JCC JC72501 Skydisc IP65 Range LED Commercial Downlights Instruction Manual

June 12, 2024
JCC

JCC JC72501 Skydisc IP65 Range LED Commercial Downlights

SkydiscTM IP65 Range
The SkydiscTM IP65 Range is a series of LED commercial downlights designed for installation in various indoor environments. These downlights are suitable for both residential and commercial settings.
Warnings & Cautions

  • Before installing, removing, or servicing the product, please ensure that you have read and understood the installation instructions.
  • Consult a qualified electrician to ensure that the installation complies with local wiring regulations and safety standards.
  • Make sure to isolate the power supply before starting the installation.
  • Using sub-standard installation methods may void the warranty, and the manufacturer will not accept responsibility for any resulting claims.

Installation
Product Specifications

Code Wattage Color Temperature Lumens LpcW
JC72501 7W 4000K 650 93
JC72502 13W 4000K 1300 100
JC72503 17W 4000K 1700 100
JC72504 23W 4000K 2100 91
JC72505 7W 4700K 650 93
JC72506 13W 4700K 1300 100
JC72507 17W 4700K 1700 100
JC72508 23W 4700K 2100 91
JC73505 7W 5700K 650 93
JC73506 13W 5700K 1300 100
JC73507 17W 5700K 1700 100
JC73508 23W 5700K 2100 91

Installation Procedure

  1. Cut the mounting hole in the ceiling. JCC recommends practicing on a spare material first to familiarize yourself with the process.
  2. Ensure there is a minimum of 75mm space around the fitting. Do not cover the fitting with insulation.
  3. Connect the mains supply to the luminaire driver as instructed.
  4. Turn on the power supply to test the fitting. Once satisfied, press the spring clips against the side of the luminaire and fit it into the aperture.

Notes

  • Do not partially install the luminaire, as this can cause damage to the fitting.
  • Refer to the specific cut-out size for each product variant.

Emergency Version Conversion
If you wish to convert to an emergency version using JCEM002/JCEM002ST, follow these steps:

  1. Remove the green cover on the DC side of the driver to access DC connectors.
  2. Connect the emergency components.
  3. Replace connectors inside the driver and refit the cover.

Environmental Considerations
Please respect local regulations for disposing of non-working electrical equipment. Hand them in at an appropriate waste disposal center. The packaging material is recyclable, so dispose of it in an environmentally friendly manner and make it available for recyclable material collection services.

Warranty Information
This product is supported by a 2-year standard warranty, which can be extended to 3 years by registering within the first year of purchase. To register, visit jcc.co.uk/warranty. Terms and conditions apply.

Contact Information

  • Technical Support: +44(0)1243 838986
  • Customer Services: +44(0)1243 838999

Company Information

JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FTBS EN ISO9001 – 2015 – Registered Firm Certificate No. GB 1552 Website: www.jcc.co.uk

Warnings & Cautions

  • To avoid electric shock, serious injury or property damage, isolate power before installing, removing or servicing the product.
  • It is recommended that luminaires are installed by a qualified electrician to ensure the installation complies with the local current wiring regulations.
  • Any broken or damaged parts should be replaced as soon as possible. JCC will not accept responsibility for claims arising from sub-standard installations; which will void the warranty.
  • It may be necessary to upgrade your MCBs to allow for increased inrush current.
  • This product is suitable for indoor use only
  • Read the instructions and check that you have all of the tools and accessories required to complete the installation correctly. Isolate the power supply before starting installation.
  • This product is designed for connection to a 220-240V~ 50/60Hz.

INSTALLATION

  • 220-240V~ 50/60Hz / Class II
  • LIVE = BROWN
  • NEUTRAL = BLUE

Double insulated- no earth required

Code Wattage Colour Temperature Lumens LpcW
JC72501 7W 4000K 650 93
JC72502 13W 4000K 1300 100
JC72503 17W 4000K 1700 100
JC72504 23W 4000K 2100 91
JC72505 7W 4700K 650 93
JC72506 13W 4700K 1300 100
JC72507 17W 4700K 1700 100
JC72508 23W 4700K 2100 91
JC73505 7W 5700K 650 93
JC73506 13W 5700K 1300 100
JC73507 17W 5700K 1700 100
JC73508 23W 5700K 2100 91
Skydisc™IP65 Driver output VDC Cut out size
--- --- ---
7W 57.75-63 VDC Ø100mm-110mm
13W 50.4-59.4VDC Ø150mm-160mm
17W 67.2-79.2VDC Ø200mm-210mm
23W 75.6-89.1VDC Ø220mm-230mm

Installation procedure

  1. Cut the mounting hole in the ceiling (refer to Fig.1). (JCC recommends that a sample hole is cut in a section of spare material to familiarize yourself with the process).
  2. Ensure there is a minimum of 75mm space around the fitting. DO NOT COVER the fitting with insulation as indicated by this symbol on the luminaire.
  3. Connect the mains supply to the luminaire driver as above.
  4. Turn on the power supply to test the fitting. Once satisfied that the luminaire is functioning correctly, press the spring clips against the side of the luminaire and fit into the aperture.

Note: when fitting the luminaire do not partially install as shown below as this can cause damage to the fitting ie. if decorating.

PLEASE NOTE
When converting to an emergency version using JCEM002/JCEM002ST, to access DC connectors remove the green cover on the DC side of the driver. Once connected, replace the connectors inside the driver and refit the cover.

You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate waste disposal center. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service.

Profile & Dimensions

JCC-JC72501-Skydisc-IP65-Range-LED-Commercial-Downlights-fig-
\(4\)

Important warranty information
This product is supported by a 2-year standard warranty which will extend to 3 years if registered within the first year of purchase. Please register at jcc.co.uk/warranty – Terms and conditions apply.
The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chassis: Product Code/Date Code. BS EN ISO9001 – 2015 – Registered Firm Certificate No. GB 1552 JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals