General Description

WI400-12 and WI400-24 are DC / AC inverter, designed for off-grid applications, with high reliability and professional performance.

The product was developed to produce a waveform of pure sine AC output, with high conversion efficiency, up to 90%, and very low power consumption in stand-by mode, less than 2.5W.

These features are obtained through a hybrid configuration with toroidal transformer output and high frequency switching technology. (HF Technology)

The energy saving function allows to reduce the consumption in a significant way in the event of lack of the connected load, ensuring a superior system autonomy.

| AC pure sine wave output
---|---
| Continuous power 400 VA
Output voltage: 230V 50Hz
| Maximum inverter efficiency 90%
| Energy Saving Function
| Shutdown switch
| LED indications
| Battery voltage 12 or 24Vdc
| Sealed, liquid acid or lithium batteries
| IP20 housing
| Protections:

  • Low battery
  • Short circuit and AC overload
  • Over-temperature
    Symbols

WI400-12 AND WI400-24 INSTALLATION GUIDE

  1. BATTERY CABLES: the WI400-12 and WI400-24 inverters have to be connected to the battery with cables with a suitable section, in particular in the case of distance between the inverter and battery less to 1.5m or more but in any case within 3m, according to the following table;

  2. BATTERY CONNECTION: configure your battery bank with voltage 12V for WI400-12 model, battery bank 24V voltage for the WI400-24 model, then connect the RED terminal to the POSITIVE of the battery and the BLACK terminal to the NEGATIVE of the battery; (WARNING: if you do not respect the polarity the inverter will be damaged permanently!)

  3. AC CONNECTION: Connect the AC load user with 230Vac output, through SCHUKO standard connection; (CAUTION: Never connect the output of the inverter to another AC source, such as the electricity grid or a generator!)

  4. POWER ON of the INVERTER : set the power switch I-0-II in position I [ON], perform the startup of the inverter and check the power supply of the user load; (WARNING: in case of overload for 3 times within 30 seconds, the inverter goes into automatic shutdown, for the restart is necessary to turn off the power switch, remove the cause of overload and provide with a new power on procedure!)

  5. POWER ON of the INVERTER in ENERGY SAVING MODE: set the power I-0-II position II [ECO] switch, the power saving feature enables a reduction in power consumption in stand-by 70%, through the activation of the inverter for a short period every 2.5 seconds. The inverter switches to an activation status always ON for a load with more than 30W while turns into a energy saving status for a load with less than 20W;
    Wi400-12 And Wi400-24 Installation Guide

  6. RENEWABLE PLANT: if there is a plant of renewable energy production, connect the plant through a dedicated charge controller on the battery terminals. (WARNING: WI400 inverter battery cables should always be connected directly to the battery terminals!)

  7. REMOTE ON / OFF: connect a remote on/off power switch to the dedicated connector with 2 poles removing the series closure jumper. (CAUTION: even the power switch must be set to ON or ENERGY SAVING)

MEANINGS OF LED INDICATIONS

Table of LED STATUS and LED ERROR warnings

LED STATUS

| GREEN LED ON: normal working status activated ON.

LED STATUS

| SLOW FLASHING GREEN LED: working status at energy saving ON.

ED STATUS + WARNING

| GREEN LED ON RED ON: forthcoming shutdown due to OVERLOAD.

ED STATUS + WARNING

| GREEN LED ON RED SLOW FLASHING: forthcoming shutdown due to LOW BATTERY.

ED STATUS + WARNING

| GREEN LED ON RED DOUBLE FLASHING: forthcoming shutdown due to OVER- TEMPERATURE.

LED ERROR

| GREEN LED OFF RED ON: inverter shutdown due to OVERLOAD.

LED ERROR

| GREEN LED ON RED SLOW FLASHING: forthcoming shutdown due to LOW BATTERY.

LED ERROR

| GREEN LED ON RED DOUBLE FLASHING: forthcoming shutdown due to OVER- TEMPERATURE.

LED ERROR

| GREEN LED OFF FAST FLASHING RED: inverter shutdown due to OVER-VOLTAGE BATTERY.

WARNING: in case of LOCKED inverter, there is no supply voltage at the output AC-OUT, because occurred of one of the FOUR fault conditions specified in tab. 3, you need to RESTART the device, according to the following sequence:

  1. turning off with switch in position 0 [OFF]
  2. wait for 2 seconds
  3. new turning on with the switch in position I [ON] or II [ECO]

WIRING SCHEME

Wiring Scheme

MECHANICAL FEATURES

Mechanical Features

ELECTRICAL FEATURES

| | | WI400-12| WI400-24
---|---|---|---|---
| | | Min| Type| Max| Min| Type| Max
INVERTER| Output power| Pout| –| 400VA| 700W| –| 400VA| 400W
Battery voltage| Vbatt| 9.2V| 12V| 17V| 18.4V| 24V| 34V
Output voltage| Vac| –| 230V| –| –| 230V| –
Output frequency| Fac| –| 50hz

± 0.1%

| –| –| 50hz

± 0.1%

| –
Efficiency| Eff| –| 90%| –| –| 90%| –
Internal consumption in standby mode| Psb| –| 2.5W| –| –| 2.5W| –
Load activation / energy saving| Pes| –| 30W / 20W| –| –| 30W / 20W| –
Threshold alert for low battery| Tba| 10.8V| 10.9V| 11.0V| 21.6V| 21.8V| 22.0V
Shutdown threshold for low battery| Tbs| –| 9.3V| –| –| 18.6V| –
Reactivation                threshold from low battery| Tbr| –| 10.9V| –| –| 21.8V| –
Internal over temperature alarm| Tot| | 55°C| | | 55°C|
Operating temperature| Tamb| -10°C| 45° C| 70°C| -10°C| 40°C| 70°C
| | | Min| Type| Max| Min| Type| Max
Enclosure| Section battery terminals| | –| 10mm2| –| –| 10mm2| –
AC connection| | –| Schuko (CEE 7/4)| –| –| Schuko (CEE 7/4)| –
Protection degree| | | IP21| | | IP21|
Dimensions| | 230x130x85 mm| 230x130x85 mm
Weight| | –| 3.5 Kg| –| –| 3.5 Kg| –

Tab.2 ELECTRICAL FEATURES

WARRANTY

Western CO. Srl guarantees the good quality and good design of its own Products obliging itself, during the warranty period of 5 (five) years, to repair or replace at its sole discretion, for free, those defective parts owing to poor quality of material or defect in workmanship.
The defective product must be returned to Western Co. Srl or to the company delegated by Western Co to make product support, at customer’s expenses, together with a copy of the invoice both for repairing and warranty replacement. The costs of re-installation of the equipment will be borne by the customer. Western CO. Srl will bear the transport expenses of the repaired or replaced product.

The warranty does not cover Products that, according to our discretion, are defective due to natural wear, showing damages caused by incompetence or negligence of the customer, imperfect installation, by tampering or other interventions different by the instructions supplied by us.

The warranty is not valid also in case of damages coming from: – transport and/or incorrect storage of the product. force majeure or catastrophic events (frost to temperatures below -20° C, fire, flood, lightning, vandalism, and so on).

All of the above mentioned guarantees are the sole and exclusive agreement which supersedes any proposal or agreement, oral or written, and any other communication made between the manufacturer and the purchaser in respect of the above.
For any dispute the jurisdiction is Ascoli Piceno.

WASTE DISPOSAL

Western CO. as manufacturer of the electrical device herein described and in accordance with DL 07/25/2005 n 151, informs the consumer that this product, once abandoned, must be delivered to an authorized collection centre or, in case of purchase of an equivalent equipment, it can be returned free of charge to the distributor of the new equipment.
The penalties will be applied by individual Municipalities.

This document is the property of WESTERN CO. Srl – All rights are reserved – Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO. Srl.

Scan the QR CODE placed on the side of the product or visitwww.western.it to download the latest manual version.
Symbols

CUSTOMERS SUPPORT

WESTERN CO. Srl.
Via Pasubio, 1
63074 San Benedetto del Tronto (AP)
Tel. (+39) 0735 751248 fax. (+39) 0735 751254
e-mail: info@western.it
web: www.western.it

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Western User Manuals

Related Manuals