JCC JC71553WOP Series ToughLED Range Light Instruction Manual

June 10, 2024
JCC

JCC JC71553WOP Series ToughLED Range Light Instruction Manual
JCC JC71553WOP Series ToughLED Range Light

Warnings and cautions

  • To avoid electric shock or serious injury or property damage, isolate power before installing, removing or servicing the product
  • It is recommended that this product is installed by an electrician or a competent person with sufficient experience to install this product.
  • To be installed in accordance with the local current wiring regulations and standards.
  • Any broken or damaged parts should be replaced as soon as possible.
  • JCC will not accept responsibility for claims arising from sub-standard installations; which will void the warranty
  • Ensure that you have the tools and accessories required to complete the installation correctly
  • The ambient room temperature should not exceed 25°C
  • This luminaire is suitable for indoor or outdoor use: this product is IP65
  • Emergency product routine inspection and tests must be undertaken at times of least risk and in accordance with EN 50172:2004.
  • For emergency versions, the green indicator light is on for correct operation and off indicates a fault
  • Battery life is 2 years, but must be replaced if fails test in accordance with EN 50172:2004

INSTALLATION

  1. Mark and drill mounting holes for the snap-in ceiling clips at the correct spacing for the version being installed.
  2. Affix clips securely to ceiling.
  3. Clip the luminaire into place and ensure that it is secure before proceeding.
  4. To gain access to the interior of the luminaire release the clips that secure the diffuser to the base section.
  5. Separate the LED plate from the base by squeezing the securing clips inwards and pulling the plate away from the base There are permanent restraints that prevent the plate from falling during installation and servicing.
  6. Wire the mains input supply to the terminal block as per the diagram shown below: Live, earth and neutral for standard versions and Switched live(L), Unswitched live(L1),earth and neutral for emergency versions
  7. Connect required dimming control where appropriate
  8. Connect batteries to commission for emergency versions
  9. Refit LED plate, diffuser and diffuser clips. For additional security locking screws are provided for clips.
  10. Power up fitting to ensure that it is functioning correctly.
  11. Allow 24hrs minimum charge for batteries on emergency versions before testing.
  12. To change operation mode to test, isolate the mains power. This will switch the product into emergency mode. Once test is completed reconnect the mains power. Check indicator light is on for correct operation.

Standard Version Connection

Figure 1. 220-240V~ 50/60Hz / Class I

N = neutral
= earth
L = Live

Emergency Version Connection

Figure 2. 220-240V~ 50/60Hz / Class I

L1 = Unswitched live
L = Switched Live
= earth
N = neutra

Dimming control connections
Dimming control connections

Fixing brackets

Single

Twin

Fixing centres

Single

**Twin

Fixing bracketsFixing
centres
** Specifications

Colour temp: 4000K
Ra: 80
Beam Angle: 120°

Model Wattage Lumen lpcW
JC71553WOP 18W 2050 114
JC71553EM/WOP 18W 2050 114
JC71553FR 18W 2300 128
JC71553EM/FR 18W 2300 128
JC71554WOP 37W 4300 116
JC71554EM/WOP 37W 4300 116
JC71554FR 37W 4700 127
JC71554EM/FR 37W 4700 127
JC71555WOP 27W 3200 119
JC71555EM/WOP 27W 3200 119
JC71555FR 27W 3400 126
JC71555EM/FR 27W 3400 126
JC71556WOP 57W 6150 108
JC71556EM/WOP 57W 6150 108
JC71556FR 57W 7000 123
JC71556EM/FR 57W 7000 123
JC71557WOP 35W 3800 109
JC71557EM/WOP 35W 3800 109
JC71557FR 35W 4300 123
JC71557EM/FR 35W 4300 123
JC71558WOP 70W 7100 101
JC71558EM/WOP 70W 7100 101
JC71558FR 70W 8600 123
JC71558EM/FR 70W 8600 123

Available diffuser options: White Opal(WOP) or Frosted(FR). Dimmable or microwave versions also available. Add “DALI” or “/1-10V” or ‘MW’ to the end of the product number for dimmable or microwave versions: e.g ‘JC71553MW/FR’ or ‘JC71553FRDALI’ or ‘JC71553WOP/1-10V’

You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate waste disposal centre. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service

Symbols
IP65 jcc.co.uk V15_Sept_2022_RS

Profile & Dimensions

JC71553
Profile & Dimensions

JC71554
Profile & Dimensions

JC71555
Profile & Dimensions

JC71556
Profile & Dimensions

JC71557
Profile & Dimensions

JC71558
Profile & Dimensions

Important warranty information

This product is supported by a 2-year standard warranty which will extend to 5-years if registered within the first year of purchase. Please register at jcc.co.uk/warranty (Terms and conditions apply).

The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chassis: Product Code/Date Code.

Emergency Range Routine Inspection & Test 

All tests must be undertaken at times of least risk and in accordance with EN 50172:2004 as indicated below:

Daily: Indicators of central power supply shall be visually inspected for correct operation.

Monthly: (in addition to the daily check) If automatic testing devices are used, the results of the short duration tests shall be recorded. Test shall be carried out as follows:

a) Switch the luminaire over to emergency mode to operate from the batteries  bysimulating a failure of supply to the normal lighting for a period sufficient to ensure correct luminaire operation

NOTE: The period of simulation failure should be sufficient for the purpose of this  clause whilst minimising damage to the system components e.g lamps. During this period, all luminaires and signs shall be checked to ensure that they are present, clean and functioning correctly.
At the end of this test period, the supply to the normal lighting should be restored and any indicator lamp or device should be checked ensure that is showing that the normal supply has been restored.

Annually: If automatic testing devices are used, the results of the short duration tests shall be recorded.
For all other systems the monthly inspection shall be carried out and the following additional tests made:

a) Each luminaire and internally illuminated sign shall be tested monthly as above but for its full duration in accordance with the manufacturer’s information.
b) The normal supply for the luminaire should be restored and any charge indicator lamp or device should be checked to ensure that it shows the normal supply has been restored.The charging arrangements should be checked for proper functioning.
c) The date of the test and its results shall be recorded in the system logbook.

A copy of this report must accompany any fitting returned to the manufacturer for any reason.

General Information

Our products are designed to comply with the requirements of UK law and the relevant industry national and international standards and should not be modified in any way. All emergency lighting systems should comply with the recommendations of BS5266-1: Code of Practice for the Emergency Lighting of Premises and be installed by competent engineers in accordance with the relevant wiring regulations. Before installing any type of Emergency Lighting always seek the advice and approval of the local Fire Prevention Officer (or equivalent authority).

Maintenance

Failed or faulty light sources connected to this equipment should be replaced immediately. These units are designed especially for a long and trouble free life. Under normal conditions, will require no routine maintenance or service beyond the inspection and test regime of BS5266-1.

Both mains supply and battery protection fusing is incorporated internally. Should access to these or any other part of the circuitry be required this must be undertaken only by suitably qualified person. Special care must be taken when removing the cover to circuitry and battery. Only replacement components authorised by the company must be used. Disposal of replaced components should be in accordance with the component manufacturers instructions.

Emergency Test Record Table

Month Test Type First Year Second Year Third Year Fourth Year Fifth Year
Sign Date Sign Date Sign Date Sign
January Functional
February Functional
March Functional
April Functional
May Functional
June Functional
July Functional
August Functional
September Functional
October Functional
November Functional
December 3 hour

BS EN ISO9001 – 2015 – Registered Firm Certificate No. GB 1552
JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT
Technical Support: +44(0)1243 838986
Customer Services: +44(0)1243 838999

Jcc logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JCC User Manuals

Related Manuals