Feature
- MEANWELL Patent Number:ZL202220241473.0
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit/Overload/Over voltage / Over temperature
- Forced air cooling
- Built-in cooling Fan ON-OFF control
- 1U low profile
- Withstand 5G vibration test
- High operating temperature up to 65°C
- Operating altitude up to 5000 meters (Note.10)
-
- 3 years warranty
- MTBF>1KK hrs
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment’s or apparatus
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
LRS-600 series is a 600W single-output enclosed type power supply with 41mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 27V, 36V and 48V.In addition to the high efficiency up to 92%, with the built-in long life fan LRS-600 can work under-20~+65°C with full load. LRS-600 has the complete protection functions and 5G anti-vibration capability: It is complied with complete international safety regulations. LRS-600 series serves as a high price-to-performance power supply solution for various industrial applications.
Model Encoding
SPECIFICATION
MODEL| LRS-600-5| LRS-600-12| LRS-600-15| LRS-600-24|
LRS-600-27| LRS-600-36| LRS-600-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 36V| 48V
RATED CURRENT| 100A| 50A| 40A| 25A| 22.2A| 16.6A| 12.5A
CURRENT RANGE| 0 ~ 100A| 0 ~ 50A| 0 ~ 40A| 0 ~ 25A| 0 ~ 22.2A| 0 ~
16.6A| 0 ~ 12.5A
RATED POWER| 500W| 600W| 600W| 600W| 599.4W| 597.6W| 600W
RIPPLE & NOISE (max.) Note.2| 200mVp-p| 200mVp-p| 200mVp-p|
240mVp-p| 270mVp-p| 360mVp-p| 360mVp-p
VOLTAGE ADJ. RANGE Note.3| 4.75 ~ 5.5V| 11.4 ~ 13.2V| 14.25 ~ 16.5V|
22.8 ~ 26.4V| 25.65 ~ 29.7V| 34.2 ~ 39.6V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.4| ±2.0%| ±1.5%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION **Note.5| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%| ±0.5%
LOAD REGULATION Note.6| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
SETUP, RISE TIME Note.7| 1300ms, 50ms/230VAC
1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)| 20ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE ****Note.8| 90 ~ 132VAC / 180 ~ 264VAC by
switch 255 ~ 370VDC (swith on 230VAC)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 86%| 90%| 90%| 91%| 91%| 92%| 92%
AC CURRENT (Typ.)| 12A/115VAC 7.5A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC 60A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION (Note.9)| OVER LOAD| 105 ~ 150% rated output power
Constant current limiting, unit will shutdown after 3 sec. re-power on to
recover
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18 ~ 21V| 27.6 ~ 32.4V| 31 ~
36.5V| 41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
FUNCTION| FAN ON/OFF CONTROL (Typ.)| RTH3≧50℃ FAN ON, ≦40℃ FAN
OFF
ENVIRONMENT| WORKING TEMP.| -20 ~ +65℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ: According to EN61558, EN50178, EN60664-1,
EN62477-1; altitude up to 2000 meters
SAFETY| ****SAFETY STANDARDS| BS IEC/UL 62368-1, EAC TP TC 004,
KC62368-1(except for 5V), BIS IS13252(Part1):2010/IEC60950-1: 2005(NOTE
13),BSMI CNS15598-1,GB 4943.1,BS EN/EN61558-1,BS EN/EN61558-2-16 approved,
Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to EAC TP TC 020, BSMI CNS15936,KC KSC 9832,
KSC 9835
EMC IMMUNITY| Compliance to EAC TP TC 020,KC KSC 9832, KSC 9835
OTHERS| MTBF| 1533.4K hrs min. Telcordia SR-332(Bellcore) ;
301.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 22512441mm (LWH)
PACKING| 0.95Kg/12pcs/12.4Kg/0.77CUFT
NOTE**|
- A parameters NOT speciay mentioned are measured at 230VAC input,rated oad and 25℃ of ambient temperature.
- Rippe & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parae capacitor.
- Votage adjustment can ony be operated within the input range of 100~120VAC or 200-240VAC. If the votage adjustment is performed outside this range, it may cause abnorma output.
- Toerance : incudes set up toerance, ine reguation and oad reguation.
- Line reguation is measured from ow ine to high ine at rated oad.
- Load reguation is measured from 0% to 100% rated oad.
- Length of set up time is measured at cod start. Turning the power suppy on/off frequenty may ead to increase of the set up time.
- Derating may be needed under ow input votages. Pease refer to”Static Characteristics” sections for detais.
- Once protections are triggered, 4min(Typ.) of cod down time is required before restart.
- The ambient temperature derating of 5℃/1000m is needed for operating atitude greater than 2000m(6500ft).
- This power suppy does not meet the harmonic current requirements outined by EN61000-3-2. Pease do not use this power suppy under the foowing conditions:a) the end-devices is used within the European Union, andb) the end-devices is connected to pubic mains suppy with 220Vac or greater rated nomina votage, andc) the power suppy is:- instaed in end-devices with average or continuous input power greater than 75W, or- beong to part of a ighting system Exception:Power suppies used within the foowing end-devices do not need to fufi EN61000-3-2a) professiona equipment with a tota rated input power greater than 1000W;b) symmetricay controed heating eements with a rated power ess than or equa to 200W12. RCM is on vountary basis and meets reevant IEC or AS/NZS standards compying with AS/NZS 4417.1.13. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.※ Product Liabiity Discaimer:For detaied information, pease refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
Derating Curve
AMBIENT TEMPERATURE (℃)
Static Characteristics
INPUT VOLTAGE (VAC) 60Hz
Note: Due to the test method difference, the rating on label differ from
derating curve as follow.
For 5V model, the output current states 100A on label when input voltage >
110Vac, and states 90A when input voltage < 110Vac, please refer to label for
detail
Documents / Resources
| MEAN
WELL LRS-600-5 Single Output Switching Power
Supply
[pdf] Owner's Manual
LRS-600-5, LRS-600-12, LRS-600-15, LRS-600-24, LRS-600-27, LRS-600-36,
LRS-600-5 Single Output Switching Power Supply, LRS-600-5, Single Output
Switching Power Supply, Switching Power Supply, Power Supply
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>