OPTEX FLX-P-DT-X5 Flexible Range Indoor Detector Installation Guide

July 14, 2024
OPTEX

OPTEX-logo

OPTEX FLX-P-DT-X5 Flexible Range Indoor Detector

  1. Not certified to UL
  2. Not certified to UL, INSERT and EN 50131

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-1

Contents

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-2

Before installation

Manufacturer’s statement

Warning Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
Caution Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-3

Warning

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-4

Caution

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-5

Parts identifications

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-6

Installation

Disassemble

  1. Unlock the cover
  2. Open the cover
  3. Remove the main unit

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-7

Wall mount without bracket

  1. Wire through the base

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-8

Mount the base

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-9

NOTE
Mounting screws are not included.
Φ 3 mm screws are recommended.

Wall mount with bracket

  1. Wire and mount on the wall.
  2. Join the base on the bracket.
  3. Fix the base with the fixing screws (optional)

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-10

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-11

NOTE

  • Adjust the detection direction while jointing.
    Confirming with a walk test is required. –> Refer to “3-1. Walk test”

  • 2 fixing screws are required for the Grade 2 * and higher grade installation.

  • Not evaluated by UL.

Ceiling mount with bracket
How to change the bracket to the ceiling mounting

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-12

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-13

NOTE

  • Adjust the detection direction while jointing.
    Confirming with a walk test is required.
    –> Refer to “3-1. Walk test”

  • 2 fixing screws are required for the Grade 2 * and higher grade installation.

  • Not evaluated by UL.

Assemble and connect

  1. Attach the main unit to the base.
  2. Connect wires to the terminal.

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-14

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-15

Power cable length
The power cable should be limited to the following length.

FLX-P-ST
WIRE GAUGE| 12 V DC| 14 V DC| FLX-P-DT
WIRE GAUGE| 12 V DC| 14 V DC
---|---|---|---|---|---
AWG 22

(0.33 mm²)

| 520 m

(1,710 ft.)

| 1,130 m

(3, 718 ft.)

| AWG 22

(0.33 mm²)

| 410 m

(1,350 ft.)

| 890 m

(2,920 ft.)

AWG 20

(0.52 mm²)

AWG 18

(0.83 mm²)

| 820 m

(2,690 ft.)

| 1,790 m

(5,870 ft.)

| AWG 20

(0.52 mm²)

AWG 18

(0.83 mm²)

| 650 m

(2,130 ft.)

| 1,400 m

(4,590 ft.)

1,320 m

(4,330 ft.)

| 2,850 m

(9,350 ft.)

| 1,030 m

(3,380 ft.)

| 2,240 m

(7,350 ft.)

Settings

Wide/Narrow setting

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-16

NOTE Install the lens so that the letters on the cover and on the lens match your intention.

How to remove the lens

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-17

How to install the lens
Push the lens firmly at 3 points in numerical order.

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-18

Set the jumper pin to “Wide” or “Narrow”
Caution The jumper pin must be “Narrow”, when the lens is set to “Narrow”.

NOTE

  • Default setting is “Wide”.
  • When “Narrow” is selected, MW detection will be disabled.

Jumper pin settings

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-20

PEU settings

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-21

Walk test

  1. Confirm that the LED pin is “ON” , then close the cover.
  2. Walk in the detection area to check the detecting performance via LED indication.
  3. Return the LED pin to “OFF” after the walk test, if necessary.
  4. Lock the cover

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-22

NOTE Conduct a walk test at least once a year.

Specifications

Model FLX-P-ST FLX-P-DT-X5/-X8/-X9

Installation
Detection method| Passive infrared| Passive infrared and Microwave
Coverage| Wide:15 m (50 ft.) 85°/ Narrow:24 m (80 ft.) 5°

( No MW detection at “Narrow” setting )

Detection zones| Wide: 78 zones/ Narrow: 18 zones
Mounting height| 2.0 to 3.0 m (6’7″ to 9’8″)
Alarm period| 2.0 ± 0.5 s
Warm-up period| Approx. 60 s (LED blinks)
LED indicator| Switchable ON/OFF Green: [1] Warm-up [2] Alarm
Electrical
Power input| 9.5 to 16 V DC UL *
Current draw| 8 mA (normal)

11 mA (max.) at 12 V DC

| 11 mA (normal)

14 mA (max.) at 12 V DC


Relay output

| Alarm| N.C. 24 V DC 0.1 A max. (Resistive load)
Tamper| N.C. 24 V DC 0.1 A max. (Resistive load)

(Open when the cover is removed.)

Remote LED| Terminal: open = OFF 0 V = ON
Environmental
Operation temperature| -20℃ to +50℃(-4°F to +122°F)| -20℃ to +45℃(-4°F to +113°F)
Temperature compensation| Digital (SMDA)
Environmental humidity| 95% max.
RF interference| No alarm 10 V/m
Mechanical
Dimension| H: 129.2 x W: 61.5 x D: 50.9 mm (H: 5.09″ x W: 2.42″ x D: 2.00″)
Weight| Approx. 95 g (3.35 oz)

(with Bracket : Approx. 125 g (4.41 oz))

| Approx. 110 g (3.88 oz)

(with Bracket : Approx. 140 g (4.94 oz))

Mounting| Wall, Corner (Indoor)

(with Bracket : Wall, Corner, Ceiling)

  • Specifications and designs are subject to change without prior notice.
  • These units are designed to detect an intruder and activate an alarm control panel.
    Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.

**UL *** Shall be powered via a UL listed burglar alarm class 2 output power limited power supply that has a min standby power of 4 hrs.

Dimensions

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-23

Detection area

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-24

NOTE

  • The * 2.4 m dotted line indicates the recommended mounting height.
  • When “Narrow” is selected at the jumper pin, MW detection will be stopped.

Angle adjustment with bracket CW-G2

OPTEX-FLX-P-DT-X5-Flexible-Range-Indoor-Detector-25

Compliance

RE Directive 2014/53/EU

  • OPTEX declares that FLX-P-DT-X5, FLX-P-DT-X8, and FLX-P-DT-X9 comply with RE Directive 2014/53/EU. Doc documents can be found on our website; optex.net
  • Microwave emission Frequency and Power

FLX-P-DT-X5: 10.525 GHz  15.78 mW e.i.r.p
FLX-P-DT-X8: 10.587 GHz       8.93 mW e.i.r.p
FLX-P-DT-X9:  9.425 GHz  14.50 mW e.i.r.p

  • The following list indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency.

10.525 GHz: Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg, The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
10.587 GHz: Belgium, France, Germany, Ireland, Luxembourg, The Netherlands, United Kingdom
9.425 GHz: Austria, Czechia, Estonia, Germany, Slovakia, Turkey, Russia

  • FLX-P-DT-X5, FLX-P-DT-X8 and FLX-P-DT-X9 also comply with EU radiation exposure limits set forth for an uncontrolled This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

UK Radio Equipment Regulations 2017

  • FLX-P-DT-X8 also comply with UK radiation exposure limits set forth for an uncontrolled environment.
    This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

  • Hereby, OPTEX declares that the radio equipment type FLX-P-DT-X8 is in compliance with Radio Equipment Regulations The full text of the UK declaration of conformity is available at the following internet address: www.optex.net

FCC/IC

  • This device complies with Part 15 of the FCC Operation is subject to the following two conditions:
    • This device may not cause harmful interference, and
    • This device must accept any interference received, including interference that may cause undesired
  • This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
    • This device may not cause
    • This device must accept any interference, including interference that may cause undesired operation of the device

EN 50131-1 Grades and Environmental Class; Security Grade 2, Environmental Class II
Applied Standards; EN 50131-2-2 (FLX-P-ST), EN 50131-2-4 (FLX-P-DT-X5 and FLX-P-DT-X8)
Tested and certified by Telefication
larm klass 2, miljö klass II, SSF 1014
PD6662:2017
UL/c-UL listed (FLX-P-ST and FLX-P-DT-X5)

EU & UK contact information
https://navi.optex.net/cert/contact/

OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com

OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com

OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals