profi-pumpe DPS01150-6 Highly Flammable Chemicals Instruction Manual
- July 25, 2024
- profi-Pumpe
Table of Contents
- profi-pumpe DPS01150-6 Highly Flammable Chemicals
- Product Usage Instructions
- Frequently Asked Questions
- SAFETY INSTRUCTION AND WARNINGS
- INTRODUCTION
- OPERATION
- Installation of the barrel pump
- SECURITY TIPS
- SERVICING
- GUARANTEE REGULATIONS
- TECHNICAL DATA
- SPARE PARTS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
profi-pumpe DPS01150-6 Highly Flammable Chemicals
Specifications:
- Model: DIESEL 230V FASS-PUMPE SET 2.2 (DPS01150-6)
- Power: 230V
- Application: Pumping diesel or fuel oil ONLY
- Not suitable for: Gasoline, kerosene, or ignitable liquids
- Usage: Indoor, well-ventilated areas
Product Usage Instructions
Safety Instructions:
- Read the user manual before use
- Use protective gloves
- Avoid contact with rain and moisture
- Avoid open flames or sources of ignition
Installation:
- Connect all parts correctly
- Ensure outlet connections are properly placed
- Plug the power cord into a power source
- Turn on the pump using the on/off switch
Operation:
- Adjust flow with the regulating screw on the handle
- Refuel as usual
- Return the nozzle to storage position and turn off the pump after refueling
Frequently Asked Questions
- Q: Can I use this pump for gasoline?
- A: No, this pump is only suitable for pumping diesel or fuel oil. Do not use it for gasoline or other ignitable liquids.
- Q: What should I do if the pump is not working?
- A: Check the electrical connections, ensure proper cooling, and refer to the troubleshooting section of the user manual. If issues persist, contact customer support.
- Q: How do I clean and maintain the pump?
- A: Follow the cleaning instructions in the user manual. Regular \maintenance includes checking for leaks, ensuring proper electrical connections, and keeping the pump free from debris.
FASS-PUMPE SET
MODELL AUF ANFRAGE!
Technical changes, misprints and mistakes reserved! Newest information about our products can be found online. Technische Änderungen, Druckfehler und Irrtümer vorbehalten! Aktuelle Informationen zu unseren Produkten finden Sie auf:
SAFETY INSTRUCTION AND WARNINGS
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why functional security and operational safety stands on first place for us.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage. Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them.
IN GENERAL
The barrel pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls – each pump is checked individually – rests of the check-fluid could be still inside the pump or on the package. The counter (if available) shows more than 0,0 Liter because of that (usually 5-12L). The pumps were optimized by us in particular for their special demands. Make sure after unpacking the pump that the data given on the type label agree with the operating conditions. In the case of doubt the pump is not to be used. Transport damages are immediate to be reported to the package distrib utor and to us in witten form. By transport with DHL please contact your local DHL office within 7 days.
RANGES OF APPLICATION
These diesel pumps are made for pumping diesel or fuel oil ONLY!
IMPORTANT
They are not suitable for pumping ignitable liquids like gasoline, kerosene, or for pumping at places where the danger of an explosion exists. When using the pump, make sure there are no open flames, lighters, matches, cigarettes or similar things present around you. When operating suitable protective gloves must be worn. These pumps are made for pumping clean diesel/biodiesel or fuel oil ONLY! The pumped liquid should not contain abrasive components. Abrasive components reduces pump life.
OPERATION
The installation must be performed by a qualified professional. Please, check each time before using, the electrical connections and the cables are not damaged. Also, it is NOT recommended to perform, for example, a cable extension. It is not certain whether this modification is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during prolonged operation. Diesel pumps are electrical products, which have to be protected against outer influences, f.e. caused by weather. Only use the pump in well-ventilated rooms and areas with enough fresh air. The floor, on which the pump may be used, should be flat. Please keep enough space from walls. The specified suction lift is the maximum suction at optimal conditions. Do not reduce the cross area of suction and discharge lines.
CAUTION: Do not connect more than 4m of 1“ hose on the pressure side. For smaller hose diameters, use shorter hose. Operation with dispensing guns is not recommended and is therefore at your own risk. These measures must be strictly adhered to in order to avoid damage to the pump
Installation of the barrel pump
- Connect all parts correctly and ensure outlet connections are in proper placement.
- Apply power cord to the motor by plugging the power cord into a power source. Turn on the pump by use the on/off switch. The flow of the 230 volt pump can be adjusted with the flow regulating screw on the handle.
- Refuel as usual.
- When fueling is complete, return the nozzle to its storage position and turn off the pump.
ADJUSTABLE PUMP OUTPUT WITH THE DIESEL 230V BARREL PUMP SET 2.2 POWER
The pump version 2.2 Power has a rotary control in the handle that allows you to quickly and easily limit the maximum speed. If the control is fully turned up, the diesel drum pump develops its full power with maximum flow. If the control knob is turned down, the speed and thus also the flow rate of the pump is reduced/limited. The pump also has a small push button on the side of the handle which you can use to lock the main switch with the rotary control. If the lock is engaged, the diesel drum pump continues to pump until you release the lock by pressingthe push button again
ATTENTION!
