GRANDSTREAM HT841 Analog VoIP Gateway Installation Guide

July 31, 2024
GRANDSTREAM

HT841 Analog VoIP Gateway

“`html

Specifications

  • Model: HT841/HT881
  • Ports: NET1, NET2, PoE supported, FXS, FXO
  • Factory Reset Button: Yes

Product Usage Instructions

Ports Description

  • Network NET2 port: Connects the HT841/881 to
    your PC or switch using an Ethernet RJ45 network cable.

  • Network NET1 port: Connects the HT841/881 to
    your router or switch using an Ethernet RJ45 network cable.

  • PoE supported port.

  • FXS port: Connect analog phone/fax machine to
    HT841/HT881 using RJ11 telephone cable.

  • FXO ports: Connect to physical PSTN line from
    a traditional PSTN PBX or PSTN Central Office.

Connecting the HT841/HT881

Using NET 1 port:

  1. Insert RJ11 telephone cable into FXS port.

  2. Connect NET 1 port to router/switch/modem using Ethernet
    cable.

  3. Plug in power adapter and connect to wall outlet.

  4. Check for solid LEDs indicating readiness.

Using NET 2 Port:

  1. Insert RJ11 telephone cable into FXS port.

  2. Connect computer/switch to NET 2 port using Ethernet
    Cable.

  3. Plug in power adapter and connect to wall outlet.

  4. Check for solid LEDs indicating readiness.

Configuring the HT841/HT881

Configure via IVR Menu:

  1. Use analog telephone connected to FXS port.
  2. Press *** to access the IVR menu.
  3. Follow IVR Menu options to configure your HT841/HT881.

FAQ

Q: How do I reset the HT841/HT881 to factory default

settings?

A: Press the factory reset button for 7
seconds. A quick press will only reboot the unit.

“`

6/25/24, 11:30 AM

HT841/HT881 – Quick Installation Guide – Documentation Center

Documentation Center

Home Knowledge Base Unified Communication Solution Gateways & ATAs HT841/HT881 Installation HT841/HT881 – Quick Installation Guide Search here..

HT841/HT881 – Quick Installation Guide
OVERVIEW
The HT841/HT881 Analog VoiP Gateway series is an easy to set up IP communications solution that is suitable for small enterprises, as well as those with virtual and branch locations, who wish to bene t from their broadband network or integrate new IP technology with their existing phone system. This series of enterprise analog VoIP gateway can con-vert SIP/RTP IP calls into conventional PSTN calls, and it is available in two models, the HT841 and HT881, with 4 and 8 FXO ports, respec-tively. Both models share the same installation process.
Precautions:
Do not attempt to open, disassemble, or modify the device. Do not use a third party power adapter. Do not expose this device to temperatures outside range of 0 °C to +40 °C (in operation) and -10 °C to +60 °C (in storage). Do not expose the HT841/HT881 to environments outside of the fol-lowing humidity range: 10-90% RH (non-condensing). Do NOT power cycle the HT841/HT881 during system boot up or rm-ware upgrade. You may corrupt rmware images and cause the unit to malfunction.

PACKAGE CONTENTS

Package Content

HT841/HT881 – Quick Installation Guide

1/5

6/25/24, 11:30 AM
HT841/HT881 PORTS

HT841/HT881 – Quick Installation Guide – Documentation Center

HT841/HT881 Ports

Port

Description

Power socket. Used to power HT841/HT881 (12V ­ 0.5A)

Network NET2 port. Connects the HT841/881 to your PC or switch using an Ethernet RJ45 network cable.

Network NET1 port. Connects the HT841/881 to your router or switch using an Ethernet RJ45 network cable.

PoE supported port.

FXS port to connect analog phone / fax machine to HT841/HT881 using RJ11 telephone cable.

FXO ports to be connected to physical PSTN line from a traditional PSTN PBX or PSTN Central O ce. HT841 supports 4 FXO ports and HT881 supports 8 FXO Ports.

Factory reset button. Press for 7 seconds to reset to factory default settings. Quick press will only reboot the unit.

PORTS DESCRIPTION

Note
HT841/HT881 supports switching the working mode of NET1 and NET2 on the Web User interface. The presence of the Triangle Icon alongside the NET1 port indicates that, by default, NET1 serves as the WAN port.

CONNECTING THE HT841/HT881
The HT841/HT881 can be connected either via NET 1 port (DHCP client) or via NET 2 port (DHCP Server):

Connecting the HT841/HT881 using NET 1 port
1. Insert a standard RJ11 telephone cable into FXS port and connect the other end of the telephone cable to a standard touch-tone analog telephone.

HT841/HT881 – Quick Installation Guide

2/5

6/25/24, 11:30 AM

HT841/HT881 – Quick Installation Guide – Documentation Center

2. Connect the NET 1 port of the HT841/HT881 to a router, switch or modem using an

Ethernet cable.

3. Insert the power adapter into the HT841/HT881 and connect it to a wall outlet and make sure to respect the technical speci cations of the power adapter used.

4. Power, NET 1, FXO and FXS LED will be solidly lit when the HT841/HT881 is ready for use.

Connecting the HT841/HT881 using NET 2 Port
1. Insert a standard RJ11 telephone cable into FXS port and connect the other end of the telephone cable to a standard touch-tone analog telephone.
2. Connect a computer or switch to the NET 2 port of the HT841/HT881 using an Ethernet Cable.
3. Insert the power adapter into the HT841/HT881 and connect it to a wall outlet and make sure to respect the technical speci cations of the power adapter used. If PoE switch is used in step 2, this step could be skipped.
4. Power, NET 2 and FXS, and FXO LED will be solidly lit when the HT841/HT881 is ready for use.

CONFIGURING THE HT841/HT881

Configure via IVR Menu
1. Use an analog telephone connected to FXS port of your HT841/HT881. 2. Press ** (press the star key three times) to access the IVR menu and wait until you hear
“Enter the menu option “. 3. Follow IVR Menu options to con gure your HT841/HT881. Move to next option by
pressing
or press # to go to main menu.

Note: To obtain IP address, press 02 and the current IP address will be announced.

Configure using Web UI
1. Connect the computer to the same network as your HT841/HT881 and make sure the HT841/HT881 is booted up.
2. You may check your HT841/HT881 IP address using the IVR on the con-nected phone. 3. Open the Web browser on your computer. 4. Enter the HT841/HT881’s IP address in the address bar of the browser. 5. Enter the administrator’s password to access the Web Con guration Menu.(By default
the admin password is found on a sticker on the back of the unit ).

HT841/HT881 – Quick Installation Guide

3/5

6/25/24, 11:30 AM

HT841/HT881 – Quick Installation Guide – Documentation Center

U.S. FCC Part 15 Regulatory Information
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Any Changes or modi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

CAN ICES-003(B) / NMB-003(B)

If trouble is experienced with this equipment, please contact (Agent in the US):

Company Name: Grandstream Networks, Inc.

Address: 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA

Tel: 1-617-5669300

Fax: 1-617-2491987

Refer to online documents and FAQ for more detailed information: http://www.grandstream.com/our-products

For Certi cation, Warranty, and RMA information, please visit www.grandstream.com
Please download the user manual and FAQ for more detailed con guration instructions: https://www.grandstream.com/our-products

Need Support?

Can’t nd the answer you’re looking for? Don’t worry we’re here to help!

HT841/HT881 – Quick Installation Guide

4/5

6/25/24, 11:30 AM
CONTACT SUPPORT

HT841/HT881 – Quick Installation Guide – Documentation Center

HT841/HT881 – Quick Installation Guide

5/5

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GRANDSTREAM User Manuals

Related Manuals