JCC JC030005 Commercial Linear Range Installation Guide

August 3, 2024
JCC

JCC JC030005 Commercial Linear Range

Product Specifications:

  • Input Voltage: 220-240V
  • Frequency: 50/60Hz
  • Class: Class I
  • Color Temperatures: WW (3000K), NW (4000K), CW (5700K)
  • Dimming: DALI Dimming
  • Compliance: RoHS Compliant
  • IP Rating: IP20

Product Usage Instructions

Mains Input Connection:

Wire the mains input supply according to the diagram provided. Ensure proper connection of Live permanent, Live switched, Earth, and Neutral wires.

Color Temperature and Power Settings:

Use the selector switch to choose the preferred color temperature (3000K, 4000K, or 5700K) and adjust power settings based on the table provided for non-dimmable and DALI dimming\ variants.

Installation Steps:

  1. Rotate security locks to release end cap (fig.1).
  2. Pull end cap away to access diffuser and remove it (fig.2).
  3. Mark and drill mounting holes in the ceiling.
  4. Feed mains input cable through the base and secure the luminaire to the ceiling.
  5. Connect mains supply and DALI dimming controls as needed.
  6. Reattach the diffuser and secure it in place (fig.3, fig.4, fig.5).
  7. Turn on the power supply and check for correct operation.

Frequently Asked Questions

  • How do I change the color temperature?
    • To change the color temperature, use the selector switch on the product to switch between WW (3000K), NW (4000K), and CW (5700K) options.
  • What should I do before starting the installation?
    • Before starting the installation, make sure to isolate the power supply to prevent any accidents or damage during the process.
  • How do I adjust the power settings for dimmable variants?
    • Refer to the provided tables for non-dimmable and DALI dimming variants to adjust the power settings by adjusting the dip switches accordingly.

WARNINGS AND CAUTIONS

  • To avoid electric shock or serious injury or property damage, isolate power before installing removing or servicing the product
  • It is recommended that this product is installed by an electrician or a competent person with sufficient experience to install this product
  • To be installed in accordance with the local current wiring regulations and standards
  • Any broken or damaged parts should be replaced as soon as possible
  • JCC will not accept responsibility for claims arising from sub-standard installations; which will void the warranty
  • Ensure that you have the tools and accessories required to complete the installation correctly
  • The ambient room temperature should not exceed 25°C
  • This luminaire is suitable for indoor use only: this product is IP20
  • Isolate power before changing Wattage
  • Isolate power before selecting colour temperature

INSTALLATION INSTRUCTIONS

Read instructions and check that you have all of the tools and accessories required to complete the installation correctly. Isolate power supply before starting the installation.

ALWAYS ISOLATE POWER BEFORE CHANGING COLOUR TEMPERATURE OR WATTAGE

SELECT THE PREFERRED CCT BY USING THE SELECTOR SWITCH

SELECT PREFERRED POWER SETTING USING THE TABLES BELOW

  1. Rotate the two security locks on the one end of the fitting to release the end cap shown in fig. 1.
  2. The end caps are sprung loaded, pull the end cap away from the body to access the diffuser. Once you can access the diffuser lift up and out of the fitting by pulling out of the opposite end cap as shown in fig.2.
  3. Using the main body as a template mark and drill mounting holes in the ceiling in a suitable location.
  4. Feed mains input cable through cable entry on the base of the unit. Secure luminaire to the ceiling and terminate the mains supply for standard or emergency version as indicated to the left and connect DALI dimming controls where required.
  5. Refit the diffuser by sliding the end of inside of the locked end cap as shown in fig.3.
  6. Pull the unlocked end cap away from the body and lay the diffuser into the body, release the end cap to secure the diffuser as shown in fig.4.
  7. Rotate the the security locks to secure the end cap in place shown in fig.5.
  8. Turn on power supply and check for correct operation.

Microwave On/Off operation and settings

  • Up to 6m
  • Up to 4.5m
  • Up to 3m
  • Up to 1.5m

Detection Area

Sensor data can be set using DIP switches on the sensor. The settings are as follows:

Hold Time

Refers to the time period the lamp remains at 100% illumination after no motion detected.

Daylight Sensor

  1. 2lux
    (darkness operation only)

  2. 10lux
    (darkness operation only)

  3. 25lux
    (twilight operation only)

  4. 50lux
    (twilight operation only)

  5. Disable*

The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold.
*When set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light level.

Profile & Dimensions

All dimensions in millimeters

Override function

Quick switch ON/OFF 3 times within 2sec to override sensor function. Lights will switch on all the time. Power off and on again to recover sensor function.

Commissioning

After powering on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light.
During the initialization, the sensor is not able to detect movement.

Factory settings

Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable

You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate waste disposal centre. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service.

BS EN IS09001 – 2015 – Registered Firm Certificate No. GB 1552 JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT

  • Technical Support+44(0)1243 838986
  • Customer Services: +44(0)1243 838999

Note:

Lumens and LpcW stated below is for products set to 4000K CCT

QUICK REFERENCE GUIDE

Emergency range routine inspection and test

All tests must be undertaken at times of least risk and in accordance with EN 50172:2004 as indicated below:

  • Daily: Indicators of central power supply shall be visually inspected for correct operation.
  • Monthly: (nort duration tests shall be recorded. test shall carried out as followe se suits of the
  • a) Switch the luminaire over to emergency mode to operate from the batteries by simulating a failure of supply to the normal lighting for a period sufficient to ensure correct luminaire operation

NOTE: The period of simulation failure should be sufficient for the purpose of this clause whilst minimizing damage to the ensure that they are present, clean and functioning correctly. At the end of this test period, the supply to the normal lighting should be restored and any indicator lamp or device should be checked to ensure that is shows that the normal supply has been restored Annually: If automatic testing devices are used, the results of the short duration tests shall be recorded. ‘

For all other systems, the monthly inspection shall be carried out and the following additional tests made:

  • a) Es full curation indicordal With the manufacture enter atinhly as above but for
  • b) The normal supply for the luminaire should be restored and any charge indicator lamp re device should be checked to ensure that it shows the normal supply has been The charging arrangements should be checked for proper functioning.
  • c) The date of the test and its results shall be recorded in the system logbook. A copy of this report must accompany any fitting returned to the manufacturer for any reason.

General Information

Our products are designed to comply with the requirements of UK law and the relevant industry national and international standards and should not be modified in any way. All emergency lighting systems should comply with the recommendations of BS5266-1: Code of Practice for the Emergency Lighting of Premises and be installed by competent engineers in accordance with the relevant wiring regulations. Before installing any type of Emergency Lighting always seek the advice and approval of the local Fire Prevention Officer (or equivalent authority).

Maintenance

Failed or faulty light sources connected to this equipment should be replaced immediately. These units are designed especially for a long and trouble free life. Under normal conditions, will require no routine maintenance or service beyond the inspection and test regime of BS5266-1. Both mains supply and battery protection fusing is incorporated internally. Should access to these or any other part of the circuitry be required this must be undertaken only by suitably qualified person. Special care must be taken when removing the cover to circuitry and battery. Only replacement components authorised by the company must be used. Disposal of replaced components should be in accordance with the component manufacturers instructions.

Emergency Charge Indicator

Important warranty information

The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chassis: Product Code/Date Code.

BS EN IS09001 – 2015 – Registered Firm Certificate No. GB 1552 JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, P020 2FT

  • Technical Support: +44(0)1243 838986
  • Customer Services: +44(0)1243 838999

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals