Q-TRAN QOM-eLED+DMX LED Power Supply Installation Guide
- June 8, 2024
- Q-TRAN
Table of Contents
Q-TRAN QOM-eLED+DMX LED Power Supply
INSTALLATION
-
Must be installed by licensed electrician.
-
Installation must be in accordance with DMX512-A standard
-
DMX Shield must be grounded to Earth Ground at a single point external to power supply
-
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
-
This power supply must be installed according to the National Electric
-
Code and local codes and ordinances.
-
This power supply is to be installed and serviced only by an licensed electricians.
-
This power supply is to be installed so that it is not likely to be contacted by people.
-
To avoid a hazard to children, account for all parts and destroy all packaging materials.
Housing
- ISOMETRIC VIEW
- BOTTOM VIEW
Mounting Options
NOTE: To order additional lengths of wire for connection in the secondary
Please call factory for availability. : QOM must be installed as
shown.
Connecting and Configuring the LINEAR drive 100D/180D
Primary Wiring
How can I verify my installation?
- Apply AC input, verify display turns on : This confirms AC input wiring
- Run “Visual Test Run” : This verifies wiring of LEDs. Make sure LEDs turning on go in same order as the Test Run
I don’t have a controller yet, how can I keep my lights on?
- Change the Mode to “COLOR” : This allows to manually set a specific color to be on
- Adjust the Hue or WHITE to achieve the desired color : This sets that specific color
My LEDs aren’t coming out the right color. They look like white has been added in
- Verify the Network Resolution “NETW RES” : Default is 8 BT
- Check your DMX Programming. Stick controllers come with RGB programs by default. This will cause RGBW LEDs to show Pink vs. Red
Secondary Wiring
Control Wiring
DMX Connections
WARNING: Risk of electrical shock. May result in serious injury or death.
Disconnect power before servicing or installing.
CAUTION: The device may only be connected and installed by a qualified
electrician. All applicable regulations, legislation and building codes must
be observed.
Incorrect installation of the device can cause irreparable damage to the
device and the connected LEDs.
DMX Shield must be grounded to Earth Ground at a single point external to
power supply
Manual Configuration
- Select mode of operation:
- Set LED groups:
- Standalone operation Colour Standalone operation Show
Networked operation DMX
The colour menu depends on the LED group settings you have selected in step 2.
Other Features
-
Visual test run
-
Locking the configuration:
-
Reset to factory defaults
Wiring Installation
CSA Requirements
- Suitable for indoor and outdoor use
- This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
- This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
- To avoid a hazard to children, account for all parts and destroy all packaging materials.
- DMX shield wire must be grounded to earth ground at a single point external to power supply.
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com