SECURITY TIPS
- Do not leave the motor running, when not in operation.
- Clean the fuel strainer regularly.
- Obey absolutely valid regulations on the electrical security
- When operating suitable protective gloves must be worn.
- Never run pump dry
- Never run pump against pressure
- Pumping inflammable, as well as all other aggressive liquids, except of diesel or fuel oil, is prohibited
- Never pump liquid food products
- Before usage, check on the tightness of the hose clamps
- Pay attention to the max. liquid temperature of 35°C
- Never pull the pump on the electrical cable or pressure hose
- Disconnect the plug immediately from the power grid when the line has been damaged or severed
- Switch off pump immediately after usage
- Don’t move the pump in any way, while it’s running
- During longer unused times, clean the pump, wash it out with diesel or fuel oil, dry and store it at room temperature
- ALWAYS supervise and watch the pump, while using
- The electrical connections are always to be carried out by an authorised professional
- Operation can not be performed by children and young people under 16 and people with intellectual disabilities
- The pump must be protected from rain and moisture. The pump may only be operated in dry rooms. The ingress of water into the energized components of the pump increases the risk of electric shock
- If you do not intend to use the pump for an extended period of time, drain the fluid from the the pump, flush it out with diesel/heating oil and store it dry at room temperature
- Pumping of liquids other than diesel or fuel oil is prohibited
AdBlue® can not be mixed with diesel, because the chemical is injected from a separate tank into the exhaust system. Where ammonia is released, which reacts with the nitrogen oxides in the catalyst and converts to nitrogen and water vapor AdBlue® consists of 32.5% urea and 67.5 of demineralized water. AdBlue®* is odorless and non-toxic, not flammable, explosive or dangerous for the environment.
THE MANUFACTURER EXPLAINS:
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this user manual.
- To reject every responsibility for the damages which originate from the improper use of the pump
SERVICING
Under normal pumping conditions the pump requires no servicing.
But it is important to keep the suctions and delivery sections perfectly clean
and free from all clogging.
The following controls should be carried out regularly:
- Intactness of the electric cable
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
Moreover, the pump should be emptied at risk of frost, be washed out with diesel/fuel oil and stored dry.
GUARANTEE REGULATIONS
For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall not be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi-pumpe.de/service.php. We will inform you how to proceed with case-related. Please mark returns sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before destination. We provide our service in Germany.
The warranty does not cover:
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by selffault
- Improper servicing and improper use
- DRY RUNNING (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING OF MISTAKES
Problem | Possible causes | Solutions |
---|
The pump won’t start
| No power supply| Check the clamps and safety devices
Impeller jammed| Check for signs of damage and clogging. Reassemble.
Motor malfunction| Contact your dealer.
The suction of the pump is not working| Leak in suction lines or connections|
Check the suction pipe and all connections for tightness. Fill the suction
hose and the pump. Suction hose must be laid in a con- stantly rising so that
air bubbles can escape towards the pump
Reduced flow
| Tank liquid level too low.| Fill up the tank.
By-pass valve jammed| Clean and re-assemble
Air in the suction tube| Make sure that the suction tube is not damaged
Filter clogged| Clean the filter.
Leakage of Diesel oil.| Check the connectors and gaskets.
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth. THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely DIESEL 230V FASS-PUMPE SET 2.2, DIESEL 230V FASS-PUMPE SET 2.2 POWER as placed onthe market, complies with the relevant provisions listed below, the relevant EU harmonized directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer. The sole authorised person to keep the technical documents: Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Low Voltage Directive (2014/35/EU) EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards:
EN IEC 61326-1:2021, EN 55011:2016+A2:2021, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021 Signed for and on behalf of:
Amur S.à r.l.
Remich, 21.02.2024
i.V. Dipl. Phys. Peter Neumüller Technical Manager
TECHNICAL DATA
| DIESEL – 230V FASS- PUMPE SET 2.2 (DPS01150-6)| DIESEL – 230V FASS-
PUMPE SET 2.2 POWER (DPS01141-6)
---|---|---
Power| 600 Watt| 1300 Watt
Max. pump rate (Qmax)| 60 l/min| 75 l/min
Max. Flow height (Hmax)| 12 m| 15 m
Engine speed / Rotated / minute| tba / folgt| tba / folgt
Rated voltage| 230V| 230V
Connection hose| 25 mm| 25 mm
Protection grade| IPX4| IPX4
Suction tube (length)| ca. 90cm| ca. 90cm
Suction tube (diameter)| ca. 40mm| ca. 40mm
Dimensions (l/w/h)| 126x8x9 cm| 126x8x9 cm
Weight (in kg)| 3,1 kg| 3,9kg
Fluid media| Diesel, Heizöl (Fuel oil)| Diesel, Heizöl (Fuel oil)
All products listet in this manual are Made in PRC
At the time of printing this manual, the specifications were not available completely
SPARE PARTS
The spare parts will be available for purchase from AMUR S.à.r.l. at www .profi-pumpe.de
Amur S.à r.l.
- www.amur.lu
- Email: info@amur.lu
- Tel.: +49 611 9458777-0
- Fax: +49 611 9458777-11
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>