ELKO ep TEV-1 Thermostat Owner’s Manual

July 16, 2024
ELKO ep

ELKO ep TEV-1 Thermostat Owner’s Manual

ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Česká republika
Tel.: +420 573 514 211
e-mail: elko@elkoep.cz
www.elkoep.cz

Made in Czech Republic

FIG 1.JPG

Characteristics

  • two-level thermostat with function “WINDOW” meaning that output is switched in case the measured temperature is within set range (adjustable in range -20.. +20 °C / -4 °F to +68 °F)
  • used as protection against freezing (water-shoots, pavements, drives, pipes, etc.) heating is on when temperature falls under set upper level (e.g. +5 °C / +41 °F) and off in case it falls under lower level (e.g. -10 °C / 14 °F, when heating is not able eff ectively operate)
  • thermostat is placed in water-proof box with IP65, which allows installation outside, with in-built sensor TZ-0 (included in the supply)
  • thermostat status is indicated by LED (3colours) under transparent cover
  • function monitoring short-circuit and sensor disconnection (break)
  • output changeover contact 16 A / SPDT (AC1)

Description

FIG 2 Description.JPG

Symbol

FIG 3 Symbol.JPG

Connection

FIG 4 Connection.JPG

FIG 5 Connection.JPG

FIG 6.JPG

Technical parameters

TEV-1

Temperature sensor

τ65 (95): time, which sensor needs to heat up on 65 (95) % of ambient temperature of environment, in which is located.

Resistive values of sensors in dependance on temperature

Function

h) hysteresis
TEV-1 is a double thermostat designated for system of protection of roof watershoots against freezing. The device is placed in a waterproof box (IP65), sensor with double insulation, which is a part of the device, senses ambientrature. The device operates as zonal thermostata with independent setting of upper and bottom operational temperature. In case the ambient temperature is higher than T1 (upper temperature), thermostat switches heating of watershoots off (icing melts down). In case the ambient temperature is lower than T2 (bottom temperature),thermostat also switches heating off (to big freezing heating cannot manage to melt the ice).

Warning

Technical parameters Function
The device is constructed to be connected into 1-phase main and must be installed in accordance with regulations and norms applicable in a particular country. Installation, connection and setting can be done only by a person with an adequate electro-technical qualification which has read and understood this instruction manual and product functions. The device contains protections against over-voltage peaks and disturbing elements in the supply main. Too ensure correct function of these protection elements it is necessary to front- end other protective elements of higher degree (A, B, C) and screening of disturbances of switched devices (contactors, motors, inductive load etc.) as it is stated in a standard. Before you start with installation, make sure that the device is not energized and that the main switch is OFF. Do not install the device to the sources of excessive electromagnetic disturbances. By correct installation, ensure good air circulation so the maximal allowed operational temperature is not exceeded in case of permanent operation and higher ambient temperature. While installing the device use screwdriver width approx. 2 mm. Keep in mind that this device is fully electronic while installing. Correct function of the device is also depended on transportation, storing and handling. In case you notice any signs of damage, deformation, malfunction or missing piece, do not install this device and claim it at the seller. After operational life treat the product as electronic waste.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals