TELTONIKA FMB206 Wiki Knowledge Base Instructions

July 23, 2024
teltonika

TELTONIKA FMB206 Wiki Knowledge Base Instructions
TELTONIKA FMB206 Wiki Knowledge Base Instructions

FMB206 Manual > FMB206 General description

FMB206 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.

Package contents

The FMB206 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:

  • FMB206 device with case and wires;
  • USB cable (optional);
  • Integrated Ni-MH battery 7.2V, 400mAh for FMB206 device;

Basic characteristics
GSM/GPRS/GNSS features:

  • Teltonika TM2500 quad band module (GSM 850/900/1800/1900 MHz);
  • GPRS Multi-Slot class 12 (Up to 85,6 kbps);
  • SMS (text, data);
  • Integrated GNSS receiver;
  • Up to 165 dBm GNSS receiver sensitivity.

Hardware features:

  • 128 MB internal Flash memory (422 400 Records);
  • Built-in movement sensor;
  • Integrated Ni-MH battery 7.2V, 400mAh for FMB206 device;
  • Internal High Gain GSM antenna;
  • External High Gain GNSS antenna;

The Interface features:

  • Power supply : 6 … 30V;
  • USB port;
  • 3 digital inputs;
  • 1 analog input;
  • 2 open collector digital outputs (connecting external relays, LED’s, buzzers etc.);
  • 1Wire® temperature sensor;
  • 1Wire® i Button;
  • 2 LED’s indicating device status.

Special features:

  • High Quality track even in high density urban canyon;
  • Ready for harsh environment;
  • Any element event triggers (external sensor, input, speed, temperature, etc.);
  • Highly configurable data acquisition and sending;
  • Multiple Geo-fence areas;
  • Sleep mode;
  • Deep sleep mode;
  • Configurable scenarios available;
  • Real-time process monitoring;
  • Authorized number list for remote access;
  • Firmware update over GPRS or USB port;
  • Configuration update over GPRS, SMS or USB port;
  • TCP/IP or UDP/IP protocol support;
  • 500000 record storing;

  • Overvoltage protection.
Description Voltage Duration
Normal operation +6 … +30 Unlimited
Protection turns on, device turns off 34 V Unlimited
Maximum voltage < 70 V Unlimited
Maximum voltage impulse 120 V 10 MS

Technical features

Part name Physical specification
Navigation indication LED
Modem indication LED
USB Mini USB socket
GNSS Mini USB socked External GNSS antenna
GSM Internal GSM antenna

Technical details

Power supply 6…30V DC 1.5 W max. device consumption Energy consumption at 12 V:| GPRS: average 33.5 mA r.m.s;
Nominal: average 250 mA; GPS Sleep: average 11.6 mA; Online Sleep: average 4.0 mA; Deep Sleep: average 3.7 mA; Ultra Sleep: average 1.9 mA
---|---
FMB206 Battery charge current| max. 80 mA
Operating temperature (without battery) –| -40..+85 °C
Storage temperature (without battery)| 40..+85 °C
Storage relative humidity| 5..95% (no condensation)

Dimension drawing:
Dimension drawing:

Technical information about internal battery

Internal back-up battery :Battery voltage (V):Nominal capacity (mAh) :Power (Wh):Charging temperature (°C)

Ni-MH Prismatic Battery pack: 7.2 ~ 7.5: 400 :2.95 – 3.07 :0 – 50

Batteries are covered by 6 month warranty support.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
**** Battery should not be disposed of into general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.

Electrical characteristics

Characteristic description: Value Min. Typ. Max. Unit

Supply Voltage:
Supply Voltage
(Recommended Operating Conditions) :6 30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF)  Drain current:120 µA
(Digital Output ON, Recommended Operating Conditions) :0.1 0.5 A
Static Drain-Source resistance (Digital Output ON):120 mΩ\
Digital Input:
Input resistance (DIN1) 59.9 kΩ
Input resistance (DIN2, DIN3) 67.5 kΩ
Input voltage
(Recommended Operating Conditions) ;0 60 V
Input Voltage threshold (DIN1) : 4 4 8 V
Input Voltage threshold (DIN2, DIN3) : 2.5 2.7 3 V
Analog Input:
Input voltage
( Recommended Operating Conditions), Range : 1 0 10 V
Input resistance, Range 1 :120 kΩ
Input voltage
(Recommended Operating Conditions), Range 2 :0 30 V
Input resistance, Range : 2 146.7 kΩ
Output Supply Voltage : 1-Wire:
Supply voltage :3.8 V
Output inner resistance :450 600 mΩ
Output current (Uout > 3.0 V) :75 mA
Short circuit current (Uout = 0) :75 mA

**** Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Supply Voltage -32
Absolute Maximum Ratings)

Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (I drain = 2 mA)| | | +36 V
Digital Input Voltage (Absolute Maximum Ratings)| 32| | +32 V
Analog Input Voltage (Absolute Maximum Ratings)| | -32| +32 V

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals