MEAN WELL LPF-90-36 Constant Voltage Plus Constant Current LED Driver Owner’s Manual
- July 30, 2024
- MEAN WELL
Table of Contents
90W Constant Voltage + Constant Current LED Driver
LPF – 90 series
Features
- Constant Voltage + Constant Current mode output
- Plastic housing with Class II design
- Built-in active PFC function
- Class 2 power unit
- Fully encapsulated with IP67 level
- Typical lifetime>50000 hours
- 5 years warranty
Applications
- LED panel lighting
- LED downlight
- LED decorative lighting
- LED tunnel lighting
- Moving sign
- Type “HL” for use in Class I, Division 2 hazardous (Classified) location.
GTIN CODE
MW Search:
https://www.meanwell.com’serviceGTIN.aspx
Description
LPF-90 series is a 90W AC/DC LED driver featuring the dual modes constant voltage and constant current output. LPF-90 operates from 90~305VAC and offers models with different rated voltage ranging between 15V and 54V. Thanks to the hign efficiency up to 91%, with the fanless design, the entire series is able to operate for -40°C ~ +70°C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations.
Model Encoding
SPECIFICATION
MODEL| LPF-90-15| LPF-90-20| LPF-90-24| LPF-90-30|
LPF-90-36| LPF-90-42| LPF-90-48| LPF-90-54
---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
CONSTANT CURRENT REGION Note.2| 9 ~ 15V| 12 ~ 20V| 14.4 ~ 24V| 18 ~ 30V| 21.6
~ 36V| 25.2 ~ 42V| 28.8 ~ 48V| 32.4 ~ 54V
RATED CURRENT| 5A| 4.5A| 3.75A| 3A| 2.5A| 2.15A| 1.88A| 1.67A
RATED POWER Note.5| 75W| 90W| 90W| 90W| 90W| 90.3W| 90.24W| 90.18W
RIPPLE & NOISE (max.) Note.3| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p|
200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.4| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%|
±4.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.5%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.6| 1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC
INPUT| VOLTAGE RANGE Note.5| 90 ~ 305VAC 127 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.96/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@load¾60%/115VC,230VAC; @load¾75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.)| 89%| 90%| 90.5%| 91%| 91%| 91%| 91%| 91%
AC CURRENT| 0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=435μs measured at 50% Ipeak) at
230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 4 units (circuit breaker of type B) /
6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION| OVER CURRENT| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is
removed
OVER VOLTAGE| 18 ~ 21V| 23 ~ 27V| 28 ~ 34V| 34 ~ 38V| 41 ~ 46V| 47 ~ 53V| 54 ~
60V| 59 ~ 65V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +70℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+70℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z
axes
SAFETY & EMC| SAFETY STANDARDS Note.8| UL8750(type”HL”), CSA C22.2
No.250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS
EN/EN62384, J61347-1, J61347-2-13, EAC TP TC 004, GB19510.1,GB19510.14,IP67
approved ; Design refer to UL60950-1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Note.8| Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C
(@load≧60%) ; BS EN/EN61000-3-3, GB/T 17743 , GB17625.1,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547,
light industry level (surge immunity Line-Line 2KV),EAC TP TC 020
OTHERS| MTBF| 3292.9K hrs min. Telcordia SR-332 (Bellcore) ; 301.7Khrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1616136mm (LWH)
PACKING| 0.7Kg;20pcs/15Kg/0.73CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input,
rated current and 25℃ of ambient temperature.
2. Please refer to “DRIVING METHODS OF LED MODULE”.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load
regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC
CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the
driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in
combination with final equipment. Since EMC performance will be affected by
the complete installation, the final equipment manufacturers must re-qualify
EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
8. To fulfill requirements of the latest ErP regulation for lighting
fixtures, this LED driver can only be used behind a switch without permanently
connected to the mains.
9. This series meets the typical life expectancy of >50,000 hours of
operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or
less.
10. Please refer to the warranty statement on MEAN WELL’s website at
http://www.meanwell.com
11. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
10. For any application note and IP water proof function installation
caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
※ This series is able to work in either Constant Current mode (a direct drive
way) or Constant Voltage mode (usually through additional DC/DC driver) to
drive the LEDs.
OUT PUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
※ 48V Model, Tcase at 60℃
EFFICIENCY vs LOAD
LPF-90 series possess superior working efficiency that up to 91% can be
reached in field applications.
※ 48V Model, Tcase at 60℃
LIFE TIME
MECHANICAL SPECIFICATION
Recommend Mounting Direction
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
http://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>