purple fixture lead to the (V+) DIM lead.

  5. Connect the pink fixture lead to the (V-) DIM lead.

RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(7\)

WIRING

WARNING: Lightcloud Blue-enabled fixtures require constant power and shouldn’t be placed down circuit from any switching devices. Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming, follow the wiring directions shown in (Fig. 8).

  1. Connect the Black fixture lead to the LINE supply lead.
  2. Connect the White fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground.
  4. Connect the Purple wire from fixture to supply ground.
  5. Connect the Pink (Grey) wire from fixture to supply groundRAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(10\)

NOTE: Do not connect DIM V+ (purple)/ DIM V- (pink(grey)) to line voltage or supply ground. To test, double click the Lightcloud Blue button to turn on and off the fixture shown in (Fig. 6) .

CONTROLLING LIGHTCLOUD® BLUE DEVICE

  1. Confirm your device is powered on.
  2. Download the Lightcloud Blue app from the Apple App Store or Google Play store.
  3. Launch the App and create an account or sign into an existing account.
  4. Tap the “add device” icon in the app to start connecting devices.
  5. Follow the remaining steps in the app. Create areas, groups, and scenes to organize and control your devices.
  6. You’re all set!

SENSOR SETUP & INSTALLATION

  1. The PIR Sensor is only compatible with select sensor-ready fixtures. Visit www.rablighting.com to see the full compatibility list.
  2. Remove Bezel: Twist counter-clockwise (Fig. 9).
  3. Prepare Mounting Hole: Use knockout or cut hole for sensor. Holes have +/- 1/8 in. tolerance (Fig. 10).
  4. In-Fixture Mounting: Place gasket and sensor through the hole cut (Fig. 11).
  5. Connect the Sensor Lightcloud Blue Controller: Use the adapter to connect the sensor to the controller.
  6. Plug both RJ09 from Sensor and Controller to adapter

RAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(11\)

SENSOR COVERAGE

CONFIGURATION

To configure the Lightcloud Blue please login to the Lightcloud Blue app for details. For additional startup information, please visit www.lightcloud.com/item/lcb-getting-started/

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch.

Do not clean or maintain while fixture is energized.

  1. Clean polystyrene lens & fixture with non-abrasive cleaning solution.
  2. Do not open fixture to clean the LEDs. Do not touch the LEDs.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?

BATTERY BACKUP MODELS

WIRING

CAUTION: FOR BATTERY BACKUP FIXTURE. Voltage can be present in BATTERY. To prevent high voltage from being present on output leads, Inverter connector must be open. Do not join
BATTERY connector until installation is complete and AC power is supplied to the emergency driver (Fig. 13).
NOTE: Make sure that the necessary branch circuit wiring is available. An UNSWITCHED AC source of power is required. The emergency driver must be fed from the same branch circuit as the LED driver.
CAUTION: Do not use any supply voltage other than 120-277V 50/60 HZ.

  1. Connect UNSWITCHED HOT fixture lead to HOT AC supply line.
  2. If using an UNSWITCHED circuit, connect UNSWITCHED and SWITCHED lines together.
  3. If using a SWITCHED circuit, connect SWITCHED HOT AC fixture lead to the external.
  4. For 0-10V dimming connect DIM (+) purple and DIM (-) pink leads to dimming circuit.
  5. After installation is complete supply AC power to the fixture and connect the BATTERY.
  6. When power is on the fixture should be on and the Charging Indicator Light should illuminate to indicate the battery is charging.
  7. Once the BATTERY has charged for at least one hour a short duration test may be performed by pressing the test button.
  8. After the battery has charged for 24 hours a long duration test can be performed by shutting power to the fixtureRAB-SWISHFA-EDGE-2X2-4000K-LED-Troffer-fig \(13\)

OPERATION

  1. When AC power is applied, the charging indicator light is illuminated, indicating that the BATTERY is being charged.
  2. When power fails the standby power automatically switches to emergency power (internal battery) operating at reduced illumination. The emergency driver supplies standby power for a minimum of 90 minutes.
  3. When AC power is restored, the emergency driver automatically returns to charging mode

MAINTENANCE

Although no routine maintenance is required to keep the emergency driver functional, it should be checked periodically to ensure that it is working. The following schedule is recommended:

  1. Visually inspect the charging indicator light monthly. It should be illuminated.
  2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds.
  3. Conduct a 90-minute discharge test once a year. Fixture would operate at reduced illumination for a minimum of 90 minutes.

TROUBLESHOOTING

  1. Is the fixture grounded properly?
  2. If the charging indicator light does not illuminate after pressing the test button, check if battery is connected properly

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Answers

  • rablighting.com
  • Visit our website for product info
  • Tech Help Line
  • Call our experts: 888 722-1000
  • e-mail Answered promptly – sales@rablighting.com
  • Free Lighting Layouts
  • Answered o © 2024 RAB LIGHTING Inc. online or by request

RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